Spectral Measurements of Thin Films
With the tris dialyzed samples we recorded spectral data to show that the films being spun were truly 'thin film' and we demonstrated the ability of the thin films to change colour upon breathing by recording video and spectral data when breathed upon under the microscope.
Single Layer Spectra
Looking at this we can see that by breathing we have been able to shift the colour of the film from blue to yellow. The presence of one dominant peak is an indication of the thickness of the film as we are only seeing one constructive interference determined by the dominant peak.
Double Layer Spectra
This spectra was captured from a double layer with first layer PDMS, 2nd layer reflectin. You can see from the photos that this film is much thicker than before with multiple maxima and minima where the maxima indicate constructive interference and minima indicating destructive interference. The major difference between the two layer and three layer films is primarily there is a greater shift in wavelength because there is no hydrophobic PDMS layer on top preventing swelling of the reflectin layer. We show in the PDMS control that the hydrophobic PDMS does not swell under breathing. Therefore colouration changes in multilayers are all due to reflectin.
Triple Layer Spectra
PDMS Control