Preparation of electrocompetent cells
Overview
We use a protocol commonly used in our host lab provided by Diewertje Piebes.
Materials
- Detergent-free, sterile glassware and plasticware. We use dedicated centrifuge tubes that are only used for preparation of competent cells
- Table-top OD600nm spectrophotometer
- SOB WITHOUT MgCl
Procedure
- Prepare TOP10 preculture by inoculating 3ml of LB medium with a -80°C TOP10 glycerol stock into and shake overnight at 37°C
- Inoculate 200 ml of SOB containing no magnesium with 3 ml of preculture and grow in a 37°C shaker to an OD600 of 0.6-0.8
- please not that E. coli growth rate is significantly reduced due to the absence of Magnesium