Team:ETH Zurich/Modeling/SingleCell

From 2011.igem.org

(Difference between revisions)
(Parameter sweeps)
(Band Detector)
Line 27: Line 27:
-
We simulated the model for 5000s and for various concentrations of acetaldehyde. In the following figure you can see how the steady state concentration of GFP changes for different input concentrations of acetaldehyde. The band is formed when the acetaldehyde concentration is approximately in the range of 500-1500 microMolars.  
+
We simulated the model for 5000s and for various concentrations of acetaldehyde. In the following figure you can see how the steady state concentration of GFP changes for different input concentrations of acetaldehyde. The band is formed when the acetaldehyde concentration is approximately in the range of 500-1500 microMolars. The peak of the GFP pulse is observed when the acetaldehyde concentration is 1000 microMolars.
[[File:AcABandpass.png|600px|center]]
[[File:AcABandpass.png|600px|center]]
-
The peak of the GFP pulse is observed when the acetaldehyde concentration is 1000 microMolars.
 
==Sensitivity Analysis==
==Sensitivity Analysis==

Revision as of 14:12, 9 September 2011

Menu image preload Menu image preload Menu image preload Menu image preload Menu image preload Menu image preload


Single cell model

Brief overview of the model

The model of our system consists of two connected modules: the band detector and the filter. The band detector produces green fluorescent protein upon a detection of a certain range (band) of acetaldehyde concentration. After acetaldehyde concentration passes a certain threshold the filter turns the system red (red fluorescent protein is expressed).

Acetaldehyde from the smoke binds to AlcR and the formed complex then inhibits TetR. TetR inhibits LacI and CI. CI also inhibits LacI which inhibits GFP. This part of the circuit makes up the band detector. The Acetaldehyde-AlcR complex is considered as constant input to our system. By simulating with varying acetaldehyde concentrations we can see at which concentration is the band , i.e. at which concentrations GFP is produced. The connection to the filter is established via the LuxI inbition by CI. LuxI in turn produces AHL, which is described in our model as two states (AHL external and AHL internal). AHL diffuses in and out of the cell and after binding of AHL internal to LuxR, the complex R is created. In the model the LuxR concentration is taken as a parameter since it does not vary with time. Finally, RFP is inhibited by the complex R.

Our model has 9 states in total and 37 parameters, including the Acetaldehyde-AlcR input and LuxR. Basal expression is considered for none of the states and linear degradation is considered for all of them.

Band Detector

The band detector is an amplitude band-pass filter that gives a GFP output when acetaldehyde is in a certain concentration range. The filter is a feed-forward system with 2 branches – an amplitude low-pass filter and an amplitude high-pass filter – interconnected by a NOR gate.

The input of the system is acetaldehyde which binds to AlcR. After the complex TetR inhibition by the acetaldehyde-AlcR complex the systems splits into the 2 branches, the slow branch and the fast branch.

The fast branch is the amplitude low-pass filter. This means that it will repress the production of GFP when the acetaldehyde concentration goes above the high threshold.In other words, GFP is produced only at low acetaldehyde concentrations. High acetaldehyde concentration will repress TetR which will not be able to repress LacIm1, GFP production being thus inhibited.

The slow branch is the amplitude high-pass filter which represses GFP when acetaldehyde concentration falls below the low threshold or in other words GFP is produced only at high levels of acetaldehyde.

By combining these 2 filters, GFP is produced when neither LacIm1 or LacI represses it, which is region between the two thresholds. This region is the range of acetaldehyde concentration which can trigger the GFP pulse. The ODEs for the species involved in the band detector are given below.


Bandpasseq.png


We simulated the model for 5000s and for various concentrations of acetaldehyde. In the following figure you can see how the steady state concentration of GFP changes for different input concentrations of acetaldehyde. The band is formed when the acetaldehyde concentration is approximately in the range of 500-1500 microMolars. The peak of the GFP pulse is observed when the acetaldehyde concentration is 1000 microMolars.

AcABandpass.png


Sensitivity Analysis

Sensitivity analysis is a technique that studies the change of the output (or any observable) of a certain function with variation of a certain parameter. It gives as an overview how sensitive the model is with respect to the parameter, i.e. what the impact of the parameter is. The sensitivity is defined as a partial differential equation of the observable with respect to a certain parameter.

Since we consider acetaldehyde as a parameter in our model, we did sensitivity analysis with respect to acetaldehyde. For different acetaldehyde concentrations we monitored the change in the GFP output (dGFP/dAcetaldehyde). It can be seen from the figure below that the sensitivity is highest when GFP rises. For the peak itself (at [AA] = 1000uM), the sensitivity drops down and then rises again once GFP concentration starts decreasing. This tells us that the GFP concentration level is most sensitive to acetaldehyde at those acetaldehyde concentrations when GFP rises and falls.


Sensitivity steps 20.png

Parameter sweeps

For the parameters included in the band detector module, we explored the parameter space around their values which we found in the literature and used for the simuations in order to see how they can affect the band width and height. As we varied each parameter (while keeping the rest constant), we varied also the acetaldehyde input and monitored the GFP output.

The following figures represent how the band changes with variation of protein production rates, repression coefficients and degradation rates.


Protein Synthesis Rates

ATetR.png
AC.png
AL1.png
AL2.png
AG.png

Repression Coefficients

BAA.png
BT.png
BC.png
BL.png

Protein Degradation Rates

GTetR.png
GC.png
GL.png
GG.png

Filter

This module acts like a high pass amplitude filter for acetaldehyde, since it produces RFP only when the acetaldehyde concentration goes above a certain threshold.

At high acetaldehyde concentrations, TetR is repressed, so the repression of CI by TetR can not be established. CI is expressed and it inhibits the production of LuxI, which means that AHL is not produced. Once AHL is not there, it can not bind to LuxR, so LuxR can't repress RFP any more. This results in RFP expression; all the cells turn red. As mentioned, this module of the model acts as a hight pass amplitude filter for acetaldehyde, or low pass amplitude filter for AHL, since AHL is produced only when the acetaldehyde levels are low.

The ODEs for the states involved in the second module of the system are given below:


Quorum.png


The RFP steady state concentration plotted against increasing acetaldehyde concentration is presented in the figure below. RFP appears after acetaldehyde crosses the threshold of 500 microMolars.


Filter.png