Team:ETH Zurich/Achievements/Model Results

From 2011.igem.org

(Difference between revisions)
(Feasibility Analysis)
 
(9 intermediate revisions not shown)
Line 1: Line 1:
-
{{:Team:ETH Zurich/Templates/Header/Achievements|currPage=Modeling_Results}}
+
{{:Team:ETH Zurich/Templates/HeaderNew}}
-
{|class="roundContainer"
+
-
|style="font-size:2em; height: 30px" class="achievements"|Modeling Results
+
-
|
+
-
{|class="linkMap achievementsTitle" align="right"
+
-
|-
+
-
|style="border-left: none;"|[[#Feasibility Analysis|Feasibility Analysis]]
+
-
|[[#Process Design|Process Design]]
+
-
|}
+
-
|-
+
-
|colspan="2"| By modeling and simulating our system we verified that it can actually be implemented in reality. We checked its feasibility, drew some conclusions and decided on a most suitable channel design.
+
-
|}
+
-
{|class="roundContainer"
+
{{:Team:ETH Zurich/Templates/SectionStart}}
-
|
+
= Modeling - Predictions & Results=
-
= Feasibility Analysis =
+
'''By modeling and simulating our system we verified that it can actually be implemented in reality. We checked its feasibility, drew some conclusions and decided on a most suitable channel design.'''
 +
{{:Team:ETH Zurich/Templates/SectionEnd}}
-
'''We verified that our initial idea works and that we can actually get a moving GFP band in the channel responding to different input acetaldehyde concentrations!''' <br>
+
{{:Team:ETH Zurich/Templates/SectionStart}}
-
In order for our SmoColi bacteria to start reporting the presence of acetaldehyde in the air (when the GFP band appears at the beginning of the channel), the system should be supplied with around 44.05 mg/L of acetaldehyde. In order for the band to be able to form at the very end of the channel, the input acetaldehyde concentration should be 2420 mg/L.
+
== Time-Scale Analysis ==
 +
 
 +
=== Does the GFP band move? ===
 +
'''We come to the conclusion that our initial idea may work and that we can actually get a moving GFP band in the channel responding to different input acetaldehyde concentrations!'''
 +
For a 5cm long channel, in order for our SmoColi bacteria to start reporting the presence of acetaldehyde in the air (when the GFP band appears at the beginning of the channel), the system should be supplied with around 44.05 mg/L of acetaldehyde. In order for the band to be able to form at the very end of the channel, the input acetaldehyde concentration should be 2420 mg/L.
{|
{|
|- valign="top"
|- valign="top"
-
|[[File:AcABandpass.png|thumb|380px|center|'''Figure 1''': GFP vs. increasing acetaldehyde input (both in &mu;M). The band appears when the acetaldehyde concentration is in the range of 500-1500 &mu;M]]
+
|[[File:BLA.png|thumb|380px|center|'''Figure 1''': GFP (&mu;M) vs. increasing acetaldehyde input (mg/L). The band appears when the acetaldehyde concentration is in the range of approximately 20-70 mg/L]]
|{{:Team:ETH Zurich/Templates/Flash|name=flash_gfp_ss_sweep|url=/wiki/images/9/94/ETHZ-GFP_SS_Sweep.swf|width=408|widthP2=410|height=240|text='''Video 1: Steady state simulation sweep from 1 to 2500 mg/l acetaldehyde concentration in reservoir:''' 3D GFP concentration in mol/m<sup>3</sup>, 5 slices through the channel. Channel width: 2 mm, Channel length: 5 cm.}}
|{{:Team:ETH Zurich/Templates/Flash|name=flash_gfp_ss_sweep|url=/wiki/images/9/94/ETHZ-GFP_SS_Sweep.swf|width=408|widthP2=410|height=240|text='''Video 1: Steady state simulation sweep from 1 to 2500 mg/l acetaldehyde concentration in reservoir:''' 3D GFP concentration in mol/m<sup>3</sup>, 5 slices through the channel. Channel width: 2 mm, Channel length: 5 cm.}}
|}
|}
-
|}
+
{{:Team:ETH Zurich/Templates/SectionEnd}}
 +
{{:Team:ETH Zurich/Templates/SectionStart}}
-
{|class="roundContainer"
+
== Process Design ==
-
|
+
-
 
+
-
= Process Design =
+
After simulating our system in COMSOL, we came to the following conclusions that helped us designing the channel experimentally:
After simulating our system in COMSOL, we came to the following conclusions that helped us designing the channel experimentally:
* ''E. coli'' can generate a gradient by degrading a substance replenished by diffusion in an agarose-filled channel.
* ''E. coli'' can generate a gradient by degrading a substance replenished by diffusion in an agarose-filled channel.
Line 39: Line 31:
* It can do so within reasonable channel lengths (several centimeters.
* It can do so within reasonable channel lengths (several centimeters.
* Channel diameter is irrelevant for our system.
* Channel diameter is irrelevant for our system.
-
* As mentioned, we need 44.05 mg/L of input acetaldehyde concentration for the band to appear, 2420 mg/L for it to come to the end of the channel.  
+
* As mentioned, for a 5cm long channel, we need 44.05 mg/L of input acetaldehyde concentration for the band to appear, 2420 mg/L for it to come to the end of the channel.  
-
|}
+
{{:Team:ETH Zurich/Templates/SectionEnd}}
 +
{{:Team:ETH Zurich/Templates/HeaderNewEnd}}

Latest revision as of 20:04, 27 October 2011

Can you feel the smoke tonight?
 

Contents

Modeling - Predictions & Results

By modeling and simulating our system we verified that it can actually be implemented in reality. We checked its feasibility, drew some conclusions and decided on a most suitable channel design.

Time-Scale Analysis

Does the GFP band move?

We come to the conclusion that our initial idea may work and that we can actually get a moving GFP band in the channel responding to different input acetaldehyde concentrations! For a 5cm long channel, in order for our SmoColi bacteria to start reporting the presence of acetaldehyde in the air (when the GFP band appears at the beginning of the channel), the system should be supplied with around 44.05 mg/L of acetaldehyde. In order for the band to be able to form at the very end of the channel, the input acetaldehyde concentration should be 2420 mg/L.

Figure 1: GFP (μM) vs. increasing acetaldehyde input (mg/L). The band appears when the acetaldehyde concentration is in the range of approximately 20-70 mg/L
Play
Video 1: Steady state simulation sweep from 1 to 2500 mg/l acetaldehyde concentration in reservoir: 3D GFP concentration in mol/m3, 5 slices through the channel. Channel width: 2 mm, Channel length: 5 cm.
Press play to start video!


Process Design

After simulating our system in COMSOL, we came to the following conclusions that helped us designing the channel experimentally:

  • E. coli can generate a gradient by degrading a substance replenished by diffusion in an agarose-filled channel.
  • No small microfluidics devise needed, no flow needed. The setup can be done in a small tube with diffusion only.
  • It can do so within a reasonable experimental timeframe (within several hours).
  • It can do so within reasonable channel lengths (several centimeters.
  • Channel diameter is irrelevant for our system.
  • As mentioned, for a 5cm long channel, we need 44.05 mg/L of input acetaldehyde concentration for the band to appear, 2420 mg/L for it to come to the end of the channel.


Back to iGEM Our Sponsors
ETHZ-BASF.png ETH Zurich Logo.png ETHZ-Lonza.png ETHZ-Merck Serono.png
ETHZ-Novartis.png ETHZ-Roche.png ETHZ-Syngenta.png DSM MasterLogo.png