Team:ETH Zurich/Achievements/Data page
From 2011.igem.org
(Difference between revisions)
(→Data page) |
(→Data page) |
||
Line 3: | Line 3: | ||
{{:Team:ETH Zurich/Templates/SectionStart}} | {{:Team:ETH Zurich/Templates/SectionStart}} | ||
= Data page = | = Data page = | ||
- | '''SmoColi cells are engineered to sense toxic substances found in cigarette smoke. They are immobilized in a microfluidic channel, in which a concentration gradient of the toxic substance is established. The sensor is linked to a band-pass filter that leads to input-concentration-dependent GFP expression. Continuous increase of the input concentration and its detection, therefore, establishes a moving fluorescent band in the channel. Finally, if the input concentration exceeds a certain threshold, cells produce RFP and the device turns red. | + | '''SmoColi cells are engineered to sense toxic substances found in cigarette smoke.''' They are immobilized in a microfluidic channel, in which a concentration gradient of the toxic substance is established. The sensor is linked to a band-pass filter that leads to input-concentration-dependent GFP expression. Continuous increase of the input concentration and its detection, therefore, establishes a moving fluorescent band in the channel. Finally, if the input concentration exceeds a certain threshold, cells produce RFP and the device turns red. |
{{:Team:ETH Zurich/Templates/SectionEnd}} | {{:Team:ETH Zurich/Templates/SectionEnd}} | ||
{{:Team:ETH Zurich/Templates/SectionStart}} | {{:Team:ETH Zurich/Templates/SectionStart}} | ||
+ | |||
= How Our System Works = | = How Our System Works = | ||
<center> | <center> |
Revision as of 11:03, 28 October 2011
Data page
SmoColi cells are engineered to sense toxic substances found in cigarette smoke. They are immobilized in a microfluidic channel, in which a concentration gradient of the toxic substance is established. The sensor is linked to a band-pass filter that leads to input-concentration-dependent GFP expression. Continuous increase of the input concentration and its detection, therefore, establishes a moving fluorescent band in the channel. Finally, if the input concentration exceeds a certain threshold, cells produce RFP and the device turns red.
How Our System Works
Data For Our Favorite New Parts
- [http://partsregistry.org/Part:BBa_K625000 MainPage]-LacIM1, BBa_K625000; E. coli codon-modified LacI designed to avoid recombination with the wild type LacI in a system where both variants are present, LacIM1 binds to Plac and inhibits transcription. (Characterization)
- [http://partsregistry.org/Part:BBa_K625005 MainPage]-Psb6A5, BBa_K625005; improved Plasmid [http://partsregistry.org/Part:pSB6A1 pSB6A1] (ETHZ, 2007): transcriptional terminators added. (Characterization)
- [http://partsregistry.org/Part:BBa_K625003 MainPage]-PU promoter BBa_K625003; improved version of [http://partsregistry.org/Part:BBa_I723138 BBa_I723138] (Glasgow 2007) Promoter regulated by the transcriptional activator XylR (shortened version) (Characterization)
Characterized Existing Parts
- [http://partsregistry.org/Part:BBa_K625001 MainPage]- PTet - LacIM1 - Termination, BBa_K625001 (Characterization)
- [http://partsregistry.org/Part:BBa_K625002 MainPage]-PU promoter, BBa_K625002; improved version of [http://partsregistry.org/Part:BBa_I723138 BBa_I723138] (Glasgow 2007); Promoter regulated by the transcriptional activator XylR (long version with stop codon) (Characterization)