Team:UNIPV-Pavia/Measurements

From 2011.igem.org

Revision as of 21:01, 14 September 2011 by Nickpv (Talk | contribs)

UNIPV TEAM 2011

Contents

pTet protocol

  1. Streak long term storage glycerol stocks on a LB agar plate + Cm12.5 (don't forget positive and negative controls). Let them grow over night.
  2. Pick 3 colonies from each clone and inoculate it in 1 ml M9 + Cm12.5 in a falcon tube; let them grow over night.
  3. Dilute cultures 1:500 in 1 ml of M9 + Cm12.5 and let them grow for three hours.
  4. Induce cultures in falcon tube with anhydrotetracycline (aTc) (final concentrations: 0 ng/ml, 1 ng/ml, 2 ng/ml, 3 ng/ml, 4 ng/ml, 5 ng/ml, 8 ng/ml, 10 ng/ml, 50 ng/ml, 100 ng/ml). Grow cultures for three hours.
  5. Aliquot 200 μl of cultures in microplate wells and measure O.D. and fluorescence with Tecan Infinite F200 microplate reader. Set the automatic procedure:
    • temperature: 37°C
    • sampling time: 5 minutes
    • 15 seconds of linear shaking (3 mm amplitude) followed by 5 seconds waiting before measurements
    • fluorescence gain: 50 - 80
    • O.D. filter: 600 nm
    • RFP filters: 535 nm (excitation) / 620 nm (emission)
    • duration time: 10 - 15 hours

pLux protocol

  1. Streak long term storage glycerol stocks on a LB agar plate + Cm12.5 (don't forget positive and negative controls). Let them grow over night.
  2. Pick 3 colonies from each clone and inoculate it in 1 ml M9 + Cm12.5 in a falcon tube; let them grow over night.
  3. Dilute cultures 1:500 in 1 ml of M9 + Cm12.5 and let them grow for three hours.
  4. Induce cultures in falcon tube with 3OC6-HSL (final concentrations: 0 nM, 0.1 nM, 0.5 nM, 1 nM, 2 nM, 5 nM, 10 nM, 100 nM). Grow cultures for three hours.
  5. Aliquot 200 μl of cultures in microplate wells and measure O.D. and fluorescence with Tecan Infinite F200 microplate reader. Set the automatic procedure:
    • temperature: 37°C
    • sampling time: 5 minutes
    • 15 seconds of linear shaking (3 mm amplitude) followed by 5 seconds waiting before measurements
    • fluorescence gain: 50 - 80
    • O.D. filter: 600 nm
    • RFP filters: 535 nm (excitation) / 620 nm (emission)
    • duration time: 10 - 15 hours

Enzyme activity assay

AiiA activity

Retrieved from "http://2011.igem.org/Team:UNIPV-Pavia/Measurements"