Team:Imperial College London/Project Chemotaxis Testing

From 2011.igem.org

(Difference between revisions)
Line 11: Line 11:
<div class="technology">1. Introduction</div>
<div class="technology">1. Introduction</div>
<div class="thelanguage">
<div class="thelanguage">
-
<p>The assembled construct PA2652 (<a href="http://partsregistry.org/Part:BBa_K515102">BBa_K515102</a>) and non-codon optimised mcpS (in pRK415 backone vector), have been inserted and tested for functionality in <i>E. coli</i> DH5α obtained from New England Biolabs. We carried out several tests in an attempt to characterise the rewired chemotaxis towards L(-)malic acid. We separated testing of chemotaxis towards malate into behavioral, qualitative & quantitative analyses. </p>
+
<p>The assembled PA2652 construct (<a href="http://partsregistry.org/Part:BBa_K515102">BBa_K515102</a>) and non-codon optimised mcpS (in pRK415 backone vector), have been inserted and tested for functionality in <i>E. coli</i> DH5α obtained from New England Biolabs. We carried out several tests in an attempt to characterise the rewired chemotaxis towards L(-)malic acid. We separated testing of chemotaxis towards malate into behavioral, qualitative & quantitative analyses. </p>
-
<p> To test bacterial uptake into the roots of the plants, we worked with <i>Arabidopsis thaliana</i> to replicate the experiment by Paungfoo-Lonhienne et al. <i>A. thaliana</i> is a common plant model organism. Its genome has been almost completely sequenced and replicates quickly, producing a large number of seeds. It is easily transformed and many different mutant strains have been constructed to study its different characteristics<sup>[1]</sup>. While <i>Arabidopsis</i> may not represent plant populations naturally occurring in arid areas threatened by desertification, it is a handy model organism we will be using to study the effect of the auxin plant hormone, indole-3-acetic acid (IAA) on roots, observe chemotaxis towards them, and observe them taking up bacteria as nutrients.</p>  
+
<p> To test bacterial uptake into the roots of the plants, we worked with <i>Arabidopsis thaliana</i> to replicate the experiment by Paungfoo-Lonhienne et al. <i>Arabidopsis </i> is a common plant model organism. It’s genome has been almost completely sequenced and replicates quickly, producing a large number of seeds. Many different mutant strains have been constructed to study its different characteristics<sup>[1]</sup>. While <i>Arabidopsis</i> may not represent plant populations naturally occurring in arid areas threatened by desertification, it is a useful model organism which we will be using to study the effect of the auxin plant hormone, indole-3-acetic acid (IAA) on roots, observe chemotaxis towards them, and observe them taking up bacteria as nutrients.</p>  
<p style="text-align:right;font-size:1.3em;"><a href="#" class="collapseLink" onClick="ddaccordion.collapseone('technology', 0); return false">Collapse</a></p>
<p style="text-align:right;font-size:1.3em;"><a href="#" class="collapseLink" onClick="ddaccordion.collapseone('technology', 0); return false">Collapse</a></p>
Line 23: Line 23:
<br>
<br>
-
<p>Bacteria perform two types of movement, smooth swimming and tumbling. In the absence of attractant the result of the two movements lead to random walk with no directionality. In the presence of a concentration gradient of attractant, the probabilities of the two movements change and lead to the directional movement known as random biased walk.</p>
+
<p>Bacteria perform two types of movement, smooth swimming and tumbling. In the absence of attractant the result of the two movements lead to random walk without directionality. In the presence of a concentration gradient of attractant, the probabilities of the two movements change and lead to the directional movement known as random biased walk.</p>
<br>
<br>
<br>
<br>
Line 34: Line 34:
</td>
</td>
<td>
<td>
-
<p><i>Video 1: Mixed population of GFP-expressing control and non-GFP labelled PA2652 expressing </i>E. coli<i>.</i><i> The bacteria have been placed in motility buffer without attractant and therefore there is no difference in behaviour between the two. Two types of bacterial movement can be observed. As no attractant is present, a majority of the bacteria perform tumbling, however there are individual bacteria that perform smooth swimming, a rapid movement. In this video, bacteria decide randomly between tumbling and smooth swimming, this behaviour is known as random walk. When bacteria perform chemotactic behaviour towards a concentration gradient(not pictured), the probability of the bacteria performing smooth swimming increases after a transient decrease due to saturation of chemoreceptors. This video has been taken as a set of frames, with one frame per four seconds. Imaging done by Imperial College London iGEM team 2011.</i></p>
+
<p><i>Video 1: Mixed population of GFP-expressing control and non-GFP labelled PA2652 expressing </i>E. coli<i>.</i><i> The bacteria have been placed in motility buffer without attractant and therefore there no difference in behaviour between the two is observed. Since no attractant is present, a majority of the bacteria perform tumbling, however there are individual bacteria that perform smooth swimming, a rapid movement. In this video, bacteria decide randomly between tumbling and smooth swimming, which is known as random walk. When bacteria perform chemotactic behaviour towards a concentration gradient(not pictured), the probability of the bacteria performing smooth swimming increases after a transient decrease due to saturation of chemoreceptors. This video has been taken as a set of frames, with one frame per four seconds. Imaging done by Imperial iGEM 2011.</i></p>
</td>
</td>
</tr>
</tr>
Line 40: Line 40:
</div>
</div>
-
<p>After initial attempts to image and analyze random biased walk up a concentration gradient, we have changed the strategy for observation of the bacterial response to malate. We decided to look for a difference in probabilities of bacteria being in either of the two movements. During bacterial movement up a concentration gradient of attractant, the probability of the smooth swimming is higher than that of tumbling. However we have changed the assay to observe difference in velocities, when exposing bacteria to saturated attractant concentration. We expected the velocity of the cells that are capable of the attractant recognition to be different to those that can not. This observation has been performed with bacteria in mid-exponential phase (OD<sub>600</sub> 0.4-0.6) induced in motility buffer 2 hours prior to observation. Bacteria containing construct PA2652 (<a href="http://partsregistry.org/Part:BBa_K515102">BBa_K515102</a>) have been exposed to motility buffer (reference), 10 mM serine (positive control) & 10 mM malate (test).<i>Escherichia coli</i> DH5α without any construct have been exposed to 10 mM malate (negative control). Observation was performed using a Zeiss Axiovert 200 Inverted Fluorescent Microscope, with video collection Volocity software. ImageJ plug-in Manual Tracking was used to collect data and Chemotaxis Tool plug-in to analyze the data.</p>
+
<p>During bacterial movement up a concentration gradient of attractant, the probability of the smooth swimming is higher than that of tumbling. Smooth swimming is a fast, uni-directional movement, whereas tumbling is random and although the speed may not be slow, overall velocity is far less than that of smooth swimming. Due to the complicated set up with a concentration gradient, we changed strategy to look for a difference in the probability of bacteria moving at different velocities when exposed to a saturating attractant concentration. We expected the velocity of saturated cells to be different to those which are not exposed to attractant. The bacteria were grown to mid-exponential phase (OD<sub>600</sub> 0.4-0.6) before being induced in motility buffer 2 hours prior to observation. Bacteria containing construct PA2652 (<a href="http://partsregistry.org/Part:BBa_K515102">BBa_K515102</a>) have been exposed to motility buffer (reference), 10 mM serine (positive control) & 10 mM malate (test).<i>E. coli</i> DH5α without any construct have been exposed to 10 mM malate (negative control). Observations were taken with a Zeiss Axiovert 200 Inverted Fluorescent Microscope and video collection Volocity software. ImageJ plug-in Manual Tracking was used to collect data and Chemotaxis Tool plug-in to analyze the data.</p>
<h3>2.2 Qualitative analysis<a href="https://2011.igem.org/Team:Imperial_College_London/Protocols_Chemotaxis"><img src="https://static.igem.org/mediawiki/2011/5/58/ICL_ProtocolIconDark.png" width="140px" align="right"/></h3></a>
<h3>2.2 Qualitative analysis<a href="https://2011.igem.org/Team:Imperial_College_London/Protocols_Chemotaxis"><img src="https://static.igem.org/mediawiki/2011/5/58/ICL_ProtocolIconDark.png" width="140px" align="right"/></h3></a>
<br>
<br>
-
<p>Qualitative assays were done to inform us about the result of rewiring chemotaxis in <i>E. coli</i> with the engineered constructs mcpS or PA2652 (<a href="http://partsregistry.org/Part:BBa_K515102">BBa_K515102</a>). However it does not inform us about the cell count and the extent to which engineered bacteria can chemotax towards the attractant source.</p>
+
<p>Qualitative assays were done to observe the effect of rewiring chemotaxis in <i>E. coli</i> with the engineered constructs PA2652 and mcpS (<a href="http://partsregistry.org/Part:BBa_K515102">BBa_K515102</a>). </p>
-
<p>A number of methods exist that show chemotaxis towards a source <sup>[2]</sup>. Most of them are based on the properties of semi-solid agar, which allows diffusion of molecules and bacterial movement. We have modified an agar plug assay to observe chemotactic response. The bacteria used were in mid-exponential phase (OD<sub>600</sub> 0.4-0.6). Cells suspended in the semi-solid agar were positioned 2 cm away from the attractant source and left overnight to grow. At the end of the assay the plates were imaged using Fujifilm LAS-3000 Imager.</p>
+
<p>A number of methods exist that show chemotaxis towards a source <sup>[2]</sup>. Most of them are based on the properties of semi-solid agar, which allows diffusion of molecules and bacterial movement. We have modified an agar plug assay, which involves plating bacteria at opposite end of attractant on a petri-dish, to observe chemotaxis. The bacteria used were in mid-exponential phase (OD<sub>600</sub> 0.4-0.6). Cells suspended in the semi-solid agar were positioned 2 cm away from the attractant source and left overnight to grow. At the end of the assay the plates were imaged using Fujifilm LAS-3000 Imager.</p>
-
<p>This assay was done to show the functional chemotaxis of <i> E. coli</i> DH5α transformed with our PA2652 construct (<a href="http://partsregistry.org/Part:BBa_K515102">BBa_K515102</a>) compared to the inability of control <i> E. coli</i> DH5α to do the same. Positive control cells were exposed to increasing concentrations of serine, which is recognised by the endogenous chemoreceptors of <i>E. coli</i>. We have also tested cells containing the non-codon optimised mcpS gene. However due to the lack of information about the construct, and the fact that it is non-standard biobrick format, with several illegal restriction sites within the sequence, we did not test this construct with further analyses.</p>
+
<p>This assay was done to show the functional chemotaxis of <i> E. coli</i> DH5α transformed with our PA2652 construct (<a href="http://partsregistry.org/Part:BBa_K515102">BBa_K515102</a>) compared to the inability of control <i> E. coli</i> DH5α to do the same. Positive control cells were exposed to increasing concentrations of serine, which is recognised by the endogenous chemoreceptors of <i>E. coli</i>, to observe what the movement we are looking for in cells with our construct. We have also tested cells containing the non-codon optimised mcpS gene for qualitative analysis. <p>
-
<p>Results expected from this assay should show clear differences in the shape colonies formed, since the bacteria attracted to the source will move and therefore distort the shape of the colony into eliptical, directed shape towards the source, in comparison with the control, which are expected to look circular as bacteria are equally likely to swim into any direction.</p>
+
<p>Results from this assay should show clear differences in the shape of colonies formed. Bacteria attracted to the source move and distort the colony into an elliptical, directed shape towards the source. We expect the control colonies to look circular because bacteria are equally likely to swim into any direction.</p>
<p><i>Table 1: The concentrations of attractant tested</i></p>
<p><i>Table 1: The concentrations of attractant tested</i></p>
Line 77: Line 77:
<div class="imgbox" style="width:920px;" >
<div class="imgbox" style="width:920px;" >
<img class="border" src="https://static.igem.org/mediawiki/igem.org/5/5a/ICL_semisolid_pc_0to0.1M.png" width="900px" />
<img class="border" src="https://static.igem.org/mediawiki/igem.org/5/5a/ICL_semisolid_pc_0to0.1M.png" width="900px" />
-
<p><i>Figure 1: Rising concentrations of serine were tested. a) 0 mM control - circular colony b) 0.01 mM - circular colony e) 0.1 mM - circular colony d) 1 mM - possible eliptical colony c) 10 mM - eliptical colony f) 100 mM - eliptical colony away from the attractant. (Data collected by Imperial College London iGEM team 2011).</i></p>
+
<p><i>Figure 1: Increasing concentrations of serine were tested. a) 0 mM control - circular colony b) 0.01 mM - circular colony c) 0.1 mM – rendered void due to mis-handling with semi-solid agar  d) 1 mM - circular colony e) 10 mM - elliptical colony f) 100 mM - elliptical colony away from the attractant due to saturation. Data collected by Imperial iGEM 2011.</i></p>
</div>
</div>
<div class="imgbox" style="width:920px;">
<div class="imgbox" style="width:920px;">
<img class="border" src="https://static.igem.org/mediawiki/igem.org/1/11/ICL_pc_17_0to25mM.png" width="900px" />
<img class="border" src="https://static.igem.org/mediawiki/igem.org/1/11/ICL_pc_17_0to25mM.png" width="900px" />
-
<p><i>Figure 2: Rising concentrations of serine were tested. a) 0 mM control - circular colony, b)5 mM - eliptical colony c) 10 mM - eliptical colony d) 15 mM - eliptical colony e) 20 mM - eliptical colony f) 25mM - circular colony. (Data collected by Imperial College London iGEM team 2011).</i></p>
+
<p><i>Figure 2: Increasing concentrations of serine were tested. a) 0 mM control - circular colony, b)5 mM - elliptical colony c) 10 mM - elliptical colony d) 15 mM - elliptical colony e) 20 mM - elliptical colony f) 25mM - elliptical colony.</i></p>
</div>
</div>
<p style="text-align:center;"><b>Negative control</b></p>
<p style="text-align:center;"><b>Negative control</b></p>
<div class="imgbox" style="width:920px;">
<div class="imgbox" style="width:920px;">
<img class="border" src="https://static.igem.org/mediawiki/igem.org/1/19/ICL_semisolid_nc_17_0to0.1M.png" width="900px" />
<img class="border" src="https://static.igem.org/mediawiki/igem.org/1/19/ICL_semisolid_nc_17_0to0.1M.png" width="900px" />
-
<p><i>Figure 3: Rising concentrations of malate were tested. a) 0 mM control - circular colony b) 0.01 mM - circular colony c) 0.1 mM - circular colony d) 1 mM - circular colony e) 10 mM - circular colony f) 100 mM - circular colony. (Data collected by Imperial College London iGEM team 2011).</i></p>
+
<p><i>Figure 3: Increasing concentrations of malate were tested. a) 0 mM control - circular colony b) 0.01 mM - circular colony c) 0.1 mM - circular colony d) 1 mM - circular colony e) 10 mM - circular colony f) 100 mM - circular colony. Data collected by Imperial iGEM 2011.</i></p>
</div>
</div>
<div class="imgbox" style="width:920px;">
<div class="imgbox" style="width:920px;">
<img class="border" src="https://static.igem.org/mediawiki/igem.org/5/5b/ICL_semisolid_nc_17_0to25mM.png" width="900px" />
<img class="border" src="https://static.igem.org/mediawiki/igem.org/5/5b/ICL_semisolid_nc_17_0to25mM.png" width="900px" />
-
<p><i>Figure 4: Rising concentrations of malate were tested. a) 0 M control - circular colony b)5 mM - circular colony c) 10 mM - circular colony d) 15 mM - circular colony e) 20 mM - circular colony, f) 25mM - circular colony. (Data collected by Imperial College London iGEM team 2011).</i></p>
+
<p><i>Figure 4: Increasing concentrations of malate were tested. a) 0 M control - circular colony b)5 mM - circular colony c) 10 mM - circular colony d) 15 mM - circular colony e) 20 mM - circular colony, f) 25mM - circular colony. Data collected by Imperial iGEM 2011.</i></p>
</div>
</div>
<p style="text-align:center;"><b>McpS - pRK415</b></p>
<p style="text-align:center;"><b>McpS - pRK415</b></p>
<div class="imgbox" style="width:920px;">
<div class="imgbox" style="width:920px;">
<img class="border" src="https://static.igem.org/mediawiki/igem.org/2/27/ICL_semisolid_mcpS_0to0.1M.png" width="900px" />
<img class="border" src="https://static.igem.org/mediawiki/igem.org/2/27/ICL_semisolid_mcpS_0to0.1M.png" width="900px" />
-
<p><i>Figure 5: Rising concentrations of malate were tested. a) 0 mM control - circular colony b) 0.01 mM - circular colony c) 0.1 mM - circular colony d) 1 mM - circular colony e) 10 mM - circular colony f) 100 mM - circular colony. (Data collected by Imperial College London iGEM team 2011).</i></p>
+
<p><i>Figure 5: Increasing concentrations of malate were tested. a) 0 mM control - circular colony b) 0.01 mM - circular colony c) 0.1 mM - circular colony d) 1 mM - circular colony e) 10 mM - circular colony f) 100 mM - circular colony. Data collected by Imperial iGEM 2011.</i></p>
</div>
</div>
<div class="imgbox" style="width:920px;">
<div class="imgbox" style="width:920px;">
<img class="border" src="https://static.igem.org/mediawiki/igem.org/1/18/ICL_semisolid_mcpS_0to25mM.png" width="900px" />
<img class="border" src="https://static.igem.org/mediawiki/igem.org/1/18/ICL_semisolid_mcpS_0to25mM.png" width="900px" />
-
<p><i>Figure 6: Rising concentrations of serine were tested. a) 0 mM control - circular colony b)5 mM - circular colony c) 10 mM - eliptical colony formed not in the direction expected d) 15 mM - possible eliptical colony e) 20 mM - possible eliptical colony f) 25 mM - circular colony. (Data collected by Imperial College London iGEM team 2011).</i></p>
+
<p><i>Figure 6: Increasing concentrations of malate were tested. a) 0 mM control - circular colony b)5 mM - circular colony c) 10 mM - elliptical colony formed not in the direction expected d) 15 mM - possible elliptical colony e) 20 mM - possible elliptical colony f) 25 mM - circular colony. Data collected by Imperial iGEM 2011.</i></p>
</div>
</div>
<p style="text-align:center;"><b>PA2652 - <a href="http://partsregistry.org/Part:BBa_K515102">BBa_K515102</a></b></p>
<p style="text-align:center;"><b>PA2652 - <a href="http://partsregistry.org/Part:BBa_K515102">BBa_K515102</a></b></p>
<div class="imgbox" style="width:920px;">
<div class="imgbox" style="width:920px;">
<img class="border"  src="https://static.igem.org/mediawiki/igem.org/b/bc/ICL_semisolid_PA2652_0to0.1M.png" width="900px" />
<img class="border"  src="https://static.igem.org/mediawiki/igem.org/b/bc/ICL_semisolid_PA2652_0to0.1M.png" width="900px" />
-
<p><i>Figure 7: Rising concentrations of malate were tested. a) 0 M control - circular colony b) 0.01 mM - possible eliptical colony the shape is hard to analyze c) 0.1 mM - strange shape of colony observed, however this was not a result of mishandling with semi - solid agar d) 1 mM - colony shape is not perfectly circular however not elliptical either e) 10 mM - circular colony f) 100 mM - circular colony. (Data collected by Imperial College London iGEM team 2011).</i></p>
+
<p><i>Figure 7: Increasing concentrations of malate were tested. a) 0 M control - circular colony b) 0.01 mM - possible elliptical colony the shape is hard to analyze c) 0.1 mM - strange shape of colony observed, we cannot explain this phenomenon d) 1 mM - colony shape is not perfectly circular however not elliptical either e) 10 mM - circular colony f) 100 mM - circular colony. Data collected by Imperial iGEM 2011.</i></p>
</div>
</div>
<div class="imgbox" style="width:920px;">
<div class="imgbox" style="width:920px;">
<img class="border" src="https://static.igem.org/mediawiki/2011/1/17/ICL_semisolid_PA2652_0to25mM.png" width="900px" />
<img class="border" src="https://static.igem.org/mediawiki/2011/1/17/ICL_semisolid_PA2652_0to25mM.png" width="900px" />
-
<p><i>Figure 8: Rising consentrations of serine were tested. a) 0 mM control - circular colony b)5 mM - colony shape was rendered void due to mishandling with semi-solid agar c) 10 mM - possible eliptical shape colony d) 15 mM - circular colony e) 20 mM - colony shape was rendered void due to mishandling with semi - solid agar f) 25mM - circular colony. (Data collected by Imperial College London iGEM team 2011).</i></p>
+
<p><i>Figure 8: Icreasing concentrations of serine were tested. a) 0 mM control - circular colony b)5 mM - colony shape was rendered void due to mishandling with semi-solid agar c) 10 mM - possible elliptical shape colony d) 15 mM - circular colony e) 20 mM - colony shape was rendered void due to mishandling with semi - solid agar f) 25mM - circular colony. Data collected by Imperial iGEM 2011.</i></p>
</div>
</div>
-
<p> The data obtained from this assay was not easily analysed. This assay is qualitative and therefore should provide us with positive or negative result. However upon analysis of the data a definitive conclusion could not be drawn.  This is due to a number of factors in the setup of the assay. Attractant is localised, and it diffuses to all directions, however the plate is not infinite and therefore loss of concentration gradient occurs over time. Another factor is the semi-solid agar itself. This medium is relatively difficult to manipulate with and a number of samples were ruined during the handling. Even considering that the set up of this assay lead to vague results a number of points can be drawn. Positive control have shown that <i>E. coli DH5α</i> are capable of chemotaxis. It has also shown that when added attractant is of too high concentration (10<sup>-1</sup> M) bacteria do not swim directly towards the attractant source since the medium around the source is saturated. Instead they perform chemotaxis in a direction, where the attractant concentration gradient is set up, so that it is in the range for sensing by chemoreceptors. This occurs even if it means that the bacteria effectively move away from the attractant source. Negative control have shown that at any tested concentration of L(-)malic acid <i>E. coli DH5α</i> without PA2652 or mcpS construct do not perform chemotaxis towards attractant show. The assay have, however failed to conclude a result for mcpS or PA2652 construct as the colonies observed have a range of shapes at different attractant concentrations, that do not allow us to conclude positive or negative result.</p>
+
<p> Upon analysis of the data, a definitive conclusion could not be drawn.  This is due to a number of factors in the setup of the assay. Attractant is localised, and it diffuses in all directions, however the plate is finite and therefore loss of concentration gradient occurs over time. Another factor is the semi-solid agar itself, a medium which is very difficult to manipulate. Although the results were vague, a number of points can be drawn. Positive controls have shown that <i>E. coli DH5α</i> are capable of chemotaxis. They have also shown that when the added serine concentration is too high (10<sup>-1</sup> M), bacteria do not swim directly towards the attractant source because the surrounding medium is saturated. Instead they perform chemotaxis in a direction towards which the attractant concentration does not saturate the chemoreceptors. This movement still occurs regardless of the fact that the bacteria are moving away from the attractant source. Negative controls have shown that at any tested concentration of L(-)malic acid, <i>E. coli DH5α</i> without PA2652 or mcpS construct do not perform chemotaxis towards attractant. We could not conclude a result for the mcpS or PA2652 construct with this assay since the colonies observed have a range of shapes at different attractant concentrations.</p>
<p><h2>2.3 Quantitative Analysis <a href="https://2011.igem.org/Team:Imperial_College_London/Protocols_Chemotaxis"><img src="https://static.igem.org/mediawiki/2011/5/58/ICL_ProtocolIconDark.png" width="140px" align="right"/> </a></h2></p>
<p><h2>2.3 Quantitative Analysis <a href="https://2011.igem.org/Team:Imperial_College_London/Protocols_Chemotaxis"><img src="https://static.igem.org/mediawiki/2011/5/58/ICL_ProtocolIconDark.png" width="140px" align="right"/> </a></h2></p>
<br>
<br>
-
<p> In comparison to qualitative assays, quantitative assays are more informative as they provide cell count based on different attractant concentrations and therefore allow identification of the optimal attractant concentration for bacterial chemotaxis. Our analyses were based on the high throughput capillary assay [3]. <p>We have modified this assay to obtain cell count through flow cytometer BD FACScan in contrast to commonly used CFU count. The assay itself is based on a number of capillary tubes filled with different concentrations of attractant placed into bacterial suspension for a period of 30 minutes. Even though the assay itself sounds simple, the set up was proven to be very difficult to lead us to obtain any useful data.</p>
+
<p> In comparison to qualitative assays, quantitative assays are more informative as they provide cell count based on different attractant concentrations and therefore allow identification of the optimal attractant concentration. Our analyses were based on the high throughput capillary assay [3]. <p>We have modified this assay to obtain cell count through a flow cytometer BD FACScan in contrast to commonly used CFU count. The assay itself is based on a number of capillary tubes filled with different concentrations of attractant placed into bacterial suspension for a period of 30 minutes. During this period, bacteria are expected to swim up the capillary and the cell count can be measured by flow cytometry. </p>
<p><i>Table 2: The concentrations of tested serine (control) & malate attractant.</i></p>
<p><i>Table 2: The concentrations of tested serine (control) & malate attractant.</i></p>
Line 142: Line 142:
</table>
</table>
-
<p>The capillaries, however did not function in a way due to a number of issues, which we have not managed to fully address in our set up. First is the suspension of the liquid in the capillary, while capillary is not suspended in liquid. We have tried to parafilm the top of the glass capillary tubes but it did not seem to create full vaccuum. For this reason we have minimised our choice to capillaries that can suspend liquid,so we have continued testing with syringes and 10 µL BioRobotix™ tips with ART barrier. Second main problem we have found, was the generation of surface tension, when we tried to remove the capillaries at the end of the assay, this then influenced the result greatly.
+
<p>The capillaries did not function as we wanted due to a number of issues, which we have not managed to fully address in our set up. The first problem was to keep the liquid in the capillary when it was not suspended in liquid. We tried parafilming the top of the glass capillary tubes but it did not create a full vacuum. This minimised our choice of capillaries to those that can suspend liquid, so we continued testing with syringes and 10 µL BioRobotix™ tips with aerosol resistant tips. The second main problem was the generation of surface tension when we tried to remove the capillaries from the liquid. This issue was unable to be rectified but in future setups we will address this problem by using capillaries with optimal diameter.
<table align="center">
<table align="center">
Line 149: Line 149:
<div class="imgbox" style="width:360px; float:none;">
<div class="imgbox" style="width:360px; float:none;">
<img class="border" src="https://static.igem.org/mediawiki/igem.org/5/56/Small_ICL_syringe_capillaries.jpg" width="340px"/>
<img class="border" src="https://static.igem.org/mediawiki/igem.org/5/56/Small_ICL_syringe_capillaries.jpg" width="340px"/>
-
<p><i>Figure 9: Failed set up of high-throughput capillary assay, using syringes loaded with 100 µL of attractant. Possible reason for non-functionality of this assay is surface tension upon removal of the syringes from bacterial suspension.(Picture by Imperial College London iGEM team 2011).</i></p>
+
<p><i>Figure 9: Failed set up of high-throughput capillary assay, using syringes loaded with 100 µL of attractant. Possible reason for non-functionality of this assay is surface tension upon removal of the syringes from bacterial suspension.</i></p>
</div>
</div>
</td>
</td>
Line 156: Line 156:
<div class="imgbox" style="width:360px; float:none;">
<div class="imgbox" style="width:360px; float:none;">
<img class="border" src="https://static.igem.org/mediawiki/igem.org/5/54/Small_ICL_robotix_capillaries.jpg" width="340px"/>
<img class="border" src="https://static.igem.org/mediawiki/igem.org/5/54/Small_ICL_robotix_capillaries.jpg" width="340px"/>
-
<p><i>Figure 10: Failed set up of high-throughput capillary assay, using 10 µL BioRobotix™ tips. Possible reason for non-functionality of this assay was the use of a multichannel pippette. (Picture by Imperial College London iGEM team 2011).</i></p>
+
<p><i>Figure 10: Failed set up of high-throughput capillary assay, using 10 µL BioRobotix™ tips. Possible reason for non-functionality of this assay was the use of multichannel pipette.</i></p>
</div>  
</div>  
</td>
</td>
Line 162: Line 162:
</table>
</table>
-
<p>To get around this we have tried to build a grid for the capillary tubes and perform the experiment on perfectly leveled surface, however removal of the rack was impossible without the result being influenced by surface tension. The surface tension influenced syringe capillaries to greater extent than 10 µL BioRobotix™ tips. The BioRobotix™ tips however seemed to have problem with releasing equal amounts of attractant with bacteria after the assay was finished and some of the tips did not release any of the liquid. One reason for this can be usage of multichannel pippette. These problems have been observed upon analysis of data. Data has been analyzed with Cyflogic<sup>TM</sup> software, CyFlo Ltd, Finland.</p> <br>
+
<p>To improve the assay we built a grid for the capillary tubes and performed the experiment on a perfectly levelled surface. However, removal of the rack was impossible without the solutions being influenced by surface tension. The surface tension influenced syringe capillaries to greater extent than 10 µL BioRobotix™ tips. The BioRobotix™ tips however seemed to have a problem with releasing equal amounts of attractant with bacteria after the assay was finished and some of the tips did not release any of the liquid. One reason for this may be that we used a multichannel pipette. The problems in setup were translated in the data analyzed with Cyflogic<sup>TM</sup> software, CyFlo Ltd, Finland.</p>  
-
 
+
<div class="imgbox" style="width:600px;margin:0 auto;">
<div class="imgbox" style="width:600px;margin:0 auto;">
<img class="border" src="https://static.igem.org/mediawiki/2011/b/b4/ICL_failed_data.png" width="580px"/>
<img class="border" src="https://static.igem.org/mediawiki/2011/b/b4/ICL_failed_data.png" width="580px"/>
-
<p><i>Figure 11: Negative control are cells without construct PA2652 exposed to rising malate concentrations. Positive control are cells containing PA2652 construct exposed to rising serine concentrations. PA2652 cells is the test of the construct, exposed to rising malate concentrations. Blank consists of empty motility buffer exposed to rising attractant concentrations. Due to an inability to find any statistically significant trends in the data, we concluded that the assay´s set up had failed. (Data collected by Imperial College London iGEM team 2011).</i></p>
+
<p><i>Figure 11: Negative controls are cells without construct PA2652 exposed to increasing malate concentrations. Positive controls are cells containing the PA2652 construct exposed to increasing serine concentrations. PA2652 cells contain the construct, exposed to increasing malate concentrations. Blank consists of empty motility buffer exposed to increasing attractant concentrations. Due to an inability to find any statistically significant trends in the data we have concluded that the assay setup is unable to provide a positive or negative result.</i></p>
</div>  
</div>  
-
 
+
<p> Although we have not managed to fully analyse rewired chemotaxis towards malate in our Phyto-Route construct, the troubleshooting in the setup of assays has provided an insight into the specifications needed to design an assay appropriate to analyse the Phyto-Route construct. </p>
-
 
+
-
<p></p>
+
<p style="text-align:right;font-size:1.3em;"><a href="#" class="collapseLink" onClick="ddaccordion.collapseone('technology', 1); return false">Collapse</a></p>
<p style="text-align:right;font-size:1.3em;"><a href="#" class="collapseLink" onClick="ddaccordion.collapseone('technology', 1); return false">Collapse</a></p>
</div>
</div>
Line 178: Line 175:
<div class="imgbox" style="width:370px; float:right;">
<div class="imgbox" style="width:370px; float:right;">
<img class="border" src="https://static.igem.org/mediawiki/2011/b/b7/Awesome_bac_in_roots_16bit.png" width="350px"/>
<img class="border" src="https://static.igem.org/mediawiki/2011/b/b7/Awesome_bac_in_roots_16bit.png" width="350px"/>
-
<p><i>Figure 12. GFP-expressing </i>E. coli<i> cells inside </i>Arabidopsis<i> roots (data and imaging by Imperial College London iGEM team 2011).</i></p>
+
<p><i>Figure 11. GFP-expressing </i>E. coli<i> cells inside </i>Arabidopsis<i> roots (data and imaging by Imperial College iGEM 2011).</i></p>
</div>
</div>
<p>One important part of our project is the uptake of our bacteria into plant roots. The observation that this occurs in both <i>Arabidopsis</i> and tomatoes and that both <i>E. coli</i> and the yeast <i>Saccharomyces cerevisiae</i> can be taken up by roots (albeit under controlled lab settings) is new and was only published last year <sup>[4]</sup>.  
<p>One important part of our project is the uptake of our bacteria into plant roots. The observation that this occurs in both <i>Arabidopsis</i> and tomatoes and that both <i>E. coli</i> and the yeast <i>Saccharomyces cerevisiae</i> can be taken up by roots (albeit under controlled lab settings) is new and was only published last year <sup>[4]</sup>.  
Line 191: Line 188:
<div class="imgbox" style="width:590px;">
<div class="imgbox" style="width:590px;">
<iframe width="560" height="315" src="http://www.youtube.com/embed/1vk3NJhbSOY?rel=0" frameborder="0" allowfullscreen></iframe>
<iframe width="560" height="315" src="http://www.youtube.com/embed/1vk3NJhbSOY?rel=0" frameborder="0" allowfullscreen></iframe>
-
<p><i>Video 2. Stack of wt </i>Arabidopsis<i> root. The root can be imaged at around 488 nm. (Imaging carried out by Dr Martin Spitaler for Imperial College London iGEM team 2011.)</i></p>
+
<p><i>Video 2. Stack of wt Arabidopsis root. The root can be imaged at around 488nm. Imaging carried out by Dr Martin Spitaler for Imperial College iGEM 2011.</i></p>
</div>
</div>
Line 205: Line 202:
<div class="imgbox" style="width:590px;">
<div class="imgbox" style="width:590px;">
<iframe width="560" height="315" src="http://www.youtube.com/embed/HSp1JYj9FL0?rel=0" frameborder="0" allowfullscreen></iframe>
<iframe width="560" height="315" src="http://www.youtube.com/embed/HSp1JYj9FL0?rel=0" frameborder="0" allowfullscreen></iframe>
-
<p><i>Video 3. Bacteria inside of </i>Arabidopsis thaliana<i> roots. These videos were put together using Z-stack images taken on a confocal microscope. These images can be converted into 3D pictures that allow us to verify that the bacteria can indeed be found inside the roots rather than on the surface (data and imaging by Imperial College London iGEM team 2011).</i></p>
+
<p><i>Video 3. Bacteria inside of </i>Arabidopsis thaliana<i> roots. These videos were put together using Z-stack images taken on a confocal microscope. These images can be converted into 3D pictures that allow us to verify that the bacteria can indeed be found inside the roots rather than on the surface (data and imaging by Imperial College iGEM 2011).</i></p>
</div>
</div>

Revision as of 01:25, 22 September 2011




Module 1: Phyto-Route

Chemotaxis is the movement of bacteria based on attraction or repulsion of chemicals. Roots secrete a variety of compounds that E. coli are not attracted to naturally. Accordingly, we engineered a chemoreceptor into our chassis that can sense malate, a common root exudate, so that it can swim towards the root. Additionally, E. coli are actively taken up by plant roots, which will allow targeted IAA delivery into roots by our system.






Testing

Collapse all | Expand all

1. Introduction

The assembled PA2652 construct (BBa_K515102) and non-codon optimised mcpS (in pRK415 backone vector), have been inserted and tested for functionality in E. coli DH5α obtained from New England Biolabs. We carried out several tests in an attempt to characterise the rewired chemotaxis towards L(-)malic acid. We separated testing of chemotaxis towards malate into behavioral, qualitative & quantitative analyses.

To test bacterial uptake into the roots of the plants, we worked with Arabidopsis thaliana to replicate the experiment by Paungfoo-Lonhienne et al. Arabidopsis is a common plant model organism. It’s genome has been almost completely sequenced and replicates quickly, producing a large number of seeds. Many different mutant strains have been constructed to study its different characteristics[1]. While Arabidopsis may not represent plant populations naturally occurring in arid areas threatened by desertification, it is a useful model organism which we will be using to study the effect of the auxin plant hormone, indole-3-acetic acid (IAA) on roots, observe chemotaxis towards them, and observe them taking up bacteria as nutrients.

Collapse

2. Bacterial chemotaxis towards malate

2.1 Behavioral analysis


Bacteria perform two types of movement, smooth swimming and tumbling. In the absence of attractant the result of the two movements lead to random walk without directionality. In the presence of a concentration gradient of attractant, the probabilities of the two movements change and lead to the directional movement known as random biased walk.




Video 1: Mixed population of GFP-expressing control and non-GFP labelled PA2652 expressing E. coli. The bacteria have been placed in motility buffer without attractant and therefore there no difference in behaviour between the two is observed. Since no attractant is present, a majority of the bacteria perform tumbling, however there are individual bacteria that perform smooth swimming, a rapid movement. In this video, bacteria decide randomly between tumbling and smooth swimming, which is known as random walk. When bacteria perform chemotactic behaviour towards a concentration gradient(not pictured), the probability of the bacteria performing smooth swimming increases after a transient decrease due to saturation of chemoreceptors. This video has been taken as a set of frames, with one frame per four seconds. Imaging done by Imperial iGEM 2011.

During bacterial movement up a concentration gradient of attractant, the probability of the smooth swimming is higher than that of tumbling. Smooth swimming is a fast, uni-directional movement, whereas tumbling is random and although the speed may not be slow, overall velocity is far less than that of smooth swimming. Due to the complicated set up with a concentration gradient, we changed strategy to look for a difference in the probability of bacteria moving at different velocities when exposed to a saturating attractant concentration. We expected the velocity of saturated cells to be different to those which are not exposed to attractant. The bacteria were grown to mid-exponential phase (OD600 0.4-0.6) before being induced in motility buffer 2 hours prior to observation. Bacteria containing construct PA2652 (BBa_K515102) have been exposed to motility buffer (reference), 10 mM serine (positive control) & 10 mM malate (test).E. coli DH5α without any construct have been exposed to 10 mM malate (negative control). Observations were taken with a Zeiss Axiovert 200 Inverted Fluorescent Microscope and video collection Volocity software. ImageJ plug-in Manual Tracking was used to collect data and Chemotaxis Tool plug-in to analyze the data.

2.2 Qualitative analysis


Qualitative assays were done to observe the effect of rewiring chemotaxis in E. coli with the engineered constructs PA2652 and mcpS (BBa_K515102).

A number of methods exist that show chemotaxis towards a source [2]. Most of them are based on the properties of semi-solid agar, which allows diffusion of molecules and bacterial movement. We have modified an agar plug assay, which involves plating bacteria at opposite end of attractant on a petri-dish, to observe chemotaxis. The bacteria used were in mid-exponential phase (OD600 0.4-0.6). Cells suspended in the semi-solid agar were positioned 2 cm away from the attractant source and left overnight to grow. At the end of the assay the plates were imaged using Fujifilm LAS-3000 Imager.

This assay was done to show the functional chemotaxis of E. coli DH5α transformed with our PA2652 construct (BBa_K515102) compared to the inability of control E. coli DH5α to do the same. Positive control cells were exposed to increasing concentrations of serine, which is recognised by the endogenous chemoreceptors of E. coli, to observe what the movement we are looking for in cells with our construct. We have also tested cells containing the non-codon optimised mcpS gene for qualitative analysis.

Results from this assay should show clear differences in the shape of colonies formed. Bacteria attracted to the source move and distort the colony into an elliptical, directed shape towards the source. We expect the control colonies to look circular because bacteria are equally likely to swim into any direction.

Table 1: The concentrations of attractant tested

Molar range

0 mM

0.01 mM

0.1 mM

1 mM

10 mM

100 mM

Milimolar range

0 mM

5 mM

10 mM

15 mM

20 mM

25 mM


Positive control

Figure 1: Increasing concentrations of serine were tested. a) 0 mM control - circular colony b) 0.01 mM - circular colony c) 0.1 mM – rendered void due to mis-handling with semi-solid agar d) 1 mM - circular colony e) 10 mM - elliptical colony f) 100 mM - elliptical colony away from the attractant due to saturation. Data collected by Imperial iGEM 2011.

Figure 2: Increasing concentrations of serine were tested. a) 0 mM control - circular colony, b)5 mM - elliptical colony c) 10 mM - elliptical colony d) 15 mM - elliptical colony e) 20 mM - elliptical colony f) 25mM - elliptical colony.

Negative control

Figure 3: Increasing concentrations of malate were tested. a) 0 mM control - circular colony b) 0.01 mM - circular colony c) 0.1 mM - circular colony d) 1 mM - circular colony e) 10 mM - circular colony f) 100 mM - circular colony. Data collected by Imperial iGEM 2011.

Figure 4: Increasing concentrations of malate were tested. a) 0 M control - circular colony b)5 mM - circular colony c) 10 mM - circular colony d) 15 mM - circular colony e) 20 mM - circular colony, f) 25mM - circular colony. Data collected by Imperial iGEM 2011.

McpS - pRK415

Figure 5: Increasing concentrations of malate were tested. a) 0 mM control - circular colony b) 0.01 mM - circular colony c) 0.1 mM - circular colony d) 1 mM - circular colony e) 10 mM - circular colony f) 100 mM - circular colony. Data collected by Imperial iGEM 2011.

Figure 6: Increasing concentrations of malate were tested. a) 0 mM control - circular colony b)5 mM - circular colony c) 10 mM - elliptical colony formed not in the direction expected d) 15 mM - possible elliptical colony e) 20 mM - possible elliptical colony f) 25 mM - circular colony. Data collected by Imperial iGEM 2011.

PA2652 - BBa_K515102

Figure 7: Increasing concentrations of malate were tested. a) 0 M control - circular colony b) 0.01 mM - possible elliptical colony the shape is hard to analyze c) 0.1 mM - strange shape of colony observed, we cannot explain this phenomenon d) 1 mM - colony shape is not perfectly circular however not elliptical either e) 10 mM - circular colony f) 100 mM - circular colony. Data collected by Imperial iGEM 2011.

Figure 8: Icreasing concentrations of serine were tested. a) 0 mM control - circular colony b)5 mM - colony shape was rendered void due to mishandling with semi-solid agar c) 10 mM - possible elliptical shape colony d) 15 mM - circular colony e) 20 mM - colony shape was rendered void due to mishandling with semi - solid agar f) 25mM - circular colony. Data collected by Imperial iGEM 2011.

Upon analysis of the data, a definitive conclusion could not be drawn. This is due to a number of factors in the setup of the assay. Attractant is localised, and it diffuses in all directions, however the plate is finite and therefore loss of concentration gradient occurs over time. Another factor is the semi-solid agar itself, a medium which is very difficult to manipulate. Although the results were vague, a number of points can be drawn. Positive controls have shown that E. coli DH5α are capable of chemotaxis. They have also shown that when the added serine concentration is too high (10-1 M), bacteria do not swim directly towards the attractant source because the surrounding medium is saturated. Instead they perform chemotaxis in a direction towards which the attractant concentration does not saturate the chemoreceptors. This movement still occurs regardless of the fact that the bacteria are moving away from the attractant source. Negative controls have shown that at any tested concentration of L(-)malic acid, E. coli DH5α without PA2652 or mcpS construct do not perform chemotaxis towards attractant. We could not conclude a result for the mcpS or PA2652 construct with this assay since the colonies observed have a range of shapes at different attractant concentrations.

2.3 Quantitative Analysis


In comparison to qualitative assays, quantitative assays are more informative as they provide cell count based on different attractant concentrations and therefore allow identification of the optimal attractant concentration. Our analyses were based on the high throughput capillary assay [3].

We have modified this assay to obtain cell count through a flow cytometer BD FACScan in contrast to commonly used CFU count. The assay itself is based on a number of capillary tubes filled with different concentrations of attractant placed into bacterial suspension for a period of 30 minutes. During this period, bacteria are expected to swim up the capillary and the cell count can be measured by flow cytometry.

Table 2: The concentrations of tested serine (control) & malate attractant.

Molar range

0 mM

0.001 mM

0.01 mM

0.1 mM

1 mM

10 mM

100 mM

Milimolar range

0 mM

5 mM

10 mM

15 mM

20 mM

25 mM

30 mM

The capillaries did not function as we wanted due to a number of issues, which we have not managed to fully address in our set up. The first problem was to keep the liquid in the capillary when it was not suspended in liquid. We tried parafilming the top of the glass capillary tubes but it did not create a full vacuum. This minimised our choice of capillaries to those that can suspend liquid, so we continued testing with syringes and 10 µL BioRobotix™ tips with aerosol resistant tips. The second main problem was the generation of surface tension when we tried to remove the capillaries from the liquid. This issue was unable to be rectified but in future setups we will address this problem by using capillaries with optimal diameter.

Figure 9: Failed set up of high-throughput capillary assay, using syringes loaded with 100 µL of attractant. Possible reason for non-functionality of this assay is surface tension upon removal of the syringes from bacterial suspension.

Figure 10: Failed set up of high-throughput capillary assay, using 10 µL BioRobotix™ tips. Possible reason for non-functionality of this assay was the use of multichannel pipette.

To improve the assay we built a grid for the capillary tubes and performed the experiment on a perfectly levelled surface. However, removal of the rack was impossible without the solutions being influenced by surface tension. The surface tension influenced syringe capillaries to greater extent than 10 µL BioRobotix™ tips. The BioRobotix™ tips however seemed to have a problem with releasing equal amounts of attractant with bacteria after the assay was finished and some of the tips did not release any of the liquid. One reason for this may be that we used a multichannel pipette. The problems in setup were translated in the data analyzed with CyflogicTM software, CyFlo Ltd, Finland.

Figure 11: Negative controls are cells without construct PA2652 exposed to increasing malate concentrations. Positive controls are cells containing the PA2652 construct exposed to increasing serine concentrations. PA2652 cells contain the construct, exposed to increasing malate concentrations. Blank consists of empty motility buffer exposed to increasing attractant concentrations. Due to an inability to find any statistically significant trends in the data we have concluded that the assay setup is unable to provide a positive or negative result.

Although we have not managed to fully analyse rewired chemotaxis towards malate in our Phyto-Route construct, the troubleshooting in the setup of assays has provided an insight into the specifications needed to design an assay appropriate to analyse the Phyto-Route construct.

Collapse

3. Uptake of bacteria into roots

Figure 11. GFP-expressing E. coli cells inside Arabidopsis roots (data and imaging by Imperial College iGEM 2011).

One important part of our project is the uptake of our bacteria into plant roots. The observation that this occurs in both Arabidopsis and tomatoes and that both E. coli and the yeast Saccharomyces cerevisiae can be taken up by roots (albeit under controlled lab settings) is new and was only published last year [4].

As the amount of auxin needed for enhancing plant growth depends on whether our bacteria are producing the compound outside or inside the plants, we attempted to replicate these findings.

In preparation for confocal imaging, we met with Dr Martin Spitaler and Mark Scott who advised us on how to prepare samples and image them. Confocal microscopy is much more precise than conventional light field microscopy as it eliminates background light by focusing the laser through a pinhole (Mark Scott, oral communication). The confocal microscopy we conducted was focused on imaging GFP expressing bacteria inside Arabidopsis roots to show that uptake of the bacteria takes place.

In an imaging trial run we found that natural fluorescence can be measured in roots in a spectrum that does not interfere with measuring the superfolder GFP expressed by our E. coli cells. In addition, the autofluorescence is strong enough to enable us to identify individual cells (Video 2). We did therefore not need to dye the roots before imaging.







Video 2. Stack of wt Arabidopsis root. The root can be imaged at around 488nm. Imaging carried out by Dr Martin Spitaler for Imperial College iGEM 2011.

In order to prepare the GFP-expressing bacteria for plant uptake, they were spun down and media was exchanged prior to incubation at 37°C to reach exponential phase. Bacteria were then spun down and resuspended in wash buffer (5mM MES) to reach OD 30. 8 ml, 4 ml and 2 ml were added to separate flasks, containing 100ml of half-MS media each. 4ml and 6ml of wash buffer were added to the flasks containing 4ml and 2ml bacteria, respectively. 8 ml of wash buffer was added to the negative control. Ten Arabidopsis seedlings were distributed into each of the flasks. Incubation was carried out for 15 hours prior to imaging.

Prior to imaging, roots were washed in PBS to wash off bacteria and facilitate imaging. We imaged the plants incubated with 8ml of bacteria and were able to find bacteria inside one of the roots. A 3D picture was taken of uninfected roots and roots containing bacteria by taking a Z stack image using confocal microscopy (Video 3).

Video 3. Bacteria inside of Arabidopsis thaliana roots. These videos were put together using Z-stack images taken on a confocal microscope. These images can be converted into 3D pictures that allow us to verify that the bacteria can indeed be found inside the roots rather than on the surface (data and imaging by Imperial College iGEM 2011).

We repeated this experiment at a later date with plants that had been allowed to grow for a longer period of time. The bacteria were predominantly found in root hairs and inside of cells on the root surface (Figure 11). These plants were older than the ones previously used for uptake experiments and bacterial uptake was much more predominant.

These results show that we would be able to expose plants to auxin from inside the roots themselves. This is extremely important for assessing the secretion of auxin by our bacteria. Nevertheless, we will need to conduct further uptake experiments in soil and with other plant species to confirm that uptake would be possible in the projet's eventual implementation stage.

Collapse

4. References

[1] National Institute of Health. (no date) Model Organisms for Biomedical Research. [Online]. Available from: http://www.nih.gov/science/models/arabidopsis/index.html [Accessed 21st September 2011].

[2] Jain RK and Pandey J (2010) Chemotactic responses. Timmis VKN, ed. Handbook of hydrocarbon and lipid microbiology. Berlin, Heidelberg: Springer Berlin Heidelberg, pp. 3933-3955. Available at: http://www.springerlink.com/content/x458521h8420l478/ [Cited September 16, 2011].

[3] Bainer R, Park H and Cluzel P (2003) A high-throughput capillary assay for bacterial chemotaxis. Journal of Microbiological Methods 55: 315-319.

[4] Paungfoo-Lonhienne C et al. (2010) Turning the table: plants consume microbes as a source of nutrients.PLoS One 5(7): e11915.

Collapse