Team:EPF-Lausanne/Notebook/July2011

From 2011.igem.org

(Difference between revisions)
(Thursday, 21 July 2011)
(Thursday, 21 July 2011)
Line 327: Line 327:
[[File:EPFL-2011-07-21_Gibson_detector_fragments_PCR.jpg|thumb|right|Gel from our first attempt to replicate Nadine's PCR, to create fragments for the J61002-based reporter plasmid. None of the expected products show up: they should all be between 700 b and 2.4 kb]]
[[File:EPFL-2011-07-21_Gibson_detector_fragments_PCR.jpg|thumb|right|Gel from our first attempt to replicate Nadine's PCR, to create fragments for the J61002-based reporter plasmid. None of the expected products show up: they should all be between 700 b and 2.4 kb]]
-
Douglas and Alessandro repeated Nadine's unsuccessful PCR, to make the fragments for Gibson assembly of the 'reporter plasmid' (pTet-lacI-pLac-RFP/Lysis). The PCR was just as unsuccessful, showing no trace of the expected products, as shown on the figure to the right. We found two similarly labelled tubes containing J61002-pTet-RFP, so we used both for our PCRs. The 'bis' reactions used the plasmid miniprepped by Allesandro, labelled in green writing. The 'non-bis' reactions used the other plasmid, of mysterious origin (miniprepped by Vincent perhaps?).
+
Douglas and Alessandro repeated Nadine's unsuccessful PCR, to make the fragments for Gibson assembly of the 'reporter plasmid' (pTet-lacI-pLac-RFP/Lysis). The PCR was just as unsuccessful, showing no trace of the expected products, as shown on the figure to the right. The fragments being assembled are:
 +
 
 +
* A J61002 '''backbone''' amplified from the J61002-pTet-RFP plasmid
 +
* '''LacI''' amplified from the Repressilator plasmid
 +
* '''pLac-RFP''' from the T4 Lysis plasmid
 +
* OR '''pLac-T4Lysis''' also from the J61002-pTet-RFP plasmid
 +
 
 +
We found two similarly labelled tubes containing J61002-pTet-RFP, so we used both for our PCRs. The 'bis' reactions used the plasmid miniprepped by Allesandro, labelled in green writing. The 'non-bis' reactions used the other plasmid, of mysterious origin (miniprepped by Vincent perhaps?).  
New reagents were prepared to repeat the PCR, using this time the optimal concentrations recommended by Bio-Rad for the iProof polymerase, i.e. primer concentrations of 0.5 uM and DNA template quantities between 1 pg and 10 ng for 50 ul. Specifically, we prepared a set with 1:1000 diluted template (resulting in a mass between 25 and 100 pg) and a set with 1:100 diluted template (resulting in a mass between 0.25 and 1 ng). They have been frozen with no polymerase, to attempt a touchdown PCR tomorrow.
New reagents were prepared to repeat the PCR, using this time the optimal concentrations recommended by Bio-Rad for the iProof polymerase, i.e. primer concentrations of 0.5 uM and DNA template quantities between 1 pg and 10 ng for 50 ul. Specifically, we prepared a set with 1:1000 diluted template (resulting in a mass between 25 and 100 pg) and a set with 1:100 diluted template (resulting in a mass between 0.25 and 1 ng). They have been frozen with no polymerase, to attempt a touchdown PCR tomorrow.
{{:Team:EPF-Lausanne/Templates/Footer}}
{{:Team:EPF-Lausanne/Templates/Footer}}

Revision as of 16:12, 21 July 2011