Team:Cornell/Results
From 2011.igem.org
(Difference between revisions)
Rockyshell92 (Talk | contribs) |
(→Microfluidics Assembly) |
||
Line 20: | Line 20: | ||
=Microfluidics Assembly= | =Microfluidics Assembly= | ||
+ | ==Binding Experiment== | ||
+ | |||
+ | '''Goal'''- to determine if the biotinylated enzymes would attach to the streptavidin coated wall. | ||
+ | |||
+ | '''Experiment''' | ||
+ | ::*Negative Control- chip that is not coated with strepavidin through which we flowed ATTO 590. | ||
+ | ::*Test- streptavidin coated chip through which we flowed ATTO 590. | ||
+ | ::*Flow Rate- 5ul/min | ||
+ | ::*Run Time- 20min | ||
+ | |||
+ | ::After the experiment, air was flown through the chips and pictures were taken. | ||
+ | |||
+ | ==Lysate Experiment== | ||
+ | |||
+ | '''Goal'''- to determine the effect lysate would have on the binding efficiency between the streptavidin coated walls and the biotinylated enzymes. | ||
+ | |||
+ | '''Experiment''' | ||
+ | ::*Positive Control- streptavidin coated chip through which we flowed ATTO 520 | ||
+ | ::*Negative Control- uncoated chip through which we flowed ATTO 520 | ||
+ | ::*Test- streptavidin coated chip through which we flowed a 5:1 ratio of lysate to ATTO fdafdsfdfdsa 520. | ||
+ | ::*Flow Rate = 5ul/min | ||
+ | ::*Total Run Time = 30min | ||
+ | |||
+ | ::Entire setup was covered in aluminum foil and the lights were dimmed. | ||
+ | After the experiment, air was flown through the chips and pictures were taken. | ||
+ | Channels were filled with DI water and stored in the 4 degree fridge wrapped in Al foil. | ||
+ | |||
+ | ==Continuous Flow Experiment== | ||
+ | |||
+ | '''Goal'''-to determine how long the attached enzymes would stay attached under continuous flow. | ||
+ | |||
+ | ::*Negative Control- noncoated chip | ||
+ | ::*Test- Flow DI water through a chip with ATTO 520 attached to the strepavidin coated PDMS for 15min. | ||
+ | ::*Flow Rate = 200ul/min | ||
+ | ::*Total Run Time = 45min, 3 15 min intervals | ||
+ | |||
+ | ::After each interval, the chip was washed with air and a picture was taken in air. | ||
+ | |||
+ | ==GFP biobrick== | ||
+ | |||
+ | '''Goal'''- to determine if our Avi tagged GFP will bind to our streptavidin coated chip. | ||
+ | |||
+ | '''Experiment''' | ||
+ | ::*Negative Control- A coated chip that is flushed with DI Water | ||
+ | ::*Test- A chip coated with streptavidin with filtered GFP lysate flown through | ||
+ | ::*Flow Rate- 5 ul/min | ||
+ | ::*Total Run Time- 20 | ||
+ | |||
+ | ::The GFP containing cells were lysed with Bugbuster and filtered through a PD-10 Desalting Columns to remove excess biotin. Afterwards the chip was stored in DI Water in the fridge in aluminum foil. 4 days later we took the chip out and imaged it again. Then DI Water was flushed through and the chip was reimaged. It was seen that most of the binding occurred at the inlet port and the first channel. By the second channel there was no binding found. | ||
+ | |||
=Light-Induced Lysis= | =Light-Induced Lysis= | ||
</font> | </font> |
Revision as of 03:23, 29 September 2011
Results |
Protocol |
Notebook |
Parts Submitted
Contents |
Enzymatic Pathway
- Through the summer, we successfully constructed the tagged violacein pathway enzymes VioA, VioB, VioE and submitted those parts to the registry. These three enzymes in series are capable of converting L-tryptophan into prodeoxyviolacein, a dark green colored intermediate of the violacein pathway. Each enzyme sequence was constructed to have the Avi-tag sequence included on its C-terminus, followed by the stop codon so that one single fusion protein is expressed. The avitag is capable of biotinylating the enzymes so that they could be bound to surfaces using a simple NeturAvidin ligand system.
- To simplify the construction process, each enzyme sequence was PCR'd off the iGEM Distribution sample with a KpnI site followed by the iGEM prefix, the gene of interest, and ended with an SphI or HindIII site that replaced the location of the stop codon. These PCR products could then be ligated into a modified pZE12-SMCS backbone which contained the Avitag sequence followed by the stop codon, iGEM suffix and ClaI site. This backbone was constructed using the primer insert method outlined in the Project Description.
- With the modified enzymes, we performed experiments to show their expression and utilization of tryptophan using a UV/Vis spectrometer at the peak wavelengths at which tryptophan responds to (590,638, and 562 nm). The OD measurements of solutions containing equivolume of VioA, VioB, 40 mM Hydrogen Peroxide (for oxidation of tryptophan) and VioE lysate with varying concentration of tryptophan. The results are shown below.
- The green points represent readings at 562 nm, blue at 590 nm, and red at 638 nm at 0.008 g/mL concentration of L-Tryptophan and 40 mM H202. As you can see, the absorbance of tryptophan noticably decreases over a time course of 1 hour. This experiment was recreated varying the ratio of enzymes and concentration of initial tryptophan. The results showed a similar decreasing trend.
Microfluidics Assembly
Binding Experiment
Goal- to determine if the biotinylated enzymes would attach to the streptavidin coated wall.
Experiment
- Negative Control- chip that is not coated with strepavidin through which we flowed ATTO 590.
- Test- streptavidin coated chip through which we flowed ATTO 590.
- Flow Rate- 5ul/min
- Run Time- 20min
- After the experiment, air was flown through the chips and pictures were taken.
Lysate Experiment
Goal- to determine the effect lysate would have on the binding efficiency between the streptavidin coated walls and the biotinylated enzymes.
Experiment
- Positive Control- streptavidin coated chip through which we flowed ATTO 520
- Negative Control- uncoated chip through which we flowed ATTO 520
- Test- streptavidin coated chip through which we flowed a 5:1 ratio of lysate to ATTO fdafdsfdfdsa 520.
- Flow Rate = 5ul/min
- Total Run Time = 30min
- Entire setup was covered in aluminum foil and the lights were dimmed.
After the experiment, air was flown through the chips and pictures were taken. Channels were filled with DI water and stored in the 4 degree fridge wrapped in Al foil.
Continuous Flow Experiment
Goal-to determine how long the attached enzymes would stay attached under continuous flow.
- Negative Control- noncoated chip
- Test- Flow DI water through a chip with ATTO 520 attached to the strepavidin coated PDMS for 15min.
- Flow Rate = 200ul/min
- Total Run Time = 45min, 3 15 min intervals
- After each interval, the chip was washed with air and a picture was taken in air.
GFP biobrick
Goal- to determine if our Avi tagged GFP will bind to our streptavidin coated chip.
Experiment
- Negative Control- A coated chip that is flushed with DI Water
- Test- A chip coated with streptavidin with filtered GFP lysate flown through
- Flow Rate- 5 ul/min
- Total Run Time- 20
- The GFP containing cells were lysed with Bugbuster and filtered through a PD-10 Desalting Columns to remove excess biotin. Afterwards the chip was stored in DI Water in the fridge in aluminum foil. 4 days later we took the chip out and imaged it again. Then DI Water was flushed through and the chip was reimaged. It was seen that most of the binding occurred at the inlet port and the first channel. By the second channel there was no binding found.
Light-Induced Lysis