Team:Washington/Magnetosomes/GibsonResults

From 2011.igem.org

(Difference between revisions)
(Comparison between pGA and pSB vectors)
(Comparison between pGA and pSB vectors)
Line 6: Line 6:
==Comparison between pGA and pSB vectors==
==Comparison between pGA and pSB vectors==
To quantitatively illustrate that higher cloning efficiency is achieved with pGA vectors than with standard pSB vectors, we conducted a [https://2011.igem.org/Team:Washington/Protocols/pGA comparative Gibson assembly assay]. For the pGA vector assay, we used a [http://partsregistry.org/wiki/index.php?title=Part:BBa_K173025 pLac-GFP] insert from pGA1C3 with a pGA1A3 backbone. Both of these had already been previously gel extracted, therefore, we proceed straight to the Gibson Reaction. For the pSB vectors, we started with the same pLacGFP insert from a pSB3K3 with a pSB1A3 Backbone. Both the insert and backbone were amplified using PCR (20 ng/uL of DNA), and gel extracted. From this point, we preformed our Gibson Assay.
To quantitatively illustrate that higher cloning efficiency is achieved with pGA vectors than with standard pSB vectors, we conducted a [https://2011.igem.org/Team:Washington/Protocols/pGA comparative Gibson assembly assay]. For the pGA vector assay, we used a [http://partsregistry.org/wiki/index.php?title=Part:BBa_K173025 pLac-GFP] insert from pGA1C3 with a pGA1A3 backbone. Both of these had already been previously gel extracted, therefore, we proceed straight to the Gibson Reaction. For the pSB vectors, we started with the same pLacGFP insert from a pSB3K3 with a pSB1A3 Backbone. Both the insert and backbone were amplified using PCR (20 ng/uL of DNA), and gel extracted. From this point, we preformed our Gibson Assay.
-
 
+
<br/>
 +
[[Image:Washington_GibEff_Equation.png|center|300px]]
 +
<br/>
The Gibson products made using our pGA vectors and the standard pSB vectors were plated separately over 6 plates, and the Gibson assembly efficiency ('''E<sub>G</sub>''') was calculated for each plate by dividing the # of bright colonies ('''C<sub>B</sub>''') by the # of background colonies ('''C<sub>K</sub>''') subtracted from the sum of bright and dim colonies ('''C<sub>B</sub>''' and '''C<sub>C_D</sub>''', respectively).<br/>
The Gibson products made using our pGA vectors and the standard pSB vectors were plated separately over 6 plates, and the Gibson assembly efficiency ('''E<sub>G</sub>''') was calculated for each plate by dividing the # of bright colonies ('''C<sub>B</sub>''') by the # of background colonies ('''C<sub>K</sub>''') subtracted from the sum of bright and dim colonies ('''C<sub>B</sub>''' and '''C<sub>C_D</sub>''', respectively).<br/>
-
[[Image:Washington_GibEff_Equation.png|center|300px]]
 
[[File:Washington_iGEM2011_pGA.png|thumb|left|500px|pGA vector plate]]
[[File:Washington_iGEM2011_pGA.png|thumb|left|500px|pGA vector plate]]
[[File:Washington_iGEM2011_pSB.png|thumb|right|500px|pSB vector plate]]
[[File:Washington_iGEM2011_pSB.png|thumb|right|500px|pSB vector plate]]
<br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/>
<br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/>
-
Once the Gibson efficiences were calculated for each set of plates, the average Gibson efficiency was calculated. The average Gibson efficiency of using our pGA vectors was '''0.991129032'''. This value is significantly higher than that of the pSB vectors (efficiency = 0.116395664). Visually, one can see that there are more fluorescent colonies on the pGA plate vs the pSB plate.  
+
Once the Gibson efficiences were calculated for each set of plates, the average Gibson efficiency was calculated. The average Gibson efficiency of using our pGA vectors was '''0.99'' with a standard error of 0.002. This value is significantly higher than that of the pSB vectors with an assembly efficiency of 0.12 with a standard error of 0.01. Visually, one can see that there is a much higher ratio of fluorescent colonies to nonfluorescent colonies on the pGA plate compared to the pSB plate. One additional thing to note is that the pGA transformation required one-tenth less product from the Gibson assembly reaction to produce roughly the same number of colony forming units, suggesting a higher likelihood of getting proper inserts for more difficult assembly reactions such as those with more than two fragments.
[[File:Washington_iGEM2011_VectorComparison.png|thumb|center|500px|Gibson Assembly Efficiency Comparison]]
[[File:Washington_iGEM2011_VectorComparison.png|thumb|center|500px|Gibson Assembly Efficiency Comparison]]
Based on the comparison presented, we can be certain that our Gibson Assembly vectors (pGA vectors) are a great choice for gene assemblies!
Based on the comparison presented, we can be certain that our Gibson Assembly vectors (pGA vectors) are a great choice for gene assemblies!

Revision as of 19:39, 28 September 2011


Gibson Toolkits: Assembly Efficiency


Comparison between pGA and pSB vectors

To quantitatively illustrate that higher cloning efficiency is achieved with pGA vectors than with standard pSB vectors, we conducted a comparative Gibson assembly assay. For the pGA vector assay, we used a [http://partsregistry.org/wiki/index.php?title=Part:BBa_K173025 pLac-GFP] insert from pGA1C3 with a pGA1A3 backbone. Both of these had already been previously gel extracted, therefore, we proceed straight to the Gibson Reaction. For the pSB vectors, we started with the same pLacGFP insert from a pSB3K3 with a pSB1A3 Backbone. Both the insert and backbone were amplified using PCR (20 ng/uL of DNA), and gel extracted. From this point, we preformed our Gibson Assay.

Washington GibEff Equation.png


The Gibson products made using our pGA vectors and the standard pSB vectors were plated separately over 6 plates, and the Gibson assembly efficiency (EG) was calculated for each plate by dividing the # of bright colonies (CB) by the # of background colonies (CK) subtracted from the sum of bright and dim colonies (CB and CC_D, respectively).

pGA vector plate
pSB vector plate






















Once the Gibson efficiences were calculated for each set of plates, the average Gibson efficiency was calculated. The average Gibson efficiency of using our pGA vectors was '0.99 with a standard error of 0.002. This value is significantly higher than that of the pSB vectors with an assembly efficiency of 0.12 with a standard error of 0.01. Visually, one can see that there is a much higher ratio of fluorescent colonies to nonfluorescent colonies on the pGA plate compared to the pSB plate. One additional thing to note is that the pGA transformation required one-tenth less product from the Gibson assembly reaction to produce roughly the same number of colony forming units, suggesting a higher likelihood of getting proper inserts for more difficult assembly reactions such as those with more than two fragments.

Gibson Assembly Efficiency Comparison

Based on the comparison presented, we can be certain that our Gibson Assembly vectors (pGA vectors) are a great choice for gene assemblies!