Team:Groningen/modeling results

From 2011.igem.org

(Difference between revisions)
Line 30: Line 30:
===Setting up the model===
===Setting up the model===
-
The second code segment shows how the model is constructed. As you can see it is build from smaller modeling components as described [[https://2011.igem.org/Team:Groningen/modeling_simulation_engine|here]]. The first argument a part receives is always the ParameterSetting that was constructed above, from this it the component will draw the parameters that govern its behavior.
+
The second code segment shows how the model is constructed. As you can see it is build from smaller modeling components as described [[https://2011.igem.org/Team:Groningen/modeling_simulation_engine | here]]. The first argument a part receives is always the ParameterSetting that was constructed above, from this it the component will draw the parameters that govern its behavior.
   Dim Arabinose As Compound = New Protein(ParameterSetting, "Arabinose")
   Dim Arabinose As Compound = New Protein(ParameterSetting, "Arabinose")

Revision as of 22:20, 21 September 2011


Results

A simple characterization example

In its most simple use the Cumulus system can be used to characterize promoters. The example below shows how this can be done for the Pbad Promoter (BBa_I0500) with flow cytometry data. The measurements points are generated by comparing a measurement of an unknown part against some measurements from a well characterized one.


Setting up the parameter space

The code below shows how we set the initial parameters for the Pbad Promoter. In it you see parameters getting added to a parameter set. The arguments of the operation are the part's name, followed by the parameter's name and then finally a series of three numbers. Being the estimated parameter value, the minimal, and the maximal value we think it can take. Defining these is the responsibility of the user.

 Dim ParameterSetting As ParameterSetting = New ParameterSetting()
 ParameterSetting.Add("Pbad Promoter", "LeakageActivation", 0.0001, 0, 0.01)
 ParameterSetting.Add("Pbad Promoter", "MaximumActivation", 0.02, 0.01, 0.02)
 ParameterSetting.Add("Pbad Promoter", "KMid", 20000, 10000, 40000)
 ParameterSetting.Add("Pbad Promoter", "Cooperativety", 2, 1, 3)
 ParameterSetting.Add("Arabinose", "Halflife", 2520, 600, 3600)
 ParameterSetting.Add("GFP", "Halflife", 2520, 600, 3600)
 ParameterSetting.Add("GFP Transcript", "Halflife", 240, 180, 300)
 ParameterSetting.Add("GFP Transcript", "RIBS", 0.02, 0, 0.1)
 ParameterSetting.Add("GFP Transcript", "Delay", 300, 120, 600)
 ParameterSetting.Add("Pbad Sequence", "CopyNumber", 10, 9, 11)
 ParameterSetting.Add("Pbad Sequence", "TranscriptionTime", 300, 120, 600)
 ParameterSetting.Add("Extracellular Arabinose", "TransportRate", 0.00001, 0, 1)

Setting up the model

The second code segment shows how the model is constructed. As you can see it is build from smaller modeling components as described [| here]. The first argument a part receives is always the ParameterSetting that was constructed above, from this it the component will draw the parameters that govern its behavior.

 Dim Arabinose As Compound = New Protein(ParameterSetting, "Arabinose")
 Dim GFP As Compound = New Protein(ParameterSetting, "GFP")
 Dim GFPGene As Gene = New Gene(ParameterSetting, "GFPGene", GFP)
 Dim PbadPromoter As AdditiveHillPromoter = New AdditiveHillPromoter(ParameterSetting, "Pbad Promoter", "Arabinose")
 Dim GFPTranscript As Transcript = New RegularTranscript(ParameterSetting, "GFP Transcript", GFPGene)
 Dim PbadSequence As Sequence = New Sequence(ParameterSetting, "Pbad Sequence", PbadPromoter, GFPTranscript)  
 Dim Sequences As List(Of Sequence) = New List(Of Sequence)
 Sequences.Add(PbadSequence)
 Dim Compounds As List(Of Compound) = New List(Of Compound)
 Compounds.Add(Arabinose)
 Compounds.Add(GFP)
 Dim Environmentals As List(Of Environmental) = New List(Of Environmental)
 Environmentals.Add(New ExtracellularConcentration(ParameterSetting, "Arabinose"))
 Dim Cell As Cell = New Cell(Sequences, Compounds, Environmentals)
 Return New Model(Cell)

Running the model

The movie below shows how the algorithm searches for the optimal parameters over 400 epochs. movie

Visulisation of out model

Because we did not manage to finish our complete device we decided to try and model our device in the Cumulus system without any measurement data. One of the main problems in assembling our device in the wetlab seemed to be the defective hybB promoter. For this reason in this model we replaced it with a LacI promoter. In order to operate our system we also assume that we can remove both arabinose and IPTG from the medium in an effcient way. As you can see with these small modifications we get a perfectly working system.

This figure shows a simulation of our full model. As you can see in the bottomleft corner we induce twice with IPTG for ten minutes, once after 5000 seconds and a second time after 15000 seconds, finally reset the system with a long exposure to arabinose in the medium after 25000


Speedup

The Cumulus system allows for large speedups by parallelization through both the cloud and added machines. We tried this with some typical cloud intances and some local machines in the lab, the results are listed below. The benchmarking was done the the Pbad characterization task described above.