Team:Wageningen UR/Project/Devices
From 2011.igem.org
RubenvanHeck (Talk | contribs) (→Custom fluidic device designed by Team Wageningen UR to measure oscillations) |
RubenvanHeck (Talk | contribs) m (→Custom fluidic device designed by Team Wageningen UR to measure oscillations) |
||
Line 27: | Line 27: | ||
The [http://www.nature.com/nature/journal/v463/n7279/abs/nature08753.html article] we based our oscillatory system on, used microfluidic devices to physically constrain the host cells. This was necessary to induce and monitor oscillatory behavior of a population of ''E.coli'' . Such microfluidic devices are very expensive and can only be used once. Therefore we set out to find a cheap alternative for these microfluidic devices. Because a proper alternative was not available we eventually designed our own flow device of which the design is seen in figure 1. For pictures of the device with dimensions click [https://2011.igem.org/Team:Wageningen_UR/Project/DevicesAdditional#Custom_fluidic_device_designed_by_Team_Wageningen_UR_to_measure_oscillations here] or download the Google sketch-up file [http://sourceforge.net/projects/theconstructor/files/ here]. | The [http://www.nature.com/nature/journal/v463/n7279/abs/nature08753.html article] we based our oscillatory system on, used microfluidic devices to physically constrain the host cells. This was necessary to induce and monitor oscillatory behavior of a population of ''E.coli'' . Such microfluidic devices are very expensive and can only be used once. Therefore we set out to find a cheap alternative for these microfluidic devices. Because a proper alternative was not available we eventually designed our own flow device of which the design is seen in figure 1. For pictures of the device with dimensions click [https://2011.igem.org/Team:Wageningen_UR/Project/DevicesAdditional#Custom_fluidic_device_designed_by_Team_Wageningen_UR_to_measure_oscillations here] or download the Google sketch-up file [http://sourceforge.net/projects/theconstructor/files/ here]. | ||
+ | |||
[[File:mainpic.jpg]] | [[File:mainpic.jpg]] | ||
Line 42: | Line 43: | ||
Another bacterial platform is the microdish. The microdish – as depicted in figure 3 – is a thin acrylic layer with pores which is superimposed on a layer of porous aluminum oxide. The wells depicted in figure 3 have a diameter of 180 um and a depth of 40 um. Because the bottom of the wells is porous, nutrients can freely diffuse through the material to any cells contained in the well. These cells will divide until they are physically constrained by the borders of the well. Therefore this is another platform potentially capable of inducing and monitoring oscillatory behavior of a population of ‘‘E.coli’’. | Another bacterial platform is the microdish. The microdish – as depicted in figure 3 – is a thin acrylic layer with pores which is superimposed on a layer of porous aluminum oxide. The wells depicted in figure 3 have a diameter of 180 um and a depth of 40 um. Because the bottom of the wells is porous, nutrients can freely diffuse through the material to any cells contained in the well. These cells will divide until they are physically constrained by the borders of the well. Therefore this is another platform potentially capable of inducing and monitoring oscillatory behavior of a population of ‘‘E.coli’’. | ||
+ | |||
[[File:microdish.jpg]] | [[File:microdish.jpg]] | ||
Line 51: | Line 53: | ||
The induction and observation of oscillatory behavior in a population of ‘‘E.coli’’ on the microsieve requires a cake of cells to be present on the membrane of the microsieve. In the dairy industrythis is achieved by applying the filtrate through an inflow port leading to a chamber, which houses the microsieve. Because an overpressure is produced in the chamber, liquid will be forced through the sieve and the suspended particles – in our case ‘‘E.coli’’ cells – will aggregate on the sieve. To prevent that the pressure in the chamber becomes so high that cells get lysed by being pushed through the filter also an outflow port is included. In the figure below the functional components of the flow device are depicted. | The induction and observation of oscillatory behavior in a population of ‘‘E.coli’’ on the microsieve requires a cake of cells to be present on the membrane of the microsieve. In the dairy industrythis is achieved by applying the filtrate through an inflow port leading to a chamber, which houses the microsieve. Because an overpressure is produced in the chamber, liquid will be forced through the sieve and the suspended particles – in our case ‘‘E.coli’’ cells – will aggregate on the sieve. To prevent that the pressure in the chamber becomes so high that cells get lysed by being pushed through the filter also an outflow port is included. In the figure below the functional components of the flow device are depicted. | ||
+ | |||
+ | |||
[[File:innerdevice.jpg]] | [[File:innerdevice.jpg]] | ||
Revision as of 17:58, 20 September 2011