Building a Synchronized Oscillatory System

Custom fluidic device designed by Team Wageningen UR to measure oscillations



The following pictures depict the dimensions of the flow device and it,s functional components in micro meters. These pictures dont include the outflow port of the bottom chamber, the dimensions of this port are the same as the inflow port of the bottom chamber. For an up to date google sketch-up file of the final design click [http://sourceforge.net/projects/theconstructor/files/ here].


Chamber.jpg

Dimensions flow chamber.


Corner.jpg

Height bottom chamber and dimensions of the nodge which is necessary for having the mico-dish square in the chamber.


Inside 6.jpg

Dimensions of the bottom chamber and micro-sieve socket.


Inside 7.jpg

Dimensions of micro-sieve socket from top. Nodges have the same function and dimensions as the nodge of the micro-dish.


Inside.jpg

Dimensions of outflow channel and port of top chamber.


Inside2.jpg

Radius of ports,in and out flow channel.


Inside3.jpg

Radius of flowthrough channel and port.


Inside4.jpg

Dimensions of flowthrough channel and port.


Outsidedimensions.jpg

Outside dimensions of flow device.