# In an appropriately labeled tube, combine the following: | # In an appropriately labeled tube, combine the following: | ||
- | # | + | #* 20 μL flash mastermix |
- | # | + | #* 2 μL of each primer being used |
- | # | + | #* ~5 ng of DNA. |
- | # | + | #* total reaction volume = The total reaction volume '''40 μL''' |
# Supplement the remaining volume with water. | # Supplement the remaining volume with water. | ||
# Load the sample in the PCR machine and select an appropriate program based on the primer design. | # Load the sample in the PCR machine and select an appropriate program based on the primer design. | ||
+ | #* Our primers were designed to have an annealing temperature of ~ 65oC. | ||
+ | #**"iGem Flash" = 35-40 cycles: | ||
+ | ##98oC - 10s | ||
+ | ##98oC - 5s | ||
+ | ##63oC - 5s | ||
+ | ##72oC - 1min | ||
+ | ##72oC - 3min | ||
+ | ##4oC - infinite | ||
# Once the PCR is finished, run 4 μL of each sample on a diagnostic gel to visualize approximate band lengths. | # Once the PCR is finished, run 4 μL of each sample on a diagnostic gel to visualize approximate band lengths. | ||
# Incubate the remaining 36 μL of each sample with 1 μL DPN 1 (enzyme) @ 37oC for 1 hour. | # Incubate the remaining 36 μL of each sample with 1 μL DPN 1 (enzyme) @ 37oC for 1 hour. | ||
# Purify each sample using a similar approach to the Gibson DNA purification protocol. | # Purify each sample using a similar approach to the Gibson DNA purification protocol. |
Latest revision as of 22:04, 15 September 2011
High-Yield PCR (Full-Gene Assembly)
- In an appropriately labeled tube, combine the following:
- 20 μL flash mastermix
- 2 μL of each primer being used
- ~5 ng of DNA.
- total reaction volume = The total reaction volume 40 μL
- Supplement the remaining volume with water.
- Load the sample in the PCR machine and select an appropriate program based on the primer design.
- Our primers were designed to have an annealing temperature of ~ 65oC.
- "iGem Flash" = 35-40 cycles:
- 98oC - 10s
- 98oC - 5s
- 63oC - 5s
- 72oC - 1min
- 72oC - 3min
- 4oC - infinite
- Our primers were designed to have an annealing temperature of ~ 65oC.
- Once the PCR is finished, run 4 μL of each sample on a diagnostic gel to visualize approximate band lengths.
- Incubate the remaining 36 μL of each sample with 1 μL DPN 1 (enzyme) @ 37oC for 1 hour.
- Purify each sample using a similar approach to the Gibson DNA purification protocol.