User talk:Yazbo91
From 2011.igem.org
(Difference between revisions)
(10 intermediate revisions not shown) | |||
Line 1: | Line 1: | ||
+ | {{:Team:Edinburgh/tech/Navbox}} | ||
+ | <html><script type="text/javascript" >$(document).ready(function() { | ||
+ | getMenus('team', 'team_foo'); | ||
+ | }); </script></html> | ||
+ | <div class="main_body"> | ||
+ | |||
+ | <p class="h1">Yassen's talk page</p> | ||
+ | |||
Oh hai. | Oh hai. | ||
Line 9: | Line 17: | ||
[[User:Allancrossman|Allancrossman]] 16:38, 9 September 2011 (CDT) | [[User:Allancrossman|Allancrossman]] 16:38, 9 September 2011 (CDT) | ||
+ | |||
+ | ==Tables== | ||
+ | |||
+ | {| class="wikitable centredtext" | ||
+ | |- | ||
+ | !Equipment | ||
+ | !Size (m<sup>3</sup>) | ||
+ | !Cost constant (£) | ||
+ | !Index | ||
+ | !Purchase cost (£) | ||
+ | !Number required | ||
+ | !Total cost (£) | ||
+ | |- | ||
+ | |Boiler | ||
+ | |8 | ||
+ | |70 | ||
+ | |0.8 | ||
+ | |13,218.33 | ||
+ | |4 | ||
+ | |52,873.31 | ||
+ | |- | ||
+ | |Reactor 1 | ||
+ | |4 | ||
+ | |18,5000 | ||
+ | |0.45 | ||
+ | |47,158.74 | ||
+ | |1 | ||
+ | |47,158.74 | ||
+ | |- | ||
+ | |Reactor 2 | ||
+ | |4 | ||
+ | |18,500 | ||
+ | |0.45 | ||
+ | |34,522.22 | ||
+ | |1 | ||
+ | |34,522.22 | ||
+ | |- | ||
+ | |Reactor 3 | ||
+ | |4 | ||
+ | |18,500 | ||
+ | |0.45 | ||
+ | |34,522.22 | ||
+ | |1 | ||
+ | |34,522.22 | ||
+ | |- | ||
+ | |Reactor 4 | ||
+ | |4 | ||
+ | |18,500 | ||
+ | |0.45 | ||
+ | |34,522.22 | ||
+ | |1 | ||
+ | |34,522.22 | ||
+ | |- | ||
+ | |Reactor 5 | ||
+ | |4 | ||
+ | |18,500 | ||
+ | |0.45 | ||
+ | |34,522.22 | ||
+ | |1 | ||
+ | |34,522.22 | ||
+ | |- | ||
+ | |Reactor 6 | ||
+ | |4 | ||
+ | |18,500 | ||
+ | |0.45 | ||
+ | |34,522.22 | ||
+ | |1 | ||
+ | |34,522.22 | ||
+ | |- | ||
+ | |Tank 100-102 | ||
+ | |3.3 | ||
+ | |1,400 | ||
+ | |0.55 | ||
+ | |2,699.67 | ||
+ | |3 | ||
+ | |8099.01 | ||
+ | |- | ||
+ | |Tank 103 | ||
+ | |93.2 | ||
+ | |1,400 | ||
+ | |0.55 | ||
+ | |16,955.35 | ||
+ | |1 | ||
+ | |16,955.35 | ||
+ | |- | ||
+ | |Tank 104 | ||
+ | |40 | ||
+ | |1,400 | ||
+ | |0.55 | ||
+ | |10,647.83 | ||
+ | |1 | ||
+ | |10,647.83 | ||
+ | |- | ||
+ | |Tank 105 | ||
+ | |147 | ||
+ | |1,400 | ||
+ | |0.55 | ||
+ | |21,784.75 | ||
+ | |1 | ||
+ | |21,784.75 | ||
+ | |- | ||
+ | |Tank 106 | ||
+ | |17 | ||
+ | |1,400 | ||
+ | |0.55 | ||
+ | |6,650.82 | ||
+ | |1 | ||
+ | |6,650.82 | ||
+ | |} | ||
+ | |||
+ | {| class="wikitable centredtext" | ||
+ | |- | ||
+ | !Factorial number | ||
+ | !Item | ||
+ | !Factor | ||
+ | |- | ||
+ | |f1 | ||
+ | |Equipment erection | ||
+ | |0.45 | ||
+ | |- | ||
+ | |f2 | ||
+ | |Piping | ||
+ | |0.45 | ||
+ | |- | ||
+ | |f3 | ||
+ | |Instrumentation | ||
+ | |0.15 | ||
+ | |- | ||
+ | |f4 | ||
+ | |Electrical | ||
+ | |0.1 | ||
+ | |- | ||
+ | |f5 | ||
+ | |Buildings, process | ||
+ | |0.1 | ||
+ | |- | ||
+ | |f6 | ||
+ | |Ancillary buildings | ||
+ | |0.2 | ||
+ | |- | ||
+ | |colspan="2"| | ||
+ | |'''Total = 1.45''' | ||
+ | |- | ||
+ | |f10 | ||
+ | |Design and Engineering | ||
+ | |0.25 | ||
+ | |- | ||
+ | |f11 | ||
+ | |Contractor’s Fee | ||
+ | |0.05 | ||
+ | |- | ||
+ | |f12 | ||
+ | |Contingency | ||
+ | |0.1 | ||
+ | |- | ||
+ | |colspan="2"| | ||
+ | |'''Total = 0.4''' | ||
+ | |} | ||
+ | |||
+ | {| class="wikitable centredtext" | ||
+ | |- | ||
+ | !Type | ||
+ | !Amount | ||
+ | !Unit price | ||
+ | !Cost | ||
+ | |- | ||
+ | |Steam | ||
+ | |200 kg/h | ||
+ | |£7/t | ||
+ | |£9811.2 | ||
+ | |- | ||
+ | |Cooling water | ||
+ | |3,000 kg/h | ||
+ | |1.5p/t | ||
+ | |£315.36 | ||
+ | |- | ||
+ | |Power | ||
+ | |100 kWh/d | ||
+ | |1.2p/mj | ||
+ | |£43,200 | ||
+ | |} | ||
+ | |||
+ | {| class="wikitable centredtext" | ||
+ | |- | ||
+ | !Equipment number | ||
+ | !Equipment name | ||
+ | !Comment | ||
+ | |- | ||
+ | |Tank 100,101,102 | ||
+ | |Feed storage tanks | ||
+ | |Capacity: 3.3 m<sup>3</sup> | ||
+ | |- | ||
+ | |Tank 103 | ||
+ | |Product storage tank | ||
+ | |Capacity: 93.2 m<sup>3</sup> | ||
+ | |- | ||
+ | |Tank 104 | ||
+ | |Product storage tank | ||
+ | |Capacity: 40 m<sup>3</sup> | ||
+ | |- | ||
+ | |Tank 105 | ||
+ | |Product storage tank | ||
+ | |Capacity: 147 m<sup>3</sup> | ||
+ | |- | ||
+ | |Tank 106 | ||
+ | |Product storage tank | ||
+ | |Capacity: 17 m<sup>3</sup> | ||
+ | |- | ||
+ | |colspan="3"| | ||
+ | |- | ||
+ | |R-1 | ||
+ | |Pre-treatment reactor | ||
+ | |Capacity:8 m<sup>3</sup>, 140 C, 20 bar | ||
+ | |- | ||
+ | |R-2 | ||
+ | |Thermal depolymerisation of hemicellulose | ||
+ | |Capacity: 4 m<sup>3</sup> | ||
+ | |- | ||
+ | |R-3 | ||
+ | |Hydrous pyrolysis of lignin | ||
+ | |Capacity: 4 m<sup>3</sup> | ||
+ | |- | ||
+ | |R-4 | ||
+ | |Degradation of cellulose | ||
+ | |Capacity: 4 m<sup>3</sup> | ||
+ | |- | ||
+ | |R-5 | ||
+ | |Conversion of glucose to sorbitol | ||
+ | |Capacity: 4 m<sup>3</sup> | ||
+ | |- | ||
+ | |R-6 | ||
+ | |Conversion of glucose to fructose syrup | ||
+ | |Capacity 4 m<sup>3</sup> | ||
+ | |- | ||
+ | |P-1, P-2 | ||
+ | |Pumps | ||
+ | | | ||
+ | |- | ||
+ | |D-1 | ||
+ | |Recovery column | ||
+ | |1 bar | ||
+ | |- | ||
+ | |HE-1, 2, 3, 4 | ||
+ | |Heat exchangers | ||
+ | | | ||
+ | |- | ||
+ | |LI-1, 2, 3, 4, 5, 6, 7, 8, 9 | ||
+ | |Level indicators | ||
+ | |PID control | ||
+ | |- | ||
+ | |TI-1, 2, 3, 4, 5, 6 | ||
+ | |Temperature indicators | ||
+ | |PID control | ||
+ | |- | ||
+ | |FI-1 to FI-15 | ||
+ | |Flow indicators | ||
+ | |PID control | ||
+ | |- | ||
+ | |V-1, 2, 3, 6, 7, 8 | ||
+ | |Mixing valve | ||
+ | | | ||
+ | |- | ||
+ | |V-4, 5 | ||
+ | |Angle valve | ||
+ | | | ||
+ | |- | ||
+ | |V-9 to V-42 | ||
+ | |Gate valve | ||
+ | | | ||
+ | |} | ||
+ | |||
+ | |||
+ | End of tables. | ||
+ | |||
+ | ---- | ||
+ | |||
+ | I moved that to [[Team:Edinburgh/Phage_Display]] though it looks terrible on a smallish screen. And too much whitespace on left and right edges... [[User:Allancrossman|Allancrossman]] 12:22, 28 October 2011 (CDT) | ||
+ | |||
+ | Oops I meant [[Team:Edinburgh/Cell_Display]]. [[User:Allancrossman|Allancrossman]] 12:34, 28 October 2011 (CDT) | ||
+ | |||
+ | ---- | ||
+ | |||
+ | Because aside from looking bad on a smallish screen, it would logically fit better there. On the data page it's a bit redundant. Besides, the data page is supposed to [https://igem.org/Sample_Data_Page follow roughly this format]. [[User:Allancrossman|Allancrossman]] 12:55, 28 October 2011 (CDT) | ||
+ | |||
+ | </div> <!-- /main_body--> | ||
+ | <html></div> <!-- /mids --></html> |
Latest revision as of 17:55, 28 October 2011
Yassen's talk page
Oh hai.
Some comments:
- When you define steady state as meaning 99% of the cellulose is used up, it becomes unclear what it means for cellobiose or glucose.
- You say Figure 3 shows cellobiose doesn't reach a steady state. But it goes to zero. If you mean it goes negative, you'll have to replot the graph to show that...
- You say "Analysing steady state is important to find out whether a system accumulates excess mass or energy" - but we know it can't in reality, right, since this violates physics? Do you mean analysing steady state is important as a way of testing if the model is sane?
Allancrossman 16:38, 9 September 2011 (CDT)
Tables
Equipment | Size (m3) | Cost constant (£) | Index | Purchase cost (£) | Number required | Total cost (£) |
---|---|---|---|---|---|---|
Boiler | 8 | 70 | 0.8 | 13,218.33 | 4 | 52,873.31 |
Reactor 1 | 4 | 18,5000 | 0.45 | 47,158.74 | 1 | 47,158.74 |
Reactor 2 | 4 | 18,500 | 0.45 | 34,522.22 | 1 | 34,522.22 |
Reactor 3 | 4 | 18,500 | 0.45 | 34,522.22 | 1 | 34,522.22 |
Reactor 4 | 4 | 18,500 | 0.45 | 34,522.22 | 1 | 34,522.22 |
Reactor 5 | 4 | 18,500 | 0.45 | 34,522.22 | 1 | 34,522.22 |
Reactor 6 | 4 | 18,500 | 0.45 | 34,522.22 | 1 | 34,522.22 |
Tank 100-102 | 3.3 | 1,400 | 0.55 | 2,699.67 | 3 | 8099.01 |
Tank 103 | 93.2 | 1,400 | 0.55 | 16,955.35 | 1 | 16,955.35 |
Tank 104 | 40 | 1,400 | 0.55 | 10,647.83 | 1 | 10,647.83 |
Tank 105 | 147 | 1,400 | 0.55 | 21,784.75 | 1 | 21,784.75 |
Tank 106 | 17 | 1,400 | 0.55 | 6,650.82 | 1 | 6,650.82 |
Factorial number | Item | Factor |
---|---|---|
f1 | Equipment erection | 0.45 |
f2 | Piping | 0.45 |
f3 | Instrumentation | 0.15 |
f4 | Electrical | 0.1 |
f5 | Buildings, process | 0.1 |
f6 | Ancillary buildings | 0.2 |
Total = 1.45 | ||
f10 | Design and Engineering | 0.25 |
f11 | Contractor’s Fee | 0.05 |
f12 | Contingency | 0.1 |
Total = 0.4 |
Type | Amount | Unit price | Cost |
---|---|---|---|
Steam | 200 kg/h | £7/t | £9811.2 |
Cooling water | 3,000 kg/h | 1.5p/t | £315.36 |
Power | 100 kWh/d | 1.2p/mj | £43,200 |
Equipment number | Equipment name | Comment |
---|---|---|
Tank 100,101,102 | Feed storage tanks | Capacity: 3.3 m3 |
Tank 103 | Product storage tank | Capacity: 93.2 m3 |
Tank 104 | Product storage tank | Capacity: 40 m3 |
Tank 105 | Product storage tank | Capacity: 147 m3 |
Tank 106 | Product storage tank | Capacity: 17 m3 |
R-1 | Pre-treatment reactor | Capacity:8 m3, 140 C, 20 bar |
R-2 | Thermal depolymerisation of hemicellulose | Capacity: 4 m3 |
R-3 | Hydrous pyrolysis of lignin | Capacity: 4 m3 |
R-4 | Degradation of cellulose | Capacity: 4 m3 |
R-5 | Conversion of glucose to sorbitol | Capacity: 4 m3 |
R-6 | Conversion of glucose to fructose syrup | Capacity 4 m3 |
P-1, P-2 | Pumps | |
D-1 | Recovery column | 1 bar |
HE-1, 2, 3, 4 | Heat exchangers | |
LI-1, 2, 3, 4, 5, 6, 7, 8, 9 | Level indicators | PID control |
TI-1, 2, 3, 4, 5, 6 | Temperature indicators | PID control |
FI-1 to FI-15 | Flow indicators | PID control |
V-1, 2, 3, 6, 7, 8 | Mixing valve | |
V-4, 5 | Angle valve | |
V-9 to V-42 | Gate valve |
End of tables.
I moved that to Team:Edinburgh/Phage_Display though it looks terrible on a smallish screen. And too much whitespace on left and right edges... Allancrossman 12:22, 28 October 2011 (CDT)
Oops I meant Team:Edinburgh/Cell_Display. Allancrossman 12:34, 28 October 2011 (CDT)
Because aside from looking bad on a smallish screen, it would logically fit better there. On the data page it's a bit redundant. Besides, the data page is supposed to follow roughly this format. Allancrossman 12:55, 28 October 2011 (CDT)