We have designed a ready-to-use low-cost disinfection system, which can be done in your own garage. It allows the culture of Escherichia coli bacteriocin-producing strains, the separation of bacteriocins, the control of the pH and the killing of the targeted bacteria. All-in-one, straight-forward to build, low-cost and efficient hardware device that hosts our Water Colicin Cleaner.<br/><br/>
-
<b>I. Bacteriocin production system</b>
+
<b>Why is this important?</b><br/><br/>
-
<p>In this section there are two streams, one flows in a permanent loop and contains the E. Coli resistant bacteriocin producer with own synthesized bacteriocins. The second one passes through the UF membrane, so it is rich in bacteriocins and other small particles. </p>
+
We had three cultures: <i>E. coli</i> producing bacteriocins, wild-type <i>E. coli</i> (our pathogens) and cyanobacteria <i>Synechocystis</i> sp. PCC6803. <i>E. coli</i> grows on Luria Bertani broth at 37ºC, <i>Synechocystis</i> grows on our fertilized media at 25ºC. Bacteriocins kills enterobacteriae, but we also wanted it to be isolated from <i>Synechocystis</i>. So, cultures could not be mixed, but bacteriocins had to go from <i>E. coli</i> producing bacteriocins to wild-type <i>E. coli</i> and had to be affected by pH variations, caused by <i>Synechocystis</i>. You get the problem, right?<br/><br/>
 +
 
 +
<b>How have we done this?</b><br/><br/>
 +
We have drained the smartness out of our engineers in order to have a Do It Yourself system where all parts of our projects fit and work. This had its conceptual and practical problems, as you can imagine. Following is an animation of how it works, but please feel free to dig into it down below. <BR/><BR/>
 +
 
 +
 
 +
<h2>What are the requirements of the system?</h2>
 +
Every year iGEM comes up with dozens of projects with interesting applications, but few of them end up in a prototype. This year Valencia team has gone one step further building a scale prototype for a real application: disinfecting pathogens from water. The final design of our model has come after many hours struggling with ourselves in order to find the cleverest solution.<br/><br />
 +
The prototype and its corresponding final design fulfill several requisites:<br /><br/>
 +
• Safety – The most important requirement, it has to be safe for the users and the environment<br />
 +
The team has worked much to avoid operating hazards and risk during construction. First, the corresponding safety measures for doing hardware work, like wearing gloves and using protection glasses were followed. Regarding the operation, it was decided to work with a 12 V energy supply, so there is no electroshock risk. Electrical cables have been protected and have been enough distantly kept from the water flasks. All other hazards related with biosafety have been explained in the corresponding biosafety section (poner link)<br/><br/>
 +
• Cost – Economically accessible for the majority of the applications<br/>
 +
The total cost for out model is just 150 € (see list below)!<br/><br/>
 +
• Size – The dimensions of the apparatus need to be coherent with the disinfected volume and it is desirable to be able to transport it easily.<br/>
 +
The size of our prototype is 70 x 55 x 25 cm, it is easily portable in a suitcase and weighs 7 kg.<br/><br/>
 +
• Ease of use – No advance technical expertise to be required<br/>
 +
Once the cultures are prepared, there is no specific knowledge needed, just wait for clean water!<br/><br/>
 +
• Spare parts – The repair or replacement of failed parts should be simple and safe<br/>
 +
Most of the elements of our design can be easily found and quickly substituted.<br/><br/>
 +
• Autonomous – Renewable energy sources like photovoltaic power generation are ideal to obtain a sustainable supply of energy<br/>
 +
With the exception of cell cultures replacement after some time of use, the rest of the equipment can work alone if energy is supplied. With a total estimated energy consumption of 40 W, several renewable energy sources are adequate.<br/><br/>
 +
 
 +
 
 +
<center><IMG SRC="https://static.igem.org/mediawiki/2011/4/40/Valsetup.JPG" ALT="Overall Setup"></center><br/>
 +
 
 +
<h2>1. Bacteriocin production system</h2>
 +
<p>In this section there are two streams. One flows in a permanent loop and contains the E. Coli resistant bacteriocin producer with own synthesized bacteriocins. The second one passes through the UF membrane, so it is rich in bacteriocins and other small particles. </p>
<p>Constituent elements:</p>
<p>Constituent elements:</p>
<ul>
<ul>
-
     <li>Peristaltic pump (PP): </li>
+
     <li><b>Peristaltic pump (PP) </b></li>
-
<p>This kind of pump is perfect to work with biological cultures since there is no direct contact between the cells and the mechanical parts of the PP, so no cell membrane damage and no temperature increase is expected. The fluid is contained within a flexible silicone tube fitted inside a circular pump casing. This tube is compressed by two rollers attached to the rotor, pulling the fluid in one direction.</p>
+
<p>This kind of pump is perfect to work with biological cultures, since there is no direct contact between the cells and the mechanical parts of the P and consequently, no cell membrane damage and no temperature increase is expected. The fluid is contained within a flexible silicone tube fitted inside a circular pump casing. This tube is compressed by two rollers attached to the rotor, pulling the fluid in one direction.</p>
-
<p>Our PP comes from a used hemodialysis machine which motor didn’t work, so we decided to substitute it with a flamboyant Volkswagen Golf windscreen wiper motor. In order to assemble the wiper motor with the pump we used following additional material:</p>
+
<center><IMG SRC="https://static.igem.org/mediawiki/2011/7/79/Valpump.JPG" ALT="Pump setup detail" width="480" height="360"></center><br/>
 +
<p>Our PP comes from a used hemodialysis machine with an out of order motor. We replaced it with a flamboyant Volkswagen Golf windscreen wiper motor. In order to assemble the wiper motor with the pump we used following additional material:</p>
<p>The motor is coupled with threaded rods to a reinforced steel plate, which at the same time supports the PP. Thanks to the threaded rods we can regulate the distance from the motor to the pump and the angle of the shaft. In order to use the original shaft of the pump, we welded it to a nut with the same metric threat to the one of the motor shaft, achieving a cheap functional peristaltic pump.</p>
<p>The motor is coupled with threaded rods to a reinforced steel plate, which at the same time supports the PP. Thanks to the threaded rods we can regulate the distance from the motor to the pump and the angle of the shaft. In order to use the original shaft of the pump, we welded it to a nut with the same metric threat to the one of the motor shaft, achieving a cheap functional peristaltic pump.</p>
-
   <li>Module of Bacteriocins Separation (MoBS):</li>
+
   <li><b>Module of Bacteriocins Separation (MoBS)</b></li>
-
<p>The aim of this device is to separate the bacteriocins from the E. Coli harvest. In the market you can find ultrafiltration modules, which cost around 1000 €. So we tried to obtain a low-cost solution. We had several designs and built different models until we hit the nail on the head and found a fully functional one. </p>
+
<p>The aim of this device is to separate the bacteriocins from the E. Coli harvest. There are marketed ultrafiltration modules of around 1000 € but after several designs and trials, we found a fully functional low-cost solution. </p>
-
<p>Our final MoBS device consists of different brass piping fittings. The main element is a 1’’ pipe tee with two reduced elbows where the central exit of the tee has an amplifier fitting connected to a hexagonal screw top. On the inside top surface the 2 ’’ Ø UF membrane is supported and its outline part its glued to the metal applying a thin layer of neutral silicone, sealing and fixing the membrane at the same time. The two elbows have another fitting to end in a threaded nipple with ¼ ‘’ hose barb whereby the flow which doesn’t pass the membrane comes and returns to the E. Coli bacteriocin production flask through polyurethane tubes.</p>
+
<center><IMG SRC="https://static.igem.org/mediawiki/2011/7/72/Valmobs1.JPG" ALT="Bacteoricin separator" width="480" height="360" ></center><br/>
 +
<p>Our final MoBS device consists of different brass piping fittings. The main element is a 1’’ pipe tee with two reduced elbows where the central exit of the tee has an amplifier fitting connected to a hexagonal screw top. On the inside top surface the 2 ’’ Ø UF membrane is supported and its outline part is glued to the metal with a thin layer of neutral silicone, sealing and fixing the membrane at the same time. Both elbows have another fitting to end in a threaded nipple with ¼ ’’ hose barb whereby the flow which doesn’t pass the membrane comes and returns to the E. Coli bacteriocin production flask through polyurethane tubes.</p>
<p>The UF membrane is a flat NADIR® polysulfone membrane which is chemical and thermal stable and efficiently working for a wide pH range. Its MWCO value is 20 kDa, so bacteoricin peptides are able to pass the membrane in contrast to other big molecules and cells that are blocked by it. The incoming and outcoming flow of the tee are perpendicular to the permeate so that depositions on the membrane surface are prevented.</p>
<p>The UF membrane is a flat NADIR® polysulfone membrane which is chemical and thermal stable and efficiently working for a wide pH range. Its MWCO value is 20 kDa, so bacteoricin peptides are able to pass the membrane in contrast to other big molecules and cells that are blocked by it. The incoming and outcoming flow of the tee are perpendicular to the permeate so that depositions on the membrane surface are prevented.</p>
<p>The pump is switched off when the proper concentration of bacteriocins is reached in the contaminated water. </p>
<p>The pump is switched off when the proper concentration of bacteriocins is reached in the contaminated water. </p>
 +
 +
 +
</ul>
</ul>
-
<b>2.Controller of pH (CopH)</b><br>
+
<h2>2.Controller of pH (CopH)</h2><br>
-
<p>This is the section of the whole system that controls the activity of the bacteriocins. It connects the flask containing pH regulating cyanobacteria with the water vessel. CopH consists of a ½ ‘’ M-F pipe union with and ending fitting for polyurethane tubes. Inside the pipe union a dialysis membrane has been included to permit small molecules and ion exchanges but avoiding the pass of big molecules, peptides and bacteria, allowing proton transient transfer along the tubes that link the two flasks. In this way, the pH value of the system is directly controlled by the photosynthetic bacteria to permit or inhibit the peptides actuation.</p>
+
<p>This is the section of the whole system that controls the activity of the bacteriocins. It connects the flask containing pH regulating cyanobacteria with the water vessel. CopH consists of a ½ ’’ M-F pipe union with and ending fitting for polyurethane tubes. Inside the pipe union a dialysis membrane has been included to permit small molecules and ion exchanges but avoiding the pass of big molecules, peptides and bacteria, allowing proton transient transfer along the tubes that link both flasks. In this way, the pH value of the system is directly controlled by the photosynthetic bacteria to permit or inhibit the peptides actuation.</p>
-
<p>The dialysis membrane is a SnakeSkin™ Pleated Dialysis Tubing with a 3,500 MWCO value. We cut the tubing dialysis to form a ½ ‘’ round and flat membrane and put it inside the pipe union, held by two equal size toric joints. Contrary to the UF membrane, this type is active at both sides of its surface.</p>
+
<center><IMG SRC="https://static.igem.org/mediawiki/2011/8/8c/Valcoph.JPG" ALT="pH transmitter" width="480" height="360"></center><br/>
 +
 
 +
<p>The dialysis membrane is a SnakeSkin™ Pleated Dialysis Tubing with a 3,500 MWCO value. We cut the tubing dialysis to form a ½ ’’ round and flat membrane and put it inside the pipe union, held by two equal size toric joints. Contrary to the UF membrane, this type is active at both sides of its surface.</p>
<p>All tubes with the exception of the one that is compressed by the peristaltic pump are made of polyurethane, while the one inside the PP is softer, made of silicone, so that the rotor is able to squeeze properly this tube. All tubes have a ¼ ’’ Ø. In addition, we have included throttle valves to all tubes that link the different functional parts of the machine (that means after the UF membrane and before the dyalisis one) as safety elements to be able to regulate the flows. Finally, it is critically required to include a throttle valve in the tube returning to the bacteriocin flask after the MoBS to be able to achieve enough P for the UF membrane separation process.</p>
<p>All tubes with the exception of the one that is compressed by the peristaltic pump are made of polyurethane, while the one inside the PP is softer, made of silicone, so that the rotor is able to squeeze properly this tube. All tubes have a ¼ ’’ Ø. In addition, we have included throttle valves to all tubes that link the different functional parts of the machine (that means after the UF membrane and before the dyalisis one) as safety elements to be able to regulate the flows. Finally, it is critically required to include a throttle valve in the tube returning to the bacteriocin flask after the MoBS to be able to achieve enough P for the UF membrane separation process.</p>
-
<b>3.Hardware work</b><br>
+
<h2>3.Hardware work</h2><br>
-
<p>So far the main equipment of the apparatus has been described. Nevertheless, there are several instruments required to allow cultures to grow and to develop.</p>
+
<p>The main equipment of the apparatus has been described above. However, there are several extra instruments required to allow cultures to grow and develop.</p>
<ul>
<ul>
-
<li>Magnetic stirrer</li>
+
<b><li>Magnetic stirrer</b></li>
-
<p>The agitation of the medium is essential for a correct homogenization of the bacteria and the compounds dissolved in it. For creating our stirrer, we took out the ...............</p>
+
<p>The agitation of the medium is essential for a correct homogenization of the bacteria and the compounds dissolved in it.</p>
<p>Our device is built with a computer fan and a neodymium magnet coming from a hard disk bracket. We stuck the neodymium-iron-boron alloy magnet on the axis fan, so when it is switched on, the magnet is permanently in movement, creating a changing magnetic field. The fan is put inside a watertight box for electric cabling. A stir bar is used to create the agitation in the flasks without affecting the biological harvest. Linked to each fan there is a potentiometer with which the desired speed can be reached.</p>
<p>Our device is built with a computer fan and a neodymium magnet coming from a hard disk bracket. We stuck the neodymium-iron-boron alloy magnet on the axis fan, so when it is switched on, the magnet is permanently in movement, creating a changing magnetic field. The fan is put inside a watertight box for electric cabling. A stir bar is used to create the agitation in the flasks without affecting the biological harvest. Linked to each fan there is a potentiometer with which the desired speed can be reached.</p>
-
<li>Illumination </li>
+
<b><li>Illumination </b></li>
<p>The photosynthetic bacteria need light to do photosynthesis and so to change pH. Our illumination system consists of the LED lamp of a flashlight coupled to a switch.</p>
<p>The photosynthetic bacteria need light to do photosynthesis and so to change pH. Our illumination system consists of the LED lamp of a flashlight coupled to a switch.</p>
-
<li>Temperature Control System</li>
+
<b><li>Temperature Control System</b></li>
-
<p><i>E. Coli</i> needs a 37 ºC medium to grow up at the maximum ratio. Our team constructed a thermostat which keeps this temperature constant. </p>
+
<p><i>E. Coli</i> needs a 37 ºC medium to grow up at the maximum ratio. The team built a thermostat which keeps this temperature constant. </p>
 +
<p>In the following the different parts of the thermostat, including  the control circuit are listed: </p>
 +
<center><IMG SRC="https://static.igem.org/mediawiki/2011/5/5c/Valcircuito.png" ALT="Circuit diagram"></center><br/>
 +
<center><IMG SRC="https://static.igem.org/mediawiki/2011/3/34/Circuito0.png" ></center><br/>
 +
 
 +
 
<p>The operational amplifier has two inputs, the non-inverting V+ and the inverting input V-. Moreover, the output is different to zero when the inputs are non equal.</p>
<p>The operational amplifier has two inputs, the non-inverting V+ and the inverting input V-. Moreover, the output is different to zero when the inputs are non equal.</p>
-
<p>In this way we can check the resistance of the thermal sensor, a thermistor, at 37 ºC and set the variable resistance to this value. Hence when the temperature reaches our taget temperature, we have the same inputs at both entries and therefore the output from the amplifier is zero, opening the relay and so switching off the ceramic resistance that is heating up the biological harvest. The whole ceramic device is covered by a copper casing and sealed with silicone so it is safe to put it directly in water. </p>
+
<p>In this way we can check the resistance of the thermal sensor, a thermistor, at 37 ºC and set the variable resistance to this value. Hence when the temperature reaches our target temperature, we have the same inputs at both entries and therefore the output from the amplifier is zero, opening the relay and so switching off the ceramic resistance that is heating up the biological harvest. The whole ceramic device is covered by a copper casing and sealed with silicone so it is safe to put it directly in water. </p>
-
<br><br><br><br><br><br><br><br>
+
<p>After the initial heating up phase, the resistance will be switched on just when the temperature of the solution given by the thermistor is below the target temperature. In this case, the ceramic resistance is switched on by the relay again and it restarts heating up the medium.</p>
<p>After the initial heating up phase, the resistance will be switched on just when the temperature of the solution given by the thermistor is below the target temperature. In this case, the ceramic resistance is switched on by the relay again and it restarts heating up the medium.</p>
 +
<center><IMG SRC="https://static.igem.org/mediawiki/2011/thumb/1/12/Valtcs.JPG/450px-Valtcs.JPG" width="300" height="400" ALT="Heating resistance"></center><br/>
-
<li>Energy supply</li>
+
<b><li>Energy supply</b></li>
<p>Several trials were tested using solar energy provided by our photovoltaic module to show that renewable energy sources are a future option for many synthetic biology applications. In other experiments, we have utilized a PC power supply for the different instruments of the disinfection machine. Depending of the device we have use one of the three available voltages (12, 5 and 3,3 V):</p>
<p>Several trials were tested using solar energy provided by our photovoltaic module to show that renewable energy sources are a future option for many synthetic biology applications. In other experiments, we have utilized a PC power supply for the different instruments of the disinfection machine. Depending of the device we have use one of the three available voltages (12, 5 and 3,3 V):</p>
-
• 12 V: Peristaltic pump, Temperature Control System
+
• 12 V: Peristaltic pump, Temperature Control System <br></br>
-
• 5 V: Lamp, Magnetic stirrer
+
5 V: Lamp, Magnetic stirrer
<p>Much work has been done to avoid electrical related risks, like film covering of cable welded unions. All cables have been together put inside a water tightbox. Finally three plug terminals have been adapted to the energy supply and to the tightbox to facilitate the connections and making possible to transport the supply energy separately.</p>
<p>Much work has been done to avoid electrical related risks, like film covering of cable welded unions. All cables have been together put inside a water tightbox. Finally three plug terminals have been adapted to the energy supply and to the tightbox to facilitate the connections and making possible to transport the supply energy separately.</p>
<ul>
<ul>
-
<b>Total prototype cost </b><br>
+
<h2>Total prototype cost </h2>
-
<p>One of the goals of the project is to create a working prototype that can be designed and built with low resources. All the components can be easily found or bought in different stores with the exception of the two different used membranes that can be purchased online.</p>
+
<p>One of the goals of the project is to create a working prototype that can be designed and built with low resources.   We achieved this goal as our model just costs 150 €!</br></br>
 +
Moreover, all the components can be easily found or bought in different stores with the exception of the two different used membranes that can be purchased online. </p>
<p>Many of the elements below listed were received as donation, but though an estimated cost has been given as reference expenditure.</p>
<p>Many of the elements below listed were received as donation, but though an estimated cost has been given as reference expenditure.</p>
-
Tabla
+
<center><IMG SRC="https://static.igem.org/mediawiki/2011/e/ed/Valtabla.png" width="480" height="360"></center><br/>
 +
<p>The elements that have zero cost were taken from scrap</p>
   
   
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
<p>Antimicrobial peptides (AMPs) are a diverse group of gene-encoded natural antibiotics found in all living organisms. In multicellular organisms, such as mammalians, defensins and cathelicidins  are a principal component of innate immunity. In unicellular organisms, bacteriocins function to suppress competitor species. AMPs kill bacteria by disruption of membrane integrity and are less likely to induce resistance than common antibiotics, so they have attracted attention in different fields such as medicine and food safety.</p>
 
-
 
-
<center><a href="http://en.wikipedia.org/wiki/Antimicrobial_peptides"><img src="http://upload.wikimedia.org/wikipedia/commons/e/ef/Various_AMPs.png" alt="Diversity of AMPs" title="Diversity of AMPs" width="422" height="327"></a>
 
-
<a href="http://en.wikipedia.org/wiki/Antimicrobial_peptides"><img src="http://upload.wikimedia.org/wikipedia/commons/c/c0/Modes_of_action.png" alt="AMPs' Mode of action" title="AMPs' Mode of action" width="399" height="382"></a></center>
 
-
 
-
<h2> Bacteriocins </h2>
 
-
 
-
<p>Bacteriocins are lethal to bacteria other than the producing strain. As a group, bacteriocins are heterogeneous and are classified according to their molecular weight. The activity spectrum of bacteriocins can be narrow and confined to inhibition of closely related species, or it can be relatively broad and include many different bacterial species. Bacteriocins are often considered more natural than common antibiotics because they are thought to have been present in many of the foods eaten since ancient times. This is one of the reasons why we have chosen bacteriocins over other antimicrobial peptides.</p> <br><br>
 
-
 
-
<b> Microcins</b> <br>
 
-
 
-
<p>Microcins are a peculiar class of gene-encoded low-molecular-mass antibacterial peptides secreted by enterobacteria. They contribute to the regulation of microbial competition within the intestinal microbiota. The genetic systems involved in microcin biosynthesis share a conserved organization. Similar to bacteriocins, microcins exert potent antibacterial activity directed against phylogenetically-related bacterial strains, with minimal inhibitory concentrations in the nanomolar range. </p>
 
-
 
-
<p>Usually, microcins exhibit "Trojan horse" mechanisms of antibacterial activity: some microcin structures are a mime of essential elements, permitting recognition by outer membrane receptors used for vital functions in bacteria and further translocation into the periplasmic space, other microcins are secreted as harmless molecules and further processed in susceptible bacteria to form the toxic entity. When inside target bacteria, microcins bind essential enzymes or interact with the inner membrane to form a bacterial killing structure.</p> <br><br>
 
-
 
-
 
-
 
-
<b> Microcin C51</b><br>
 
-
<div class="floatright"><span><a href="/Image:Valenciateam_MccC51.gif" class="image" title="MccC51.gif"><img alt="" src="https://static.igem.org/mediawiki/2011/c/c8/Valeciateam_MccC51.gif" width="400"  border="0" /></a></span></div>
 
-
Microcin C51 is a nucleopeptide of 1.18 kDa molecular mass and the first described nucleopeptide antibiotic. It contains a heptapeptide with the N-terminal formylmethionine and C-terminal asparagine bound to AMP via an aliphatic chain. Microcine C51 is characterized by a broad spectrum of action. Expression in Escherichia coli is activated upon decelerated growth of cells during their transition to the stationary growth phase. This synthesis is controlled by four genes organized in an operon.<br>
 
-
 
-
Our microcin strain has come from <a href="http://www.waksman.rutgers.edu/severinov/home" TARGET="_blank" title="Severinov Laboratory">Severinov Laboratory</a> at Rutgers State University (Severinov et al. Mol Microbiol. 2007)<br><br>
 
-
 
-
 
-
<b> Colicin G and Colicin H </b><br><br>
 
-
 
-
<p>Colicins are proteins produced by some strains of Escherichia coli that are lethal for related strains of E. coli.
 
-
Colicins of strain CA46 (colicin G producer) and of strain CA58 (colicin H producer) should be the same, and indeed, the sensitivity patterns were nearly identical.</p>
 
-
<p>Only the triple mutant receptors fepA cir fiu was completely resistant to the colicins from these strains.
 
-
(i) the production of colicin by colicinogenic E. coli cells is <b>induced by SOS agents</b>, as is seen with lysogenic phages, and is lethal for producing cells.
 
-
(ii) the produced colicin is released into the medium late after synthesis (later shown not to be the case for all colicins).
 
-
(iii) colicin kills sensitive cells according to single-hit kinetics.
 
-
(iv) colicin is not active against the producing bacteria if there is presence of a specific antagonist protein called the <b>immunity protein</b>.</p>
 
-
 
-
<p>All colicins are organized into three domains, each corresponding to one step of colicin action:</p>
 
-
<ul>
 
-
<li>The <b>N-terminal domain</b> is involved in translocation through the membrane.</li>
 
-
<li>The <b>central domain</b> is involved in binding to the receptor.</li>
 
-
<li>The <b>C-terminal domain</b> contains the active part.</li>
 
-
</ul>
 
-
<br>
 
-
<p>The sequence of the <b>colicin G</b> and <b>colicin H</b> determinants have been deposited under the accession numbers AJ515251 and AJ515252, respectively, in the EMBL/GenBank database. </p>
 
-
<ul>
 
-
  <li><a href="http://www.ncbi.nlm.nih.gov/nuccore/AJ515251" TARGET="_blank" title="UPV">Escherichia coli microcin operon, strain CA46 (CA46 ColG)</a></li>
 
-
  <li><a href="http://www.ncbi.nlm.nih.gov/nuccore/AJ515252 " TARGET="_blank" title="UPV">Escherichia coli microcin operon, strain CA58 (CA58 ColH)</a></li>
 
-
</ul>
 
-
<br>
 
-
<center><img src="https://static.igem.org/mediawiki/2011/9/92/Comparison_of_microcin_gene_clusters.PNG"></center>
 
-
 
-
<br>
 
-
<b>Bibliography</b><br>
 
-
 
-
<p><i>Cascales E et al. Colicin Biology. Microbiol Mol Biol Rev. 2007 March; 71(1): 158–229.</i></p>
 
-
 
-
<p><i>Joerger RD. Alternatives to Antibiotics: Bacteriocins, Antimicrobial Peptides and Bacteriophages. 2003 Poultry Science 82:640–647</i></p>
 
-
 
-
<p><i>Patzer SI et al. The colicin G, H and X determinants encode microcins M and H47, which might utilize the catecholate siderophore receptors FepA, Cir, Fiu and IroN. Microbiology (2003), 149, 2557–2570</i></p>
 
-
 
-
<p><i>Severinov K, Semenova E, Kazakov A, Kazakov T, Gelfand MS. Low-molecular-weight post-translationally modified microcins. Mol Microbiol. 2007 Sep;65(6):1380-94</i></p>
 
-
 
-
 
-
 
 
</div><!-- fin clase col_center_top-->
</div><!-- fin clase col_center_top-->

Latest revision as of 21:19, 21 September 2011



Hardware
We have designed a ready-to-use low-cost disinfection system, which can be done in your own garage. It allows the culture of Escherichia coli bacteriocin-producing strains, the separation of bacteriocins, the control of the pH and the killing of the targeted bacteria. All-in-one, straight-forward to build, low-cost and efficient hardware device that hosts our Water Colicin Cleaner.

Why is this important?

We had three cultures: E. coli producing bacteriocins, wild-type E. coli (our pathogens) and cyanobacteria Synechocystis sp. PCC6803. E. coli grows on Luria Bertani broth at 37ºC, Synechocystis grows on our fertilized media at 25ºC. Bacteriocins kills enterobacteriae, but we also wanted it to be isolated from Synechocystis. So, cultures could not be mixed, but bacteriocins had to go from E. coli producing bacteriocins to wild-type E. coli and had to be affected by pH variations, caused by Synechocystis. You get the problem, right?

How have we done this?

We have drained the smartness out of our engineers in order to have a Do It Yourself system where all parts of our projects fit and work. This had its conceptual and practical problems, as you can imagine. Following is an animation of how it works, but please feel free to dig into it down below.

What are the requirements of the system?

Every year iGEM comes up with dozens of projects with interesting applications, but few of them end up in a prototype. This year Valencia team has gone one step further building a scale prototype for a real application: disinfecting pathogens from water. The final design of our model has come after many hours struggling with ourselves in order to find the cleverest solution.

The prototype and its corresponding final design fulfill several requisites:

• Safety – The most important requirement, it has to be safe for the users and the environment
The team has worked much to avoid operating hazards and risk during construction. First, the corresponding safety measures for doing hardware work, like wearing gloves and using protection glasses were followed. Regarding the operation, it was decided to work with a 12 V energy supply, so there is no electroshock risk. Electrical cables have been protected and have been enough distantly kept from the water flasks. All other hazards related with biosafety have been explained in the corresponding biosafety section (poner link)

• Cost – Economically accessible for the majority of the applications
The total cost for out model is just 150 € (see list below)!

• Size – The dimensions of the apparatus need to be coherent with the disinfected volume and it is desirable to be able to transport it easily.
The size of our prototype is 70 x 55 x 25 cm, it is easily portable in a suitcase and weighs 7 kg.

• Ease of use – No advance technical expertise to be required
Once the cultures are prepared, there is no specific knowledge needed, just wait for clean water!

• Spare parts – The repair or replacement of failed parts should be simple and safe
Most of the elements of our design can be easily found and quickly substituted.

• Autonomous – Renewable energy sources like photovoltaic power generation are ideal to obtain a sustainable supply of energy
With the exception of cell cultures replacement after some time of use, the rest of the equipment can work alone if energy is supplied. With a total estimated energy consumption of 40 W, several renewable energy sources are adequate.

Overall Setup

1. Bacteriocin production system

In this section there are two streams. One flows in a permanent loop and contains the E. Coli resistant bacteriocin producer with own synthesized bacteriocins. The second one passes through the UF membrane, so it is rich in bacteriocins and other small particles.

Constituent elements:

  • Peristaltic pump (PP)
  • This kind of pump is perfect to work with biological cultures, since there is no direct contact between the cells and the mechanical parts of the P and consequently, no cell membrane damage and no temperature increase is expected. The fluid is contained within a flexible silicone tube fitted inside a circular pump casing. This tube is compressed by two rollers attached to the rotor, pulling the fluid in one direction.

    Pump setup detail

    Our PP comes from a used hemodialysis machine with an out of order motor. We replaced it with a flamboyant Volkswagen Golf windscreen wiper motor. In order to assemble the wiper motor with the pump we used following additional material:

    The motor is coupled with threaded rods to a reinforced steel plate, which at the same time supports the PP. Thanks to the threaded rods we can regulate the distance from the motor to the pump and the angle of the shaft. In order to use the original shaft of the pump, we welded it to a nut with the same metric threat to the one of the motor shaft, achieving a cheap functional peristaltic pump.

  • Module of Bacteriocins Separation (MoBS)
  • The aim of this device is to separate the bacteriocins from the E. Coli harvest. There are marketed ultrafiltration modules of around 1000 € but after several designs and trials, we found a fully functional low-cost solution.

    Bacteoricin separator

    Our final MoBS device consists of different brass piping fittings. The main element is a 1’’ pipe tee with two reduced elbows where the central exit of the tee has an amplifier fitting connected to a hexagonal screw top. On the inside top surface the 2 ’’ Ø UF membrane is supported and its outline part is glued to the metal with a thin layer of neutral silicone, sealing and fixing the membrane at the same time. Both elbows have another fitting to end in a threaded nipple with ¼ ’’ hose barb whereby the flow which doesn’t pass the membrane comes and returns to the E. Coli bacteriocin production flask through polyurethane tubes.

    The UF membrane is a flat NADIR® polysulfone membrane which is chemical and thermal stable and efficiently working for a wide pH range. Its MWCO value is 20 kDa, so bacteoricin peptides are able to pass the membrane in contrast to other big molecules and cells that are blocked by it. The incoming and outcoming flow of the tee are perpendicular to the permeate so that depositions on the membrane surface are prevented.

    The pump is switched off when the proper concentration of bacteriocins is reached in the contaminated water.

2.Controller of pH (CopH)


This is the section of the whole system that controls the activity of the bacteriocins. It connects the flask containing pH regulating cyanobacteria with the water vessel. CopH consists of a ½ ’’ M-F pipe union with and ending fitting for polyurethane tubes. Inside the pipe union a dialysis membrane has been included to permit small molecules and ion exchanges but avoiding the pass of big molecules, peptides and bacteria, allowing proton transient transfer along the tubes that link both flasks. In this way, the pH value of the system is directly controlled by the photosynthetic bacteria to permit or inhibit the peptides actuation.

pH transmitter

The dialysis membrane is a SnakeSkin™ Pleated Dialysis Tubing with a 3,500 MWCO value. We cut the tubing dialysis to form a ½ ’’ round and flat membrane and put it inside the pipe union, held by two equal size toric joints. Contrary to the UF membrane, this type is active at both sides of its surface.

All tubes with the exception of the one that is compressed by the peristaltic pump are made of polyurethane, while the one inside the PP is softer, made of silicone, so that the rotor is able to squeeze properly this tube. All tubes have a ¼ ’’ Ø. In addition, we have included throttle valves to all tubes that link the different functional parts of the machine (that means after the UF membrane and before the dyalisis one) as safety elements to be able to regulate the flows. Finally, it is critically required to include a throttle valve in the tube returning to the bacteriocin flask after the MoBS to be able to achieve enough P for the UF membrane separation process.

3.Hardware work


The main equipment of the apparatus has been described above. However, there are several extra instruments required to allow cultures to grow and develop.

  • Magnetic stirrer
  • The agitation of the medium is essential for a correct homogenization of the bacteria and the compounds dissolved in it.

    Our device is built with a computer fan and a neodymium magnet coming from a hard disk bracket. We stuck the neodymium-iron-boron alloy magnet on the axis fan, so when it is switched on, the magnet is permanently in movement, creating a changing magnetic field. The fan is put inside a watertight box for electric cabling. A stir bar is used to create the agitation in the flasks without affecting the biological harvest. Linked to each fan there is a potentiometer with which the desired speed can be reached.

  • Illumination
  • The photosynthetic bacteria need light to do photosynthesis and so to change pH. Our illumination system consists of the LED lamp of a flashlight coupled to a switch.

  • Temperature Control System
  • E. Coli needs a 37 ºC medium to grow up at the maximum ratio. The team built a thermostat which keeps this temperature constant.

    In the following the different parts of the thermostat, including the control circuit are listed:

    Circuit diagram


    The operational amplifier has two inputs, the non-inverting V+ and the inverting input V-. Moreover, the output is different to zero when the inputs are non equal.

    In this way we can check the resistance of the thermal sensor, a thermistor, at 37 ºC and set the variable resistance to this value. Hence when the temperature reaches our target temperature, we have the same inputs at both entries and therefore the output from the amplifier is zero, opening the relay and so switching off the ceramic resistance that is heating up the biological harvest. The whole ceramic device is covered by a copper casing and sealed with silicone so it is safe to put it directly in water.

    After the initial heating up phase, the resistance will be switched on just when the temperature of the solution given by the thermistor is below the target temperature. In this case, the ceramic resistance is switched on by the relay again and it restarts heating up the medium.

    Heating resistance

  • Energy supply
  • Several trials were tested using solar energy provided by our photovoltaic module to show that renewable energy sources are a future option for many synthetic biology applications. In other experiments, we have utilized a PC power supply for the different instruments of the disinfection machine. Depending of the device we have use one of the three available voltages (12, 5 and 3,3 V):

    • 12 V: Peristaltic pump, Temperature Control System

    • 5 V: Lamp, Magnetic stirrer

    Much work has been done to avoid electrical related risks, like film covering of cable welded unions. All cables have been together put inside a water tightbox. Finally three plug terminals have been adapted to the energy supply and to the tightbox to facilitate the connections and making possible to transport the supply energy separately.

      Total prototype cost

      One of the goals of the project is to create a working prototype that can be designed and built with low resources. We achieved this goal as our model just costs 150 €!

      Moreover, all the components can be easily found or bought in different stores with the exception of the two different used membranes that can be purchased online.

      Many of the elements below listed were received as donation, but though an estimated cost has been given as reference expenditure.


      The elements that have zero cost were taken from scrap