Team:Groningen/fluorimetry

From 2011.igem.org

(Difference between revisions)
(Created page with "{{HeaderGroningen2011}} =Fluorimetry protocol= <br> <br> Inoculate 10ml M9 medium+ antibiotics + 1ml 2% casamino acids and grow the cultures overnight at 37°C. <br> Grow a logf...")
Line 1: Line 1:
{{HeaderGroningen2011}}  
{{HeaderGroningen2011}}  
 +
=Fluorimetry=
 +
<br> The OD600 and fluorescence of a great number of samples can be measured the same time with the fluorimeter.
 +
<br> We used it for measuring PBADaraC-cI-LVA+PcI-GFP with different concentrations of arabinose as an induction
 +
<br> signal
 +
<br>
=Fluorimetry protocol=
=Fluorimetry protocol=
<br>
<br>
Line 8: Line 13:
<br> The fluorimeter will measure the OD600+ fluorescence every 15 minutes.
<br> The fluorimeter will measure the OD600+ fluorescence every 15 minutes.
<br>
<br>
-
 
{{FooterGroningen2011}}
{{FooterGroningen2011}}

Revision as of 17:18, 21 September 2011


Fluorimetry


The OD600 and fluorescence of a great number of samples can be measured the same time with the fluorimeter.
We used it for measuring PBADaraC-cI-LVA+PcI-GFP with different concentrations of arabinose as an induction
signal

Fluorimetry protocol



Inoculate 10ml M9 medium+ antibiotics + 1ml 2% casamino acids and grow the cultures overnight at 37°C.
Grow a logfase to an OD600 of 0.4.
Dilute in a way that the OD600 is decreased to a value of 0.004/
Add 300μl of the diluted culture into a well.
The fluorimeter will measure the OD600+ fluorescence every 15 minutes.