Team:Wageningen UR/Project/DevicesAdditional

From 2011.igem.org

(Difference between revisions)
(Custom fluidic device designed by Team Wageningen UR to measure oscillations)
 
(2 intermediate revisions not shown)
Line 24: Line 24:
{{:Team:Wageningen_UR/Templates/Style | text= __NOTOC__
{{:Team:Wageningen_UR/Templates/Style | text= __NOTOC__
-
The following pictures depict the dimensions of the flow device and it,s functional components in micro meters. These pictures dont include the outflow port of the bottom chamber, the dimensions of this port are the same as the inflow port of the bottom chamber. For an up to date google sketch-up file of the final design click here.
 
-
[[File:chamber.jpg|900px|]]
+
 
 +
 
 +
The following pictures depict the dimensions of the flow device and it,s functional components in micro meters. These pictures dont include the outflow port of the bottom chamber, the dimensions of this port are the same as the inflow port of the bottom chamber. For an up to date google sketch-up file of the final design click [http://sourceforge.net/projects/theconstructor/files/ here].
 +
 
 +
 
 +
[[File:chamber.jpg|770px|]]
Dimensions flow chamber.
Dimensions flow chamber.
-
[[File:corner.jpg|900px|]]
+
[[File:corner.jpg|770px|]]
Height bottom chamber and dimensions of the nodge which is necessary for having the mico-dish square in the chamber.  
Height bottom chamber and dimensions of the nodge which is necessary for having the mico-dish square in the chamber.  
-
[[File:inside 6.jpg|900px|]]
+
[[File:inside 6.jpg|770px|]]
Dimensions of the bottom chamber and micro-sieve socket.   
Dimensions of the bottom chamber and micro-sieve socket.   
-
[[File:inside 7.jpg|900px|]]
+
[[File:inside 7.jpg|770px|]]
Dimensions of micro-sieve socket from top. Nodges have the same function and  dimensions as the nodge of the micro-dish.
Dimensions of micro-sieve socket from top. Nodges have the same function and  dimensions as the nodge of the micro-dish.
-
[[File:inside.jpg|900px|]]
+
[[File:inside.jpg|770px|]]
Dimensions of outflow channel and port of top chamber.
Dimensions of outflow channel and port of top chamber.
Line 53: Line 57:
-
[[File:inside2.jpg|900px|]]
+
[[File:inside2.jpg|770px|]]
Radius of ports,in and out flow channel.
Radius of ports,in and out flow channel.
-
[[File:inside3.jpg|900px|]]
+
[[File:inside3.jpg|770px|]]
Radius of flowthrough channel and port.
Radius of flowthrough channel and port.
-
[[File:inside4.jpg|900px|]]
+
[[File:inside4.jpg|770px|]]
Dimensions of flowthrough channel and port.
Dimensions of flowthrough channel and port.
-
[[File:outsidedimensions.jpg|900px|]]
+
[[File:outsidedimensions.jpg|770px|]]
Outside dimensions of flow device.
Outside dimensions of flow device.
}}
}}

Latest revision as of 13:01, 20 September 2011

Building a Synchronized Oscillatory System

Custom fluidic device designed by Team Wageningen UR to measure oscillations



The following pictures depict the dimensions of the flow device and it,s functional components in micro meters. These pictures dont include the outflow port of the bottom chamber, the dimensions of this port are the same as the inflow port of the bottom chamber. For an up to date google sketch-up file of the final design click [http://sourceforge.net/projects/theconstructor/files/ here].


Chamber.jpg

Dimensions flow chamber.


Corner.jpg

Height bottom chamber and dimensions of the nodge which is necessary for having the mico-dish square in the chamber.


Inside 6.jpg

Dimensions of the bottom chamber and micro-sieve socket.


Inside 7.jpg

Dimensions of micro-sieve socket from top. Nodges have the same function and dimensions as the nodge of the micro-dish.


Inside.jpg

Dimensions of outflow channel and port of top chamber.


Inside2.jpg

Radius of ports,in and out flow channel.


Inside3.jpg

Radius of flowthrough channel and port.


Inside4.jpg

Dimensions of flowthrough channel and port.


Outsidedimensions.jpg

Outside dimensions of flow device.