Team:Wageningen UR/Project/ModelingProj1

From 2011.igem.org

(Difference between revisions)
(Modeling synchronized oscillations)
(Modeling synchronized oscillations)
Line 100: Line 100:
-
=== Conclusions for our system ===
+
=== Preliminary conclusions for our system ===
The first observation from the model was that, for oscillations to occur, the flow rates may not be too fast, especially at lower cell densities. Since the device used for our system has larger dimensions than the microfluidic device used by Danino et al. the flow rates in the velocities required could not be achieved by varying height differences alone. <!-- Further information can be found in the information about the [[Team:Wageningen_UR/Project/Devices#Setup| platform used to measure oscillations.]] -->
The first observation from the model was that, for oscillations to occur, the flow rates may not be too fast, especially at lower cell densities. Since the device used for our system has larger dimensions than the microfluidic device used by Danino et al. the flow rates in the velocities required could not be achieved by varying height differences alone. <!-- Further information can be found in the information about the [[Team:Wageningen_UR/Project/Devices#Setup| platform used to measure oscillations.]] -->
Line 115: Line 115:
=== Expansion of the model for the double tunable oscillatory construct ===
=== Expansion of the model for the double tunable oscillatory construct ===
-
To accomodate the idea of the [[Team:Wageningen_UR/Project/CompleteProject1Description| double tunable oscillator]], the original set of delay differential equations shown above was expanded by two additional differential equations showing the behaviour of the lacI and tetR repressor. The equations for the LuxI and AiiA production were then expanded by a term showing the influence of the corresponding repressor lacI for LuxI and tetR for Aiia respectively. Below the adjusted set of differential equations is shown.
+
To accomodate the idea of the [[Team:Wageningen_UR/Project/CompleteProject1Description| double tunable oscillator]], the original set of delay differential equations in the paper was expanded by two additional differential equations for the LacI and tetR repressors and the equations for the LuxI and AiiA production were adjusted to take the influence of the corresponding repressors lacI for LuxI and tetR for Aiia respectively into account. Below the adjusted set of differential equations is shown.
'''Top: ''Adjusted set of differential equations for the double tunable oscillator''
'''Top: ''Adjusted set of differential equations for the double tunable oscillator''

Revision as of 19:33, 19 September 2011

Building a Synchronized Oscillatory System

Modeling synchronized oscillations


Mathematical model of the Hasty construct

Since our bio bricked oscillatory system is based on the circuit published by Danino et al. in the paper [http://www.nature.com/nature/journal/v463/n7279/abs/nature08753.html “A synchronized quorum of genetic clocks”], in our team commonly referred to as the "Hasty construct", our first model of the system is a reproduction of the mathematical model in the [http://www.nature.com/nature/journal/v463/n7279/suppinfo/nature08753.html supplementary information] accompanying the publication mentioned. In their simulations, Danino et al. used a set of four delay differential equations, which we also used as starting point for our modeling work.

The steps (transcription, translation, maturation etc.) from the luxI and aiiA genes to the corresponding proteins are not modeled separately, but the delay of the correlation between the internal AHL concentration, which triggers the expression of the genes, and the corresponding AiiA and LuxI is simulated by a Hill function which takes the history of the system into account, i.e. the concentration of AHL at the time it binds to LuxR to form the activation complex.



back to top


Writing a modeling tool in matlab

Oscillation GUI WUR.png

Fig.1: GUI of the matlab modeling tool created by team Wageningen UR

For the first simulations, the same parameters were used as in the cited paper, the only variables being the cell density and flow rate. To get an idea about the different conditions in which oscillations could occur, our team created a script for a matlab modeling tool which uses nested for-loops to vary the flow rate and cell density over a range of values. The resulting tool allows the user to enter the range in which the variables should be varied. The tool then iterates over the values and plots graphs of all combinations possible for that range of values. Figure 2 shows an example output of the tool.


Example output graphs WUR.png

Fig.2: Variation of output graphs depending on the different starting conditions


back to top


Preliminary conclusions for our system

The first observation from the model was that, for oscillations to occur, the flow rates may not be too fast, especially at lower cell densities. Since the device used for our system has larger dimensions than the microfluidic device used by Danino et al. the flow rates in the velocities required could not be achieved by varying height differences alone.

Furthermore, an interesting observation was that applying a flow rate over the cells was not essential to obtain ocillations. Figure 3 shows how, according to the model, oscillations can potentially occur at 0 flow rate. Interesting is that this happens only at high cell densities.

Model0flow WUR.png

Fig.3: Graphs showing oscillatory behaviour increasing with cell density even when the flow rate is set to 0

Disregarding the strictly mathematical model, some more conclusions were drawn from modeling work as to whether to use a micro-dish or micro-sieve as platform for measuring oscillations. This is described in more detail in the section about the setup of the device.


Expansion of the model for the double tunable oscillatory construct

To accomodate the idea of the double tunable oscillator, the original set of delay differential equations in the paper was expanded by two additional differential equations for the LacI and tetR repressors and the equations for the LuxI and AiiA production were adjusted to take the influence of the corresponding repressors lacI for LuxI and tetR for Aiia respectively into account. Below the adjusted set of differential equations is shown.

Top: Adjusted set of differential equations for the double tunable oscillator

Since the lacI repressed hybrid promoter used for this system was designed by the [http://parts.mit.edu/igem07/index.php/Tokyo/Works Tokyo iGEM 2007] team, the equations were derived according to their model. The tetR repressor was then modeled using the same template.


back to top