Team:Uppsala-Sweden/Project/Data

From 2011.igem.org

Revision as of 22:36, 21 September 2011 by Tomasdalmo (Talk | contribs)

Visit our blog:

USblog.png










http://igem2011uu.blogspot.com


Test for light-sensor and promoter characterization



Characterization is an important aspect of synthetic biology and it is a way of obtaining how well the expression of the system really is. Therefore we have designed two tests to perform characterization of the parts we are going to use. Both types of test are based on the expression levels of BFP. The first test is done in order to characterize the promoters that we are using in our project. The second test is done to test the output of our light sensing system. The expression levels will in both cases be measured using flow-cytometry. Here the specific details of how the test has/will been performed depending on its type.

Promoter testing


The first test was done to see the strength of the promoters used. From the beginning it was meant to be a characterization of the promoter Pt5lac that we provide to the partsregistry. Though since the other promoters we are using which were gained from the partsregistry was not characterized yet, the decision was made that we would have to characterize all the promoters we use. Since, as said in our opinion characterization is a really important aspect of the working approach in synthetic biology. Every construct was made according to the approach provided by the measurement page in partsregistry besides from that the expressed protein was BFP. This means that the backbone pSB3K3, the RBS B0032 and BFP were used in every construct. The promoters tested were pT5lac, PcpcG2, PLlacO, J23113, PfixK and as reference promoter J23101. The assemblies were done according to the picture.

The actual test was done in a somewhat different way than that presented at the partsregistry. Here we use flow-cytometry which also results in that we did not use M9 media to grow the cells but used LB instead. Also when it comes to the time of incubation of the selected colonies were 10 hours and no dilutions were made except for the settings requirements of the FACS machine.


System output tests


This test will be fully compatible with our system. The only change is that every constructed output will be done with BFP as output instead of the color output in order to get a preference of how efficient the light-sensors are. Since there are no fully functional sensor, no tests has been able to be performed. Though Both the corresponding blue and yellow output is ready to be used.