Team:BU Wellesley Software/Notebook/AlbertoNotebook

From 2011.igem.org

(Difference between revisions)
Line 19: Line 19:
*Four GFP devices (each with a different promoter) have been made
*Four GFP devices (each with a different promoter) have been made
<br>
<br>
-
Up until last week, we have been having mixed results with the use of pelleted cells to transform ligation reactions. The appearances of bacterial colonies, which signify the success of transformed ligated parts, are not consistent and have an extremely low yield. The usage of positive control does not seem to produce numerous colonies, meaning that there is something wrong along the way. So we tried to look for several possible explanations on this issue; we later read that ligation time or insert to vector ratio can possibly affect the ligation success. Several ligation attempts are then tried at room temperature for either 30 minutes, 1 hour, or overnight. The insert to vector ratio was also varied from 1:1 to 1:8. We expected to find a normal distribution for the number of colonies obtained around the most optimal condition. Because only 2uL of each ligation reaction is used in the transformation, I also transformed 2uL from the leftover of my E0430_R0040 (YFPc_pTet) ligation reaction with the Alpha Select Cells (we received this cell last week but transformation attempt using them had not been successful).
+
Up until last week, we have been having mixed results with the use of pelleted cells to transform ligation reactions. The appearances of bacterial colonies, which signify the success of transformed ligated parts, are not consistent and have an extremely low yield. The usage of positive control does not seem to produce numerous colonies, meaning that there is something wrong along the way. So we tried to look for several possible explanations on this issue; we later read that ligation time or insert to vector ratio can possibly affect the ligation success. Several ligation attempts are then tried at room temperature for either 30 minutes, 1 hour, or overnight. The insert to vector ratio was also varied from 1:1 to 8:1. We expected to find a normal distribution for the number of colonies obtained around the most optimal condition. Because only 2uL of each ligation reaction is used in the transformation, I also transformed 2uL from the leftover of my 3:1 insert to vector, 30 minutes bench top, E0430_R0040 (YFPc_pTet) ligation reaction with the Alpha Select Cells (we received this cell last week but transformation attempt using them had not been successful) and spread 2 plates with it.
 +
 
 +
Surprisingly, none of the ligation attempt produced any significant result - except for the 2 transformation plates that use the Alpha Select Cells. These plates contained enormous, uncountable, amount of colonies. This was indeed surprising, but then we decided to transform several ligation reactions (the leftover from what we prepared on Monday) and checked to see if the use of Alpha Select Cells will produce a consistent ligation success. On the next day, we found out that this is exactly what happened. The only problem only occurred in the fluorescence composite parts that were ligated with the R2000 promoter. They either produced a small amount of colonies or nothing at all. Because R2000 is described on the Parts Registry as working well with E0240 (GFPc), it may simply not work well with other parts. Hence, we all decided to stop using R2000 for parts other than GFPc.
 +
 
-
Surprisingly, none of the ligation attempt produce any significant result - except for the transformation plate that uses the Alpha Select Cells.
 

Revision as of 16:37, 25 July 2011

2011 IGEM BU_Wellesley Wet Lab Notebook
My name is Alberto Purwada, a rising junior majoring in Biomedical Engineering (BME) at Boston University. This is a weekly log of my experience participating in the BU Wet Lab Team for the 2011 International Genetically Engineered Machine Competition (IGEM).

Contents

Timeline

7/18/2011-7/24/2011

Summary:

  • Different insert to vector ratio and reaction time did not seem to solve our ligation issue
  • The ligation problem was solved with the use of Alpha Select Cells
  • Four GFP devices (each with a different promoter) have been made


Up until last week, we have been having mixed results with the use of pelleted cells to transform ligation reactions. The appearances of bacterial colonies, which signify the success of transformed ligated parts, are not consistent and have an extremely low yield. The usage of positive control does not seem to produce numerous colonies, meaning that there is something wrong along the way. So we tried to look for several possible explanations on this issue; we later read that ligation time or insert to vector ratio can possibly affect the ligation success. Several ligation attempts are then tried at room temperature for either 30 minutes, 1 hour, or overnight. The insert to vector ratio was also varied from 1:1 to 8:1. We expected to find a normal distribution for the number of colonies obtained around the most optimal condition. Because only 2uL of each ligation reaction is used in the transformation, I also transformed 2uL from the leftover of my 3:1 insert to vector, 30 minutes bench top, E0430_R0040 (YFPc_pTet) ligation reaction with the Alpha Select Cells (we received this cell last week but transformation attempt using them had not been successful) and spread 2 plates with it.

Surprisingly, none of the ligation attempt produced any significant result - except for the 2 transformation plates that use the Alpha Select Cells. These plates contained enormous, uncountable, amount of colonies. This was indeed surprising, but then we decided to transform several ligation reactions (the leftover from what we prepared on Monday) and checked to see if the use of Alpha Select Cells will produce a consistent ligation success. On the next day, we found out that this is exactly what happened. The only problem only occurred in the fluorescence composite parts that were ligated with the R2000 promoter. They either produced a small amount of colonies or nothing at all. Because R2000 is described on the Parts Registry as working well with E0240 (GFPc), it may simply not work well with other parts. Hence, we all decided to stop using R2000 for parts other than GFPc.



7/11/2011-7/17/2011

Summary:

  • Although most gel extraction samples had low DNA concentrations, gel electrophoresis proved that they indeed contain the DNA (i.e. cut plasmid).
  • The use of new E. coli cells in concentrated amount in the transformation of ligation reactions resulted in a few plates that contained colonies.
  • The ligated parts showed reduced efficiency in both plasmid prep and miniprep.
  • Further efforts are being done to verify the ligated parts and the possibility of false positive.


I ligated and transformed the ligation reaction from last week. Unfortunately, only the single cut GFP Composite (Bba_E0240) showed a single colony, despite the fact that it was supposedly the positive control. The ligation reaction for this particular plate was done on the bench top at room temperature for 30 minutes. I initially planned to verify that ligated plasmid by comparing it with uncut GFP Composite (Bba_E0240). But I decided against it because nobody was planning to do gel on that day and running just one sample seemed inefficient. We then had a discussion where we realized the following: Supercoiled plasmid can usually be transformed easily. But ligated plasmid is not supercoiled, hence its relatively large size, making such plasmid more difficult to enter the bacteria through transformation. We can now understand why our bacteria transformed BioBrick parts easily, but had problems with the ligated parts. The amount of bacteria in each reaction tube might not be enough to uptake the ligated parts. To solve this problem, we got a new E. coli batch from MIT that contains 10^2 to 10^3 more bacteria in it. One attempt at transforming ligation reaction using those new cells resulted in the two plates with very small colonies. They were almost invisible to the naked eye, but additional incubation allowed these colonies to be clearly visible.

<picture to be put here>

Assuming that higher amount of cells can fix our ligation problem, I transformed several past overnight ligation reaction that consist of: GFP Composite + R2000, GFP Composite + pCat (I14033), GFP Composite + pTet (R0040), Positive Control (J23101), and Negative Control (E. coli on plain LB). The transformation protocol used here was quite dissimilar from the regular one because 800 uL of the new E. coli cells would be concentrated into 200 uL by centrifugation and resuspension. The heat shock would be done on the heating block for 30-45 seconds and the recovery would take place inside the shaker. After overnight incubation at 37 degree, the Positive Control and Negative Control plates contained numerous colonies. I initially though that the other plates did not contain any colony, but Traci took a look at them and realized that one of the plate (Bba_E0240 + Bba_I14033) contained small colonies. Meanwhile, plates that were made with more concentration of cells (~2 mL) had more visible colonies on it. So Traci told me and Kyle to transform some ligation reactions into 3 and 4 mL of pelleted cells, respectively. I did that with Vanessa's overnight ligation of YFP Composite + pCat (Bba_E0430 + Bba_I14033) and my quick ligation of GFP Composite + R2000. The results were still unreliable as only the latter had colonies, but at least something worked.

I prepared plasmid preps for the Bba R2000_E0240 and Bba I14033_E0240, then incubate them inside the 37 degree shaker overnight. I found out on the next morning that the plasmid preps were not as opaque as usual. They were at most 60-70% cloudy-looking, signifying that the bacterial amplification in this LB broth liquid culture was not optimal. When I did nanodrop quantification on the plasmid obtained from my plates (the first eight), Kyle's (the next four) and Vanessa's (the last one), the obtained values seemed smaller than our other plasmids.

Tube Name DNA Concentration 260/280 260/230
R2000_E0240_1 15 1.82 0.81
R2000_E0240_2 15.5 1.79 1.19
R2000_E0240_3 7.3 1.86 1.70
R2000_E0240_4 11.9 1.56 0.83
I14033_E0240_1 5.3 1.54 2.25
I14033_E0240_2 3.8 1.97 1.19
I14033_E0240_3 9 1.56 0.05
I14033_E0240_4 12.4 1.44 0.72
K156010_B0015_1 22 1.61 0.76
K156010_B0015_2 23.2 1.68 0.67
K156010_B0015_3 7.2 1.83 1.04
K156010_B0015_4 6.8 1.45 1.11
R2000_E0430 23.6 1.56 0.68

Despite the fact that we obtained colonies from transformed ligation reactions, we tried to approach this result cautiously. Some checked on the Ampicillin and Kanamycin negative control plates to verify the ability of these antibiotic infused LB plates in selectively prohibit bacterial growth (the plates are all good). Some planned to conduct ligation with the addition of CIP into the backbone to check the possibility of false positive (it was still ongoing at the time). I did a quick verification attempt with gel electrophoresis to both determine the availability of DNA and check the fragment size. I used the samples from the mini prep with the highest concentration and ran it against the backbone plasmid. This means that if I were to check on R2000_E0240, I would run the sample against R2000 because this promoter was used as the backbone/vector with the E0240 used as the insert. But only the R2000_E0240 part produced a visible on the gel so that I only prepared frozen stock for this one.

<gel picture to be put here>

In the meantime, I was quite concerned that the small DNA concentration in the gel extraction samples may mean nothing but false positive. So I ran gel electrophoresis using several samples and each well was filled with 10 uL of the samples. The resulting gel picture had extremely faint bands, so my effort to increase their visibility also caused the DNA ladder to be overexposed. But this did not concern me because I only wanted to verify the existence of DNA, not the size. Only DNA would appear as glowing bands because they could be bounded with the SIBR dye. The most important thing here is that we can now be assured that the DNA was not lost in gel extraction.

<gel picture to be put here>

7/4/2011-7/10/2011

The transformed plates from last week did not contain the usual colonies. Instead, each plate had a thin layer of bacteria lawn* (*= uncountable colonies, making it appears film-like) and it smells far stronger, albeit similar, to the usual E. coli culture. While we never seen a plate that contains bacterial lawn before, we found out later that it was not the transformed bacteria because of the following: First, the negative control plate also showed the same bacterial lawn growth. That means the plate was not doing its job in antibiotic-based selection. Because all the plates showed similar characteristic, the plate either lack kanamycin or it was added when the agar mixture was still hot, thus degrading the antibiotic. Second, the plasmid prep did not show any growth, meaning that the bacteria did not prefer 37 degree Celsius (unlike E. coli). This problem appeared suddenly because we just made the kanamycin plate the previous day. Another problem also appeared when Shannon was about to transform several more bench top ligation reaction when Kyle realized that the LB broth was contaminated. There was a yellow/transparent clump of spore-like materials lying at the bottom. This is bad because another set of ligation was transformed with that LB broth on the previous Sunday, meaning that its quality would be compromised as well. We found out later that these plates did not grow either. In order to avoid such problem, we decided to remake the LB broth along with the plates. We did negative control on the new Ampicillin and Kanamycin plates and they turned out fine. I then divided the LB broth into several aliquotes, each for one team member. This is done not only to improve efficiency (no need to transfer broth from big flask to the small one every time) but also to reduce the risk of contamination.

Aliquoted LB broth
Transformed plate containing bacteria lawn
Preparing tubes for the competent cells











In terms of our overall progress, everything tended to work well up until ligation. While we could not verify the condition of our ligation, they did not transform well. So Traci decided to prepare a new batch of E. coli cells, especially because our stock has been running out as well. Some other people decided to prepare a new set of plasmid prep by either using old plates or streaking new plates. In such cases, transformation never became a problem for us. So we figured out that the problem should be caused by ligation. Traci then ordered a package of Quick Ligation. I also tried doing ethanol precipitation for the gel extraction samples with extremely low DNA concentration, which supposedly compress the DNA into an extract of smaller amount but higher concentration. But it did not work either.

On my own personal attempt at creating a device using GFP composite, I had not been able to progress further either due to ligation problem. So with all the new tools in hand (cells, plates, LB broth), I decided to start from the beginning – get new mini prep samples, digest the plasmid, and tried different ligation method. In this case, I limited myself to only use GFP Composite (Bba_E0240) and the suitable promoter (Bba_R2000). I also tried to learn more about the ligation problem by cutting both GFP composite and R2000 Promoter with only one restriction digest enzyme, X and S respectively. They will serve as a "positive control", because they are supposed to be easy to ligate. I prepared 3 ligation reactions for one type of sample, each reaction is done through either one of the following ligation protocol: 16 C for one hour, room temperature/bench top for 30 minutes, or bench top using quick ligase for 5 minutes. The insert to vector ratio used was 1 to 3 and the heat inactivation step would be skipped here.

Restriction Digest

Well Number Biobrick Name Part Type Description
1 DNA Ladder - -
2 Bba_E0240 GFP Composite Uncut

6/27/2011-7/3/2011

Utilizing the digested plasmid from last week, I ran gel electrophoresis to separate the fragments of the digested plasmids from last week. It was apparent that the GFP composite had been successfully cut, which means that we had solved the problem with restriction digest.

Restriction Digest
1. DNA Ladder
2. Promoter (Bba_R2000.1)
3. Promoter (Bba_R2000.1) - Cut
4. Promoter (Bba_R2000.2) - Cut
5. Promoter (Bba_R0040.1)
6. Promoter (Bba_R0040.1) - Cut
7. GFP Composite (2) (Bba_E0240.1)
8. GFP Composite (2) (Bba_E0240.1) - Cut
9. GFP Composite (2) (Bba_E0240.2) - Cut
10. GFP (BBa_J52028) 
11. GFP  (BBa_J52028) - Cut
12. DNA Ladder

Despite our success with the restriction digest, one question still remains: why did the bands look faint, while the DNA ladder was extremely bright? We later found out that this issue was caused by using DNA ladder without diluting it first. Once we mixed the DNA ladder and water with 1:4 ratio, the bands on the gel fluoresced with the same intensity, allowing us to clearly verify their relative position according to the DNA ladder.

Progressing to the next step, we found numerous problems with the ligation and we then tried to isolate the error sources systematically. We realized that we had ignored the number of base pairs for the insert and vector ratio calculation. This mean that the unexpected band size from the GFP + Terminator composite part could possibly result from bad ligation. I did ligation again with this new formula, but nothing grew. We then tried using the improved calculation method, where the vector mass were kept constant and as close to 50 ng as possible. In the meantime, Margaux successfully did the ligation, which could be verified by the red tinted colonies. From her experiment, we found out that the amount of ligase enzyme did not matter. Kyle also did ligation and found out that two ligation incubation protocols did not yield different result. Nevertheless the yield was extremely small as only 1 or 2 plates show bacterial growth. In addition, there was at most 1 or 2 colonies found on each of those plates.

We then tried to do ligation with different protocol, where the ligation reaction will be incubated in 16 degrees overnight, using the 5 samples prepared with the revised calculation. One of these samples, Bba_R2000_E0240 (Promoter+GFP Composite), underwent ethanol precipitation to increase its concentration. While the concentration of its individual part was very small, ethanol precipitation can create a significantly small sample with high concentration. We expected this approach to allow a better attachment between the sticky parts, even though the small volume prohibit us from mixing the parts based on the previously established ratio. The result were transformed on Sunday and we expected the plates to be ready by next Tuesday.

6/20/2011-6/26/2011

On 6/21, we had the first Computational + Wet Lab joint meeting where everyone presented an update on his/her progress so far. We also talked on what further improvement can be implemented and how to proceed to the next phase of the project. Based on the meeting, we realized the need to figure out how to put more media files into the online notebook, label the gel, and organize a clearer division of labor. I plan to work mostly on part/device creation, especially on part characterization and data entry for the BU Registry. Professor Densmore also mentioned that we should write basic laboratory protocols as future references for new people, verification method to determine if things are working, and troubleshooting method in case the experiment yields unusual result.

But the most important thing that came from the meeting was the new objective: creating 4 biological devices for each fluorescent protein. In order to achieve that, we would like to utilize 2 different approaches. The first one is a 'Bottom Up Approach' where we will continue attaching fluorescent protein gene to terminator, then putting them together with RBS before finally combining the resulting composite part with a promoter. While this method is going to take longer time and require more effort, it will allow us more opportunity in creating a fully customizable plasmid. The second one is a 'Composite Approach' where we will obtain premade composite parts from the IGEM plate and combine them with other part to save time. The advantage from this method is the ability to create a working biological circuit in a shorter steps and reduce any possible chance of error. I plan to work mostly on the second approach, so I will try to combine several types of promoter with composite GFP gene that already has a RBS and a Terminator.

On the day before the meeting, I was actually working on trying to combine a cut RBS with a composite GFP+Terminator part. Using the previously prepared GFP (BBa_J52028) + Terminator (BBa_B0015) composite part, I did restriction digest on them using the enzyme X and P. I predicted that the GFP+Terminator will be cut away from the rest of the backbone so that the gel electrophoresis will produce a ~700 bp fragment (GFP+Terminator) and a ~3000 bp fragment (the backbone). However, the gel did not produce the expected result: while a faint second band was indeed visible, it was too close to the first one, meaning that this band was too big to be a GFP+Terminator fragment. I decided to carry on this work along with the new 'Composite Approach'. I did restriction digest on YFP composite (Bba_E0430), GFP composite (Bba_E0240), promoter (Bba_R2000), terminator (Bba_B0015), and the previously prepared GFP (Bba_J52028) + Terminator (Bba_B0015) part. For some yet to be determined causes, the YFP and GFP composite were not digested properly as no second band was visible. The GFP+Terminator produce a weird result like before.

I tried to do the same thing for the second time with larger volume, because Traci told us that the nanodrop quantification result from the extracted gels could be improved by using more sample instead of the constant ~10 uL that we had been using all this time. The pictures of the result can be seen below. We were still unable to see any separated band for the cut YFP and GFP composite part. Some promoters and terminators were successfully cut, but our previously made GFP+Terminator composite parts did not seem to produce the expected band and the same thing happened with the parts that encode fluorescent proteins.

Restriction Digest 1
Restriction Digest 1:
1. DNA Ladder
2. YFP Composite - Cut
3. YFP Composite - Cut
4. YFP Composite
5. GFP Composite - Cut
6. GFP Composite - Cut
7. GFP Composite
8. Promoter
9. Promoter
10. Promoter
11. Promoter
12. Promoter
13. Terminator - Cut
14. Terminator - Cut
15. Terminator
16. Terminator - Cut
17. Terminator - Cut
18. DNA Ladder
Restriction Digest 2
Restriction Digest 2:
1. DNA Ladder
2. GFP+Terminator - Cut
3. GFP+Terminator - Cut
4. GFP+Terminator
5. GFP - Cut
6. BFP - Cut
7. BFP
8. RFP - Cut
9. RFP
10. DNA Ladder

Suma told us that she previously encountered the same problem and she pointed out that there might be problem with the restriction digest. In double digestion, where we cut the plasmid with 2 enzymes simultaneously, buffer 2 was always used since it has the highest activity in all enzymes combinations. But it turns out that this assumption may not be enough, since the website for New England Biolabs states that different combinations need different buffer and digestion time. So I repeated the restriction digest with this method and cut the following biobricks: GFP composite (Bba_E0240) and promoter (Bba_R2000 & Bba_R0040). The digestion time was 2 hours instead of the usual 1 hour in accordance to the optimization recommendation found in the NEB website. The digested plasmids were then kept in the freezer.

6/13/2011-6/19/2011

  • GFP + Terminator

The starting materials were GFP (BBa_J52028) and Terminator (BBa_B0015). Each of these biobrick underwent restriction digest to cut out the necessary part. Because the GFP gene is large enough to be separated in gel electrophoresis, it was cut out from the backbone with EcoRi and SpeI. In contrast, the terminator is too small for gel separation so it was not separated from the backbone. Instead, the backbone was cut with EcoRI and XbaI. For the first time, the gel electrophoresis yielded visible results where the cut biobrick plasmid appeared as two bands (the cut region and the leftover). Nanodrop quantification showed that the DNA concentration for each sample was very small as it was between 2-3 ng/uL. The GFP gene and the backbone, which contains the terminator, were combined through ligation reaction.

Throughout these processes, three ligation reactions were made and thus three petri dishes were prepared for each of them. The backbone used here also contains genes that encode for both kanamycin and ampicillin resistance, so petri dishes with either antibiotic can be used for transformation. But since there had been problems with the ampicillin plate where it did not selectively inhibit the bacteria that were not transformed (this was known when the negative control in other experiment yielded positive result), kanamycin petri dishes were used. On the next day, only one out of the three dishes contained bacteria cultures (there were 4 cultures, to be exact). Plasmid prep was done and 12 hours later, the opaqueness from each tube showed that a good number of bacteria amplification had taken place. No string-like substance was found at the end of the pipet tip in each tube. Miniprep was done and the results were: 48.4 ng/uL, 260/280: 1.80, 260/230: 0.89 (composite part 1) and 14.7 ng/uL, 260/280: 1.76, 260/230: 0.91 (composite part 2). The plasmids were kept in the -20C freezer and the corresponding plasmid preps had glycerol added before being stored in 2 places.

  • Isolated Parts

From the recently arrived spring 2011 IGEM plate, the following parts were isolated: Bba_E0430 (RBS+YFP+Promoter), Bba_E0240 (RBS+GFP+Promoter), Bba_R2000 (Promoter that works best with the previous composite parts), Bba_E0020 (ECFP), Bba_E0032 (EYFP), and Bba_K156010 (BFP).

  • Miscellaneous

TAE buffer was prepared from the 50X TAE stock. Approximately 40 LB+Ampicillin agar plates were made because many of the parts contained gene that encode for Ampicillin resistance. Almost all used glasswares were autoclaved and kept for future use. Lab bench was cleaned with 70% ethanol and paper towel. QIAcube was received for demo and would stay for approximately one week from Tuesday (6/14).

6/6/2011-6/10/2011

  • BFP2

Plasmid prep were created from the BFP2 culture plate and incubated for approximately 16 hours for plasmid amplification. The resulting plasmids were isolated by miniprep and quantified with nanodrop. The DNA concentration in the two samples are 16.5 ng/uL and 14.9 ng/uL, respectively. While such values are below the normally acceptable range of 20 and above, we still run electrophoresis on them. No band was detected in the gel.

  • Pbad

Pbad promoter biobrick was obtained from the spring 2010 IGEM plate, and transformed into E. coli bacteria. The bacteria were then plated onto agar-based LB+Ampicillin growth medium. Lots of cultures were found on the next day after the overnight transformation. Instead of uniform appearance, however, each plate was composed of both dark or light colonies. Plasmid prep was done for each of the color type (pipet tip was used instead of metal loop) and each tube was incubated for 12 hours. On the next morning, the tip in each tube was found to contain a spiral, string-like thing and most of the plasmid preps were not opaque. After the miniprep, each of the plasmid was quantified with nanodrop. Their respective concentrations were 10.0 ng/uL and 8.3 ng/uL. They were also found to be free from contaminants (based on the 260/280 and 260/230 values). But none of the samples appeared on the gel after electrophoresis.

In order to understand the problem that had been plaguing our work, we went to a biology lab to view the plasmid preps under compound microscope and conduct gram staining analysis. All plasmid preps seemed to be contaminated with either another type of bacteria (due to differences in shape and size) or unidentified string-like compound. Many of the plasmid preps contain purple-colored bacteria, even though E. coli bacteria are supposed to be pink since they are gram-negative.

Based on these observations, we plan to improve on the lab cleanliness and avoid contamination. One important decision here was to autoclaved all of the pipet. This was done not only to avoid the possibility of contamination in daily experiments but also to ensure that the plasmid preps will properly amplify the plasmid-containing bacteria.

Others

Clotho

[http://www.clothocad.org/ Clotho]

[http://wiki.bu.edu/ece-clotho/index.php/Main_Page Clotho Help/Wiki]

Wet Lab Protocols

Transformation

Ligation

Restriction Digest

Miniprep

Gel Extraction

Media Preparation

NanoDrop DNA Quantification

Competent Cells

External Links

[http://twitter.com/BU_Wellesley Follow BU_Wellesley IGEM Team on Twitter!]

[http://partsregistry.org/wiki/index.php/Main_Page Registry of Standard Biological Parts]

BU_Wellesley IGEM Lab Notebook

BU_Wellesley IGEM Home

Wiki Tools

Upload Files