Team:Kyoto/Measurement

From 2011.igem.org

(Difference between revisions)
(3. Method)
(3. Method)
Line 184: Line 184:
We used the Oregon-RS of Drosophila melanogaster. They were derived from Dr. Fuse's laboratory on 4 August 2011. They were maintained in an incubator at 22℃ on standard cornmeal medium in the ordinary glass bottle <!--(____cm high, ____cm in diameter)--> with a 12h light phase (12:12 light:dark cycle). Flies were aged 2-4 days after emergence.
We used the Oregon-RS of Drosophila melanogaster. They were derived from Dr. Fuse's laboratory on 4 August 2011. They were maintained in an incubator at 22℃ on standard cornmeal medium in the ordinary glass bottle <!--(____cm high, ____cm in diameter)--> with a 12h light phase (12:12 light:dark cycle). Flies were aged 2-4 days after emergence.
-
===3. Method===
+
==3. Method==
Firstly, we gathered 5 flies with a pooter. After that, we removed the tip of the pooter and attached the tip to the bottom end of the Y maze. Then we left the flies intact in the dark for three minutes and counted the number of flies in each tube. In this experiment, we switched both the left and right LEDs on for 2 times alternatively. We ran the experiment 4 times using 2 sets of 5 male flies and 2 sets of 5 female flies.<!--We summed up the number of flies that entered the lighting LED end and opposite end and ran the t test.-->
Firstly, we gathered 5 flies with a pooter. After that, we removed the tip of the pooter and attached the tip to the bottom end of the Y maze. Then we left the flies intact in the dark for three minutes and counted the number of flies in each tube. In this experiment, we switched both the left and right LEDs on for 2 times alternatively. We ran the experiment 4 times using 2 sets of 5 male flies and 2 sets of 5 female flies.<!--We summed up the number of flies that entered the lighting LED end and opposite end and ran the t test.-->

Revision as of 03:28, 6 October 2011

Contents

Measurement

Solubilization of Antibiotics

  1. Mix the following (Final concentration is 50mg/mL).
    • Ampicillin:
      Ampicillin
      1.0g
      MilliQ
      20mL
    • Kanamycin:
      Kanamycin
      0.5g
      MilliQ
      10mL
  2. Dispense 1.1mL of the solution into 1.5mL tubes.
  3. Store in the -20℃ freezer.

Transformation

  1. Unfreeze conpitent cells on ice.
  2. Dry a plate by letting the plate upside down and partly open in incubator.
  3. Add 1µL DNA solution and 20µL compitent cells to 1.5mL tube, let stand for 30min on ice. If few colony is observed, increase the amount of the compitent cells or DNA, but make the amount of DNA not to get over that of the compitent cells.
  4. Heatshock for 60s at 42℃.
  5. Let stand for 2min on ice.
  6. Culture for 1h in preculture medium (LB or SOC medium), and plate by using spreader. Do not heat spreader too much because e.coli will dead for heat.

Sequence

  1. Use Big Dye Terminator 3.1(ABI)
  2. Mix the following
    5xBuffer
    2µL
    Primer (3.2µM)
    1µL
    Template Plasmid 
    200ng
    Big Dye Terminator 3.1
    0.5µL
    MilliQ
    up to 10µL
  3. Let stand for 1min at 96℃.
  4. 35 cycles for 5s at 98℃, for 5s 50℃, and for 2.5min at 68℃.
  5. Add 25µL 100% ethanol and 1µL NAOAC

Measurement of RPU

  1. Cultivate E.coli in M9 media(+ casamino acids) for about 15 hours.
  2. Dispence 2.4ml to each tube.
  3. Centrifuge these tubes (13,000 rpm , 4℃, 1min) and discarded the supernatant.
  4. Add 1.2ml media(- casamino acids) and centrifuged at 4℃ twice.
  5. Centrifuge these tubes again and discarde the supernatant and added 1.2ml media(-casamino acids) at 37 ℃.
  6. Bring up E.coli at 0,5,10,15,20,25,30,60min and extracted RNA and synthesized cDNA.


preliminary experiments

1-1:plotting the standard line


Sample glucose solution(various concentration from 0.20 mM to 1.60 mM)
Blank mixed liquid (240μℓDNS reagent plus 1760㎕distilled water )


  1. added 240㎕ DNS reagent to 80㎕sample
  2. heated it for 5 min in boiling water and then cooled it in water.
  3. added it distilled water by 2ml
  4. measured absorbance in 550nm

The standard curve is shown in fig 1.



1-2:evaluate the affection of medium

we examined the interruption based on the components of media(SOC, plas-grow and M9)


Sample each medium
Blank mixed liquid (240μℓDNS reagent plus 1760㎕distilled water )


  1. added 240㎕ DNS reagent to 80㎕sample
  2. heated it for 5 min in boiling water and then cooled it in water.
  3. added it distilled water by 2ml
  4. measured absorbance in 550nm

The result is shown in fig 2.

1-3:measurement the effect of remainded E.coli


Sample each medium
Blank mixed liquid (240μℓDNS reagent plus 1760㎕distilled water )


This assay was performed three times for each medium

  1. poured the medium cultured E.coli overnight 1.2 ㎕ into each five microcentritube.
  2. centrifuged them for 5 min at 5,000 rpm
  3. prepared new five microcentritube and move 800㎕ the supernatants into each of them.
  4. measure the OD550 of one tube(use fresh medium as a blank in following assays)
  5. one hour after, we measured OD 550 of other tube
  6. take 80㎕ supernatant and move it into new tube and then heated it for 3 min in boiling water and then cooled it in water.
  7. added 240㎕ DNS reagent and heated it for 3 min in boiling water and then cooled it in water.
  8. two, three, five hours after, we did above operation, taking supernatant, measured OD500, heating and cooling, applying DNS reagent and heating and cooling again.
  9. added all sample tube (containing 320㎕ solution) distilled water by 2ml and measure the absorbance of them in 550nm.

The results of measurement OD550 are shown in fig 3 and of measurement DNS assay are shown in fig 4.




Assay of drosophila's phototaxis in different colors

1. Apparatus

Y maze

Y maze was constructed by a Y joint, cut blue tip, straws and LEDs.Cut blue tip had the function to prevent drosophilas to go backward. Straws and cut blue tip were fitted with the two terminals of Y joint by vinyl tape as figure.LEDs were fitted with the other terminals of the straws by 凹-form parts made of polyethylene board. The angles of Y-form was 120°.

This Y maze is put in the dark-room environment.

Fig.1
Fig.2
Fig.3 : Our dark-room environment

Here is the list of the LEDs which we used in the experiment.

The list of our LEDs
Color Manufacturer No. Name Wavelength
Ultraviolet OptoSupply OSSV5111A 5mm Super Violet LED Peak wavelength = 400 nm
Blue OptoSupply OSUB5161P 5mm Deluxe Blue LED Dominant wavelength = 465~475 nm
Green SHARP GL3GC402B0SC High-luminosity(InGaN) LED Lamp Dominant wavelength = 525 nm
Red OptoSupply OSHR5161P 5mm Deluxe Red LED Dominant wavelength = 620~630 nm
Infrared OptoSupply OSIR5113A 5mm Infrared Emitting Diode Peak wavelength = 940 nm

Pooter

A pooter is very useful tool to move drosophilas. We also used it to move them from rearing bottles to the Y maze.

Our pooter consisted of two parts: tube part and tip part. The tube part was made of vinyl tube and two cutted tips of pipetman. The cutted tips were fitted with the terminals of tube by vinyl tape as mouthpiece and objective end. The tip part was made of two cutted tips of pipetman and a piece of tissue paper. Not to inhale drosophilas into the mouth, the piece of tissue paper was slipped in between the cutted tips.

When we move drosophilasfrom rearing bottles to the Y maze, we fitted the tip part with the tube part and draw some drosophilas into the tip part by mouth. Then closing the orifice of tip part by finger, we removed the tip part from the tube part and put it into the Y maze.

Fig.3
Fig.4


2. Drosophilas

We used the Oregon-RS of Drosophila melanogaster. They were derived from Dr. Fuse's laboratory on 4 August 2011. They were maintained in an incubator at 22℃ on standard cornmeal medium in the ordinary glass bottle with a 12h light phase (12:12 light:dark cycle). Flies were aged 2-4 days after emergence.

3. Method

Firstly, we gathered 5 flies with a pooter. After that, we removed the tip of the pooter and attached the tip to the bottom end of the Y maze. Then we left the flies intact in the dark for three minutes and counted the number of flies in each tube. In this experiment, we switched both the left and right LEDs on for 2 times alternatively. We ran the experiment 4 times using 2 sets of 5 male flies and 2 sets of 5 female flies.

Ymaze experiment method.PNG