Team:Tokyo Tech/Projects/Urea-cooler/method
From 2011.igem.org
(Difference between revisions)
Line 106: | Line 106: | ||
h1, h2, h3, h4, h5, h6 | h1, h2, h3, h4, h5, h6 | ||
{ | { | ||
- | background-color: # | + | background-color: #00508D; |
- | color:# | + | color:#FFFFFF; |
text-align: left; | text-align: left; | ||
} | } | ||
Line 248: | Line 248: | ||
<!-- top box --> | <!-- top box --> | ||
<div class="top"> | <div class="top"> | ||
- | < | + | <OBJECT classid="clsid:D27CDB6E-AE6D-11cf-96B8-444553540000" codebase="http://download.macromedia.com/pub/shockwave/cabs/flash/swflash.cab#version=6,0,0,0" WIDTH="965" HEIGHT="150" id="Header" ALIGN=""> |
+ | <PARAM NAME=movie VALUE="https://static.igem.org/mediawiki/2011/4/4d/Header.swf"> <PARAM NAME=quality VALUE=high> <PARAM NAME=bgcolor VALUE=#FFFFFF> <EMBED src="https://static.igem.org/mediawiki/2011/4/4d/Header.swf" quality=high bgcolor=#FFFFFF WIDTH="965" HEIGHT="150" NAME="Header" ALIGN="" TYPE="application/x-shockwave-flash" PLUGINSPAGE="http://www.macromedia.com/go/getflashplayer"></EMBED> </OBJECT> <br /> | ||
<!-- list of top menu --> | <!-- list of top menu --> | ||
<div id="navigation"> | <div id="navigation"> |
Revision as of 17:34, 4 October 2011
Urea assay method
1. Preparation of samples for urea concentration assay
- A single colony of cells transformed with mock, pTrc-rocF or pTrc-rocF-Arg box was inoculated into 3mL of LB with kanamycin and grown to saturation at 37℃.
- The saturated culture was diluted 50-fold, grown till the log phase (OD600 = 0.5).
- The culture was induced with 1mM IPTG at 37℃ for 1 hour.
- 2mL of culture was centrifuged at 9,000 rmp for 1 minute and the supernatant fluid was used as a sample for urea concentration assay.
2. Urea concentration assay
Urea concentrations of the samples were determined colorimetrically with DIUR-500 -QuantiChrom™ Urea Assay Kit obtained from BioAssay Systems.
Each sample was assayed in triplicate.
- 10 µL of the supernatant fluid from each sample, 10 µL blank(LB),and 10 µL standard (10 mg/dL urea LB) were transferred to wells of clear bottom 96-well plates.
- 200 µL working reagent for coloring reaction from DIUR-500 -QuantiChrom™ Urea Assay Kit was added and the wells were taped lightly to mix.
- Optical density at 450nm was read and urea concentration (mg/dL) of the sample was calculated as
.
ODSAMPLE, ODBLANK and ODSTANDARD are OD450 values of sample, standard and blank, respectively.
Standard curve for coloring reaction in urea assay
To generate standard curve, 0, 0.5, 1.0, 2.5, 7.5, 10mg/dL urea LB were assayed in triplicate in the same way as the samples. Standard curve is shown in Fig.1.
Fig.1 Standard curve for coloring reaction in urea assay