<h2>PcstA+RBS+LuxI+double terminator</h2>
<h2>PcstA+RBS+LuxI+double terminator</h2>
-
This part produces LuxI,an enzyme for creating acyl-homoserine lactones from normal cell metabolites, in the absence of glucose. This part is repressed by glucose.<br>
+
This part produces LuxI,an enzyme for creating acyl-homoserine lactones from normal cell metabolites, in the absence of glucose. This part is repressed by glucose.<br><br>
-
<b>Experiment</b>
+
<b>Experiment</b><br>
-
We grew K569001 (Pcst-RBS-LuxI-terminator) and K131010 (AHL-inducible ColicinE2-GFP) transformed in BL21 E.coli cells in 3mL of LB broth with appropriate antibiotic overnight at 37C and 220rpm. Then we diluted the overnight samples 1:20 and allowed the cells to grow to a predetermined O.D. We combined the two cultures in various ratios and either added or did not add glucose. We allowed these samples to continue growing for 2 hours. After that, we took measurements using a fluorescent microscope. The images shown were the images used to get the data.<br>
+
We grew K569001 (Pcst-RBS-LuxI-terminator) and K131010 (AHL-inducible ColicinE2-GFP) transformed in BL21 E.coli cells in 3mL of LB broth with appropriate antibiotic overnight at 37C and 220rpm. Then we diluted the overnight samples 1:20 and allowed the cells to grow to a predetermined O.D. We combined the two cultures in various ratios and either added or did not add glucose. We allowed these samples to continue growing for 2 hours. After that, we took measurements using a fluorescent microscope. The images shown were the images used to get the data.<br><br>
-
All images were taken with Olympus IX81 automated inverted microscope specially equipped for live cell imaging. The filter set we used is: 470/40x (excitation) and 525/50m (emission) for GFP. Data collection and processing was performed by the SlideBook software.<br>
+
All images were taken with Olympus IX81 automated inverted microscope specially equipped for live cell imaging. The filter set we used is: 470/40x (excitation) and 525/50m (emission) for GFP. Data collection and processing was performed by the SlideBook software.<br><br>
-
These results show a correlation with glucose. The images without glucose show more fluorescence than the images with glucose<br>
+
These results show a correlation with glucose. The images without glucose show more fluorescence than the images with glucose<br><br>
<img src="http://partsregistry.org/wiki/images/c/ca/No_glucose_pictures.png" width="720"><br>