Team:Warsaw/RBSmeasurement

From 2011.igem.org

(Difference between revisions)
Line 17: Line 17:
<div class="note">RBS Measurement</div><br/>
<div class="note">RBS Measurement</div><br/>
<div>
<div>
-
<b>General info</b><p align=justify> We have conducted measurement of various ribosome binding sites included in 2011 spring distribution. Our list of measured parts includes YFP E0030 , GFP SUPERFOLDER , RFP E1010, mOrange E2050, GFP  E0040. DNA of SUPERFOLDER GFP, was included in the distribution as a part of a bigger biobrick. We obtained coding sequence of SUPERFOLDER GFP using PCR method. All measurements were conducted in psb1A2 - a high copy number vector that was used in previous measurement experiments with GFP protein.</p>
+
<b>General info</b><p align=justify> We have conducted measurement of various ribosome binding sites included in 2011 spring distribution. Our list of measured parts includes YFP E0030 , GFP SUPERFOLDER , RFP E1010, mOrange E2050, GFP  E0040. DNA of SUPERFOLDER GFP, was included in the distribution as a part of a bigger biobrick. We obtained coding sequence of SUPERFOLDER GFP using PCR method. All measurements were conducted in psb1A2 - a high copy number vector that was used in previous RBS measurement experiments with GFP protein.</p>
<b>Sample preparation</b><p align="justify">
<b>Sample preparation</b><p align="justify">
To measure fluorescence of samples 3 milliliters of LB with AMP were inoculated with a colony from the plate. Cultures were vigorously shaken in 37° C overnight. The next step was to centrifuge 1,5 milliliters of liquid culture in an 1,5 mltube. Pellet was resuspended in 100 microliters of RF. Finally, prepared samples were placed in the
To measure fluorescence of samples 3 milliliters of LB with AMP were inoculated with a colony from the plate. Cultures were vigorously shaken in 37° C overnight. The next step was to centrifuge 1,5 milliliters of liquid culture in an 1,5 mltube. Pellet was resuspended in 100 microliters of RF. Finally, prepared samples were placed in the

Revision as of 22:32, 21 September 2011

Example Tabs


RBS Measurement

General info

We have conducted measurement of various ribosome binding sites included in 2011 spring distribution. Our list of measured parts includes YFP E0030 , GFP SUPERFOLDER , RFP E1010, mOrange E2050, GFP E0040. DNA of SUPERFOLDER GFP, was included in the distribution as a part of a bigger biobrick. We obtained coding sequence of SUPERFOLDER GFP using PCR method. All measurements were conducted in psb1A2 - a high copy number vector that was used in previous RBS measurement experiments with GFP protein.

Sample preparation

To measure fluorescence of samples 3 milliliters of LB with AMP were inoculated with a colony from the plate. Cultures were vigorously shaken in 37° C overnight. The next step was to centrifuge 1,5 milliliters of liquid culture in an 1,5 mltube. Pellet was resuspended in 100 microliters of RF. Finally, prepared samples were placed in the fluorimeter plate. We used Corning 96 deep well plates with clear UV transparent bottom. Measurements were carried out using Tecan HS2000 pro fluorimeter with bottom read mode and using active gain optimization function. Wavelength values for individual proteins:


GFPYFPRFPmORANGESF-GFP
Excitation [nm]488514554545488
Emission [nm]509530585568508