Team:DTU-Denmark/Ligation protocol

From 2011.igem.org

(Difference between revisions)
Lri (Talk | contribs)
(Created page with "Ligation Protocol Preparation: # Calculate your ligase concentration by estimation of DNA concentration from your restriction gel. # Which vector to use? Material: # prepare li...")
Newer edit →

Revision as of 14:25, 18 September 2011

Ligation Protocol Preparation:

  1. Calculate your ligase concentration by estimation of DNA concentration from your restriction gel.
  2. Which vector to use?

Material:

  1. prepare ligation mix with a total volume of 20 μl
    • 2 μl 10x Buffer
    • parts to be ligated: vector+insert 1:5, DNA conc. less than 50 ng
    • fill up with water
    • 1 μl ligase
    • control (no insert)
  1. Add ligase and keep mix at room temperature for 1h.
    1. To inactivate the ligase place your mix at 65º C for 10 min.
    2. Store on ice.


Before starting on the ligation(s), always run your digestion products on a gel after you’ve performed a clean-up/purification, to verify you actually have been successful in your digestions.

If you want to be very precise with your dna-content calculations, when running the gel you can load the dna-ladder sequentially with a difference of 2-fold dilution.

If your digestions were successful and you are happy with the way your gel looks, you are set to start your ligation calculations. Firstly, make sure you have a dna-ladder illustration indicating the mass of dna at different positions on the gel, then compare the intensity of bands of your digested products with the intensity and position of the bands from the dna-ladder(s).

- The same intensity of bands indicates they must have the same mass of dna.

After you have determined how much dna (mass) you have of each band, you can calculate the dna content on a mole basis by dividing the mass with the length of the fragment.

In general a ligation-mix should look something like this: • Usually a ligation mix should have a total volume of 20 μl, although if you require additional amounts of the same ligation, make a duplicate of the ligation you are trying to make. • The buffer needed is simply called “10x ligation buffer”, and being 10 times concentrated, you need to add 1/10th of the total volume of buffer. Hence if the total volume is 20 μl, you need to add 2 μl of your 10x ligation buffer. • The amount of dna added should conform to the calculations you made from the gel you ran with your digested products. A rule of thumb should be that you take more insert than vector, this way increasing your chances of actually getting a ligation. The ratio of insert to vector should be 5:1 and the total amount of dna should not exceed 50 ng. • The two remaining items to be added into your mix will be ddH2O and Ligase. The amount of Ligase enzyme to be added is only 1 μl, so you know how much dna (insert+vector), Ligase and the buffer to add; the rest of the volume (→ 20 μl) should be accounted for with ddH2O. • Remember though that Ligase should only be added in the end, because once added into your mix its going to get to work and you don’t want it playing around with your dna before you have added everything else. Another important thing to remember is that the Ligase enzyme cannot be taken from the freezer to your lab-bench; you have to instead add your Ligase into your mix by working at the freezer. • Controls are always important and good indications if things are working the way they should be, so a good control with ligations would be to have a negative control, that being just vector with no insert, the rest of the recipe being the same. This should hopefully give you no colonies as it would indicate your digested vector is in fact digested and didn’t re-ligate. If there are colonies on your negative control plate, it will give you a good indication of the background noise on your actual ligation plates.