Team:Northwestern/Notebook/Protocols/Plates

From 2011.igem.org

(Difference between revisions)
(Created page with "__NOTOC__ {{:Team:Northwestern/Templates/trial}} <DIV style="font-size:20px"> Making LB Plates </DIV> ---------------------- '''Materials''' For 1 L of Media: *10g Tryptone ...")
Line 22: Line 22:
'''Directions'''
'''Directions'''
-
#Pre-heat a water bath to 55C (optional). Add dry materials and water to a flask sufficiently large to minimize boil-over (2L flask for 1L of media)
+
#Pre-heat a water bath to 55C (optional). Add dry materials and water to a flask sufficiently large to minimize boil-over, such as using a 2L flask for 1L of media
#Add a magnetic stir bar and stir the media.
#Add a magnetic stir bar and stir the media.
-
#Cover the top of the flask LOOSELY with aluminum foil.
+
#Cover the top of the flask loosely with aluminum foil.
#Autoclave the media for 30 minutes on a fluid cycle.
#Autoclave the media for 30 minutes on a fluid cycle.
-
#Remove media to 55 deg. H2O bath or room temp to cool (if not using water bath, just make sure the timing is right so that you pour your plates before it starts to solidify. Once media has cooled to ~55 deg. C, add antibiotics, if required.
+
#Remove media to 55C water bath or room temp to cool (if not using water bath, just make sure the timing is right so that you pour your plates before it starts to solidify). Once media has cooled sufficiently to around 55C, add antibiotics if required.
-
#Obtain 2 sleeves of empty plates. 1 L of media will make about 40 plates.
+
#Obtain 2 sleeves of empty plates. 1 L of media will make about 40 plates. Using sterile technique, pour the media into the plates.  
-
#Using sterile technique, pour the media into the plates.  
+
#*Cover the base of the plate, and then just a bit more after that.
#*Cover the base of the plate, and then just a bit more after that.
-
#*Recap each plate upon pouring. If there are lots of bubbles in your plates (i.e., more than one or two on the edge), you can flame the plate using the small bunsen burner to eliminate bubbles. (See a demo on this).  Another way to remove the fine bubbles that may be in your flask before pouring is to mist the inside of the flask with a 75% ethanol spray bottle.
+
#*Recap each plate upon pouring. If there are lots of bubbles in your plates (i.e., more than one or two on the edge), you can flame the plate using the small bunsen burner to eliminate bubbles. Another way to remove the fine bubbles that may be in your flask before pouring is to mist the inside of the flask with a 75% ethanol spray bottle.  
-
#Leave plates to dry and cool for a while (overnight even).
+
-
#*It is a good idea to label the stack of plates to indicate antibiotic.
+
-
#Store the plates in their original bags - upside down, so that the gel is hanging downwards (this keeps condensation off the gel).
+
#Label the plates following these rules:
#Label the plates following these rules:
#*Red stripe - AMP
#*Red stripe - AMP
#*Blue stripe - KAN
#*Blue stripe - KAN
#*Green stripe - CHLOR
#*Green stripe - CHLOR
-
#Store the labeled bags of plates in the cold room.
+
#Leave plates to dry and cool for a while (overnight even). Store the plates in their original bags - upside down, so that the gel is hanging downwards (this keeps condensation off the gel) in the cold room
Adapted from [http://openwetware.org/wiki/Endy:Pouring_plates OpenWetWare]
Adapted from [http://openwetware.org/wiki/Endy:Pouring_plates OpenWetWare]

Revision as of 21:20, 12 August 2011

RETURN TO IGEM 2010


Making LB Plates



Materials

For 1 L of Media:

  • 10g Tryptone
  • 5g Yeast Extract
  • 10g NaCl
  • 10 g of Agar (for 1% Agar plates (w/v))
  • 1 L ddH2O
  • Sterile antibiotic stock solution (if required)


Directions

  1. Pre-heat a water bath to 55C (optional). Add dry materials and water to a flask sufficiently large to minimize boil-over, such as using a 2L flask for 1L of media
  2. Add a magnetic stir bar and stir the media.
  3. Cover the top of the flask loosely with aluminum foil.
  4. Autoclave the media for 30 minutes on a fluid cycle.
  5. Remove media to 55C water bath or room temp to cool (if not using water bath, just make sure the timing is right so that you pour your plates before it starts to solidify). Once media has cooled sufficiently to around 55C, add antibiotics if required.
  6. Obtain 2 sleeves of empty plates. 1 L of media will make about 40 plates. Using sterile technique, pour the media into the plates.
    • Cover the base of the plate, and then just a bit more after that.
    • Recap each plate upon pouring. If there are lots of bubbles in your plates (i.e., more than one or two on the edge), you can flame the plate using the small bunsen burner to eliminate bubbles. Another way to remove the fine bubbles that may be in your flask before pouring is to mist the inside of the flask with a 75% ethanol spray bottle.
  7. Label the plates following these rules:
    • Red stripe - AMP
    • Blue stripe - KAN
    • Green stripe - CHLOR
  8. Leave plates to dry and cool for a while (overnight even). Store the plates in their original bags - upside down, so that the gel is hanging downwards (this keeps condensation off the gel) in the cold room


Adapted from [http://openwetware.org/wiki/Endy:Pouring_plates OpenWetWare]