Team:Tokyo Tech/Projects/Urea-cooler/method
From 2011.igem.org
(Difference between revisions)
Line 332: | Line 332: | ||
<li>200 µL working reagent for coloring reaction from DIUR-500 -QuantiChrom™ Urea Assay Kit was added and the wells were taped lightly to mix.</li> | <li>200 µL working reagent for coloring reaction from DIUR-500 -QuantiChrom™ Urea Assay Kit was added and the wells were taped lightly to mix.</li> | ||
<li>Optical density at 450nm was read and urea concentration (mg/dL) of the sample was calculated as<br /> | <li>Optical density at 450nm was read and urea concentration (mg/dL) of the sample was calculated as<br /> | ||
- | <img src="https://static.igem.org/mediawiki/2011/5/55/Kit_equation.png" alt="equation" />. </li> | + | <img src="https://static.igem.org/mediawiki/2011/5/55/Kit_equation.png" alt="equation" />.<br /> |
+ | ODSAMPLE, ODBLANK and ODSTANDARD are OD450 values of sample, standard and blank, respectively. </li> | ||
</ol> | </ol> | ||
</p> | </p> | ||
+ | |||
+ | |||
<!-- ############ End of main contents ############ --> | <!-- ############ End of main contents ############ --> |
Revision as of 11:27, 4 October 2011
Urea assay method
1. Preparation of samples for urea concentration assay
- A single colony of cells transformed with mock, pTrc-rocF or pTrc-rocF-Arg box was inoculated into 3mL of LB with kanamycin and grown to saturation at 37℃.
- The saturated culture was diluted 50-fold, grown till the log phase (OD600 = 0.5).
- The culture was induced with 1mM IPTG at 37℃ for 1 hour.
- 2mL of culture was centrifuged at 9,000 rmp for 1 minute and the supernatant fluid was used as a sample for urea concentration assay.
2.Urea concentration assay
Urea concentrations of the samples were determined colorimetrically with DIUR-500 -QuantiChrom™ Urea Assay Kit obtained from BioAssay Systems.
Each sample was assayed in triplicate.
- 10 µL of the supernatant fluid from each sample, 10 µL blank(LB),and 10 µL standard (10 mg/dL urea LB) were transferred to wells of clear bottom 96-well plates.
- 200 µL working reagent for coloring reaction from DIUR-500 -QuantiChrom™ Urea Assay Kit was added and the wells were taped lightly to mix.
- Optical density at 450nm was read and urea concentration (mg/dL) of the sample was calculated as
.
ODSAMPLE, ODBLANK and ODSTANDARD are OD450 values of sample, standard and blank, respectively.