Team:Wisconsin-Madison/ethanol
From 2011.igem.org
Line 226: | Line 226: | ||
The primary source of results thus far has been a plate reader. This is a device which can record the optical density (OD – a measure of cell concentration) as well as the fluorescence of up to 96 cultures at once. Ideally, we hope to produce such a robust fluorescent response as to not need the plate reader for qualitative assessments. | The primary source of results thus far has been a plate reader. This is a device which can record the optical density (OD – a measure of cell concentration) as well as the fluorescence of up to 96 cultures at once. Ideally, we hope to produce such a robust fluorescent response as to not need the plate reader for qualitative assessments. | ||
<p><br> | <p><br> | ||
- | This graph shows the fluorescent response of cell cultures containing two plasmids: pBAD33bb: exaDE and PexaA: TagRFP in pSB1A2 (pEtRv2.1). The fluorescence of the system at varying ethanol concentrations was normalized to the optical density of their respective cell culture. The cells’ fluorescence was measured over a range of ethanol concentrations from 0 | + | This graph shows the fluorescent response of cell cultures containing two plasmids: pBAD33bb: exaDE and PexaA: TagRFP in pSB1A2 (pEtRv2.1). The fluorescence of the system at varying ethanol concentrations was normalized to the optical density of their respective cell culture. The cells’ fluorescence was measured over a range of ethanol concentrations from 0-5% EtOH. This ethanol sensing system is “turned on” or induced in the presence of arabinose by the PBAD promoter. The blue data points on the graph represent the fluorescence of cell cultures without any arabinose and therefore the ethanol sensor is uninduced; the red data points represent the fluorescent response of the induced system in the presence of 0.2% arabinose. |
<p><br> | <p><br> | ||
<img src="https://static.igem.org/mediawiki/2011/0/00/Pets_2.1_graph.jpg" align="left" width="500"> | <img src="https://static.igem.org/mediawiki/2011/0/00/Pets_2.1_graph.jpg" align="left" width="500"> |
Revision as of 23:02, 28 September 2011
Project >>
Overview,
Ethanol Sensor,
Alkane Sensor,
Microcompartment
Ethanol Sensor
The primary source of results thus far has been a plate reader. This is a device which can record the optical density (OD – a measure of cell concentration) as well as the fluorescence of up to 96 cultures at once. Ideally, we hope to produce such a robust fluorescent response as to not need the plate reader for qualitative assessments.
|