Team:Virginia Tech/Project
From 2011.igem.org
(7 intermediate revisions not shown) | |||
Line 1: | Line 1: | ||
<!-- Image at the top of each page --> | <!-- Image at the top of each page --> | ||
- | [[Image:Virginia_Tech_logo.png| | + | <center> |
+ | [[Image:division.png|225 px|bottom]] | ||
+ | [[Image:Virginia_Tech_logo.png|250px]] | ||
+ | [[Image:diatoms.png|210 px|bottom]] | ||
+ | </center> | ||
<!--- Navigation Box ---> | <!--- Navigation Box ---> | ||
- | |||
- | |||
<!-- baltimore's box style: "background-color:#7998AD;" cellpadding="1" cellspacing="1" border="0" bordercolor="#fff" width="924px" align="center" --> | <!-- baltimore's box style: "background-color:#7998AD;" cellpadding="1" cellspacing="1" border="0" bordercolor="#fff" width="924px" align="center" --> | ||
+ | {| style=" background-color:#800000;" cellpadding="1" cellspacing="5" border="0" width="90%" align="center" | ||
+ | |||
- | + | !align="center"|[[Team:Virginia_Tech|<span style="color:orange;">Home</span>]] | |
- | !align="center"|[[Team:Virginia_Tech|Home]] | + | !align="center"|[[Team:Virginia_Tech/Team|<span style="color:orange;">Team</span>]] |
- | !align="center"|[[Team:Virginia_Tech/Team|Team]] | + | !align="center"|[https://igem.org/Team.cgi?year=2011&team_name=Virginia_Tech <span style="color:orange;">Official Team Profile</span>] |
- | !align="center"|[https://igem.org/Team.cgi?year=2011&team_name=Virginia_Tech Official Team Profile] | + | !align="center"|[[Team:Virginia_Tech/Project|<span style="color:orange;">Project</span>]] |
- | !align="center"|[[Team:Virginia_Tech/Project|Project]] | + | !align="center"|[[Team:Virginia_Tech/Parts|<span style="color:orange;">Parts Submitted to the Registry</span>]] |
- | !align="center"|[[Team:Virginia_Tech/Parts|Parts Submitted to the Registry]] | + | !align="center"|[[Team:Virginia_Tech/Notebook|<span style="color:orange;">Notebook</span>]] |
- | !align="center"|[[Team:Virginia_Tech/Notebook|Notebook]] | + | !align="center"|[[Team:Virginia_Tech/Safety|<span style="color:orange;">Safety</span>]] |
- | !align="center"|[[Team:Virginia_Tech/Safety|Safety]] | + | !align="center"|[[Team:Virginia_Tech/Attributions|<span style="color:orange;">Attributions</span>]] |
- | !align="center"|[[Team:Virginia_Tech/Attributions|Attributions]] | + | |
|} | |} | ||
Line 23: | Line 26: | ||
__NOTOC__ | __NOTOC__ | ||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
<!-- to use wiki featuers, put <h2> </h2> etc around headings, makes little box at top of page to link to sections (kind of obnoxious) --> | <!-- to use wiki featuers, put <h2> </h2> etc around headings, makes little box at top of page to link to sections (kind of obnoxious) --> | ||
==Project Overview:== | ==Project Overview:== | ||
- | <p>Since the isolation of GFP in 1962, fluorescent proteins have become a ubiquitous tool for studying cellular processes and have | + | <p>Since the isolation of GFP in 1962, fluorescent proteins have become a ubiquitous tool for studying cellular processes and have found applications in synthetic biology - for example serving as a reporter of the performance of the canonical repressilator. To be better suited to the increasing precision of biological experimentation and the increasing sophistication of synthetic networks, however, these proteins will need to be more quantitatively characterized and used. To this end, the 2011 VT iGEM team is interested in finding and optimizing good fluorescent reporters which mature and degrade quickly, and which fluoresce brightly. This involves establishing a framework for modeling and characterizing fluorescent proteins, and then using this framework to find fast-maturing proteins and degradation tags that help destabilize and degrade them. We hope that this work will lay a good foundation for a more quantitative use of fluorescent reporters in the future.</p> |
<p>To tackle this problem, we have split our team into three specialized groups focusing on the Design, Fabrication, and Characterization of our fluorescent protein constructs. This transdisciplinary approach allows us to work more quickly and achieve more ambitious goals</p> | <p>To tackle this problem, we have split our team into three specialized groups focusing on the Design, Fabrication, and Characterization of our fluorescent protein constructs. This transdisciplinary approach allows us to work more quickly and achieve more ambitious goals</p> | ||
===Design=== | ===Design=== | ||
- | <p>The Design Team designs biological constructs and makes predictions about their performance using the software tool GenoCAD. As a Computer Assisted Design (CAD) tool, GenoCAD has a repository of biological parts, grammatical rules that help users put them together, and an attribute-grammar-based structure that helps users make predictions about how their assemblies will perform before they are made in a lab. The Design Team works with all of these aspects of GenoCAD - searching for promising fluorescent reporters, promoters, and degradation tags to add to the repository, writing grammatical rules specific to this project, and using attributes to model how they expect our constructs to behave. This software has been very useful to our project and has made it easy for the Design Team to quickly design many constructs and pass information about them to the Fabrication Team. </p> | + | <i> Design Team Members: Mark, Daniel</i> |
+ | <p>The Design Team designs biological constructs and makes predictions about their performance using the software tool GenoCAD. As a Computer Assisted Design (CAD) tool, GenoCAD has a repository of biological parts, grammatical rules that help users put them together, and an attribute-grammar-based structure that helps users make predictions about how their assemblies will perform before they are made in a lab. The Design Team works with all of these aspects of GenoCAD - searching for promising fluorescent reporters, promoters, and degradation tags to add to the repository, writing grammatical rules specific to this project that govern how parts can be put together, and using attributes to model how they expect our constructs to behave. This software has been very useful to our project and has made it easy for the Design Team to quickly design many constructs and pass information about them to the Fabrication Team. </p> | ||
+ | |||
===Fabrication=== | ===Fabrication=== | ||
- | <p>The fabrication team experimentally creates the constructs designed in silico. Through traditional cloning or BioBrick assembly, they assemble the various parts comprised in a specific design. The created recombinant molecules are transformed into specific hosts: ''Escherichia coli'' or ''Saccharomyces cerevisiae''. The constructs generated are screened and sequenced to confirm their successful assembly. The positive clones are passed to the characterization team.</p> | + | <i> Fabrication Team Members: Mandy, Loran, Hayley, Swetha</i> |
+ | <p>The fabrication team experimentally creates the constructs designed <i>in silico</i>. Through traditional cloning or BioBrick assembly, they assemble the various parts comprised in a specific design. The created recombinant molecules are transformed into specific hosts: ''Escherichia coli'' or ''Saccharomyces cerevisiae''. The constructs generated are screened and sequenced to confirm their successful assembly. The positive clones are passed to the characterization team.</p> | ||
===Characterization=== | ===Characterization=== | ||
+ | <i> Fabrication Team Members: Judith, Brittany, Meghan, Adam</i> | ||
<p>The Characterization Team collects and analyzes data on our constructs after they have been designed and fabricated. They specifically want to determine how quickly the different fluorescent protein constructs mature and degrade. To collect data, they are using an automated microscope platform that includes a microfluidic system for trapping cells, and switching the available nutrients to them. All of the hardware is adaptively controlled by the software GenoSIGHT. This arrangement allows them to precisely control when cells are exposed to a stimulus, and automates the collection of fluorescence data. After data is collected it is compared to a mathematical model of expected maturation and degradation processes. Parameter estimation is then used to give us quantitative descriptions of our constructs. This information is used to compare different constructs, and it is passed back to the Design Team. The Design Team then compares these results to their expectations, adjusts their models accordingly, and generates new designs as necessary, beginning the cycle all over again. </p> | <p>The Characterization Team collects and analyzes data on our constructs after they have been designed and fabricated. They specifically want to determine how quickly the different fluorescent protein constructs mature and degrade. To collect data, they are using an automated microscope platform that includes a microfluidic system for trapping cells, and switching the available nutrients to them. All of the hardware is adaptively controlled by the software GenoSIGHT. This arrangement allows them to precisely control when cells are exposed to a stimulus, and automates the collection of fluorescence data. After data is collected it is compared to a mathematical model of expected maturation and degradation processes. Parameter estimation is then used to give us quantitative descriptions of our constructs. This information is used to compare different constructs, and it is passed back to the Design Team. The Design Team then compares these results to their expectations, adjusts their models accordingly, and generates new designs as necessary, beginning the cycle all over again. </p> |
Latest revision as of 03:36, 29 September 2011
Home | Team | Official Team Profile | Project | Parts Submitted to the Registry | Notebook | Safety | Attributions |
---|