Team:Cambridge/Protocols/Gel Extraction of DNA

From 2011.igem.org

(Difference between revisions)
(Practice)
(Practice)
Line 25: Line 25:
;Step 1
;Step 1
-
:*Add 3 volumes of buffer QG to 1 volume of gel. E.g.add 300 μl of Buffer QG to each slice of gel (volume of the slice is 100 μl, and weighs approximately 100 mg).
+
:*<span style="font-weight:normal;"> Add 3 volumes of buffer QG to 1 volume of gel. E.g.add 300 &mu;l of Buffer QG to each slice of gel (volume of the slice is 100 &mu;l, and weighs approximately 100 mg). </span>
;Step 2
;Step 2
-
:*Incubate at 50°C for 10 min (or until fully dissolved). To aid solvation, mix by vortexing the tube every 2–3 min during the incubation.  
+
:*<span style="font-weight:normal;"> Incubate at 50°C for 10 min (or until fully dissolved). To aid solvation, mix by vortexing the tube every 2–3 min during the incubation. </span>
;Step 3
;Step 3
-
:*After the gel slice has dissolved fully, check that the colour of the mixture is yellow (similar to Buffer QG without dissolved agarose).  
+
:*<span style="font-weight:normal;"> After the gel slice has dissolved fully, check that the colour of the mixture is yellow (similar to Buffer QG without dissolved agarose). </span>
;Step 4
;Step 4
-
:*Add 1 gel volume of isopropanol to the sample and mix.
+
:*<span style="font-weight:normal;"> Add 1 gel volume of isopropanol to the sample and mix. </span>
;Step 5
;Step 5
-
:*Place a QIAquick spin column in a provided 2 ml collection tube.
+
:*<span style="font-weight:normal;"> Place a QIAquick spin column in a provided 2 ml collection tube. </span>
;Step 6
;Step 6
-
:*apply each sample of DNA fragment to a QIAquick column, and centrifuge for 1 min at 13000 rpm.
+
:*<span style="font-weight:normal;"> Apply each sample of DNA fragment to a QIAquick column, and centrifuge for 1 min at 13000 rpm. </span>
;Step 7
;Step 7
-
:*Discard flow-through and place QIAquick column back in the same collection tube.
+
:*<span style="font-weight:normal;"> Discard flow-through and place QIAquick column back in the same collection tube. </span>
;Step 8 (Optional)
;Step 8 (Optional)
-
:*Add 0.5 ml of Buffer QG to QIAquick column and centrifuge for 1 min.
+
:*<span style="font-weight:normal;"> Add 0.5 ml of Buffer QG to QIAquick column and centrifuge for 1 min. </span>
-
''This step will remove all traces of agarose. It is only required when the DNA will subsequently be used for direct sequencing, in vitro transcription or microinjection.''
+
'''''This step will remove all traces of agarose. It is only required when the DNA will subsequently be used for direct sequencing, in vitro transcription or microinjection.'''''
;Step 9
;Step 9
-
:To wash, add 0.75 ml of Buffer PE to QIAquick column and centrifuge for 1 min. ''(If this step is omitted, follow [[Team:Cambridge/Protocols/DNA Precipitation |Rescue Precipitation of DNA]])''
+
:<span style="font-weight:normal;">To wash, add 0.75 ml of Buffer PE to QIAquick column and centrifuge for 1 min.</span> '''''(If this step is omitted, follow [[Team:Cambridge/Protocols/DNA Precipitation |Rescue Precipitation of DNA]])'''''
;Step 10
;Step 10
-
:Discard the flow-through and centrifuge the QIAquick column for an additional 1 min at ≥ 10,000 x g (~13,000 rpm).
+
:<span style="font-weight:normal;">Discard the flow-through and centrifuge the QIAquick column for an additional 1 min at ≥ 10,000 x g (~13,000 rpm).</span>
'''IMPORTANT:''' '''''Residual ethanol from Buffer PE will not be completely removed unless the flow-through is discarded before this additional centrifugation.'''''
'''IMPORTANT:''' '''''Residual ethanol from Buffer PE will not be completely removed unless the flow-through is discarded before this additional centrifugation.'''''
;Step 11
;Step 11
-
:Place QIAquick column into a clean 1.5 ml microcentrifuge tube.
+
:<span style="font-weight:normal;"> Place QIAquick column into a clean 1.5 ml microcentrifuge tube. </span>
;Step 12
;Step 12
-
:To elute DNA, add 50 &mu;l of Buffer EB (10 mM Tris·Cl, pH 8.5) or H<sub>2</sub>O to the center of the QIAquick membrane and centrifuge the column for 1 min at 13000rpm. Alternatively, for increased DNA concentration, add 30 &mu;l elution buffer to the center of the QIAquick membrane, let the column stand for 1 min, and then centrifuge for 1 min.
+
:<span style="font-weight:normal;"> To elute DNA, add 50 &mu;l of Buffer EB (10 mM Tris·Cl, pH 8.5) or H<sub>2</sub>O to the center of the QIAquick membrane and centrifuge the column for 1 min at 13000rpm. Alternatively, for increased DNA concentration, add 30 &mu;l elution buffer to the center of the QIAquick membrane, let the column stand for 1 min, and then centrifuge for 1 min. </span>
'''IMPORTANT:''' '''''Ensure that the elution buffer is dispensed directly onto the QIAquick membrane for complete elution of bound DNA. The average eluate volume is 48 &mu;l from 50 &mu;l elution buffer volume, and 28 &mu;l from 30 &mu;l. Elution efficiency is dependent on pH. The maximum elution efficiency is achieved between pH 7.0 and 8.5. When using water, make sure that the pH value is within this range, and store DNA at –20°C as DNA may degrade in the absence of a buffering agent. The purified DNA can also be eluted in TE (10 mM Tris·Cl, 1 mM EDTA, pH 8.0), but the EDTA may inhibit subsequent enzymatic reactions.''''
'''IMPORTANT:''' '''''Ensure that the elution buffer is dispensed directly onto the QIAquick membrane for complete elution of bound DNA. The average eluate volume is 48 &mu;l from 50 &mu;l elution buffer volume, and 28 &mu;l from 30 &mu;l. Elution efficiency is dependent on pH. The maximum elution efficiency is achieved between pH 7.0 and 8.5. When using water, make sure that the pH value is within this range, and store DNA at –20°C as DNA may degrade in the absence of a buffering agent. The purified DNA can also be eluted in TE (10 mM Tris·Cl, 1 mM EDTA, pH 8.0), but the EDTA may inhibit subsequent enzymatic reactions.''''

Revision as of 13:37, 20 July 2011

Loading...
OVERVIEW
home


Gel Extraction of DNA (Spin Column Extraction)

A technique used to isolate a desired fragment of intact DNA from an agarose gel following agarose gel electrophoresis

Theory

Gel extraction or gel isolation is a technique used to isolate a desired fragment of intact DNA from an agarose gel following agarose gel electrophoresis. After extraction, fragments of interest can be mixed, precipitated, and enzymatically ligated together in several simple steps. This process is the basis for rudimentary genetic engineering.


After DNA samples are run on an agarose gel, extraction involves four basic steps:

  1. identifying the fragments of interest
  2. isolating the corresponding bands
  3. isolating the DNA from those bands
  4. removing the accompanying salts and stain.


Practice

Used QIAgen quick gel extraction kit, the protocol is adapted from the QIAgen gel extraction protocol [http://openwetware.org/images/5/5e/QIAquick_Gel_Extraction_Kit_Protocol.pdf QIAquick Gel Extraction Kit Protocol].

The gel is exposed to blue-light to illuminate the DNA fragments(stained by SYBR safe dye). The desired DNA band is identified and physically removed with a rectangular tipped pipette. The removed slice of gel contains the desired DNA.

Step 1
  • Add 3 volumes of buffer QG to 1 volume of gel. E.g.add 300 μl of Buffer QG to each slice of gel (volume of the slice is 100 μl, and weighs approximately 100 mg).
Step 2
  • Incubate at 50°C for 10 min (or until fully dissolved). To aid solvation, mix by vortexing the tube every 2–3 min during the incubation.
Step 3
  • After the gel slice has dissolved fully, check that the colour of the mixture is yellow (similar to Buffer QG without dissolved agarose).
Step 4
  • Add 1 gel volume of isopropanol to the sample and mix.
Step 5
  • Place a QIAquick spin column in a provided 2 ml collection tube.
Step 6
  • Apply each sample of DNA fragment to a QIAquick column, and centrifuge for 1 min at 13000 rpm.
Step 7
  • Discard flow-through and place QIAquick column back in the same collection tube.
Step 8 (Optional)
  • Add 0.5 ml of Buffer QG to QIAquick column and centrifuge for 1 min.

This step will remove all traces of agarose. It is only required when the DNA will subsequently be used for direct sequencing, in vitro transcription or microinjection.

Step 9
To wash, add 0.75 ml of Buffer PE to QIAquick column and centrifuge for 1 min. (If this step is omitted, follow Rescue Precipitation of DNA)
Step 10
Discard the flow-through and centrifuge the QIAquick column for an additional 1 min at ≥ 10,000 x g (~13,000 rpm).

IMPORTANT: Residual ethanol from Buffer PE will not be completely removed unless the flow-through is discarded before this additional centrifugation.

Step 11
Place QIAquick column into a clean 1.5 ml microcentrifuge tube.
Step 12
To elute DNA, add 50 μl of Buffer EB (10 mM Tris·Cl, pH 8.5) or H2O to the center of the QIAquick membrane and centrifuge the column for 1 min at 13000rpm. Alternatively, for increased DNA concentration, add 30 μl elution buffer to the center of the QIAquick membrane, let the column stand for 1 min, and then centrifuge for 1 min.

IMPORTANT: Ensure that the elution buffer is dispensed directly onto the QIAquick membrane for complete elution of bound DNA. The average eluate volume is 48 μl from 50 μl elution buffer volume, and 28 μl from 30 μl. Elution efficiency is dependent on pH. The maximum elution efficiency is achieved between pH 7.0 and 8.5. When using water, make sure that the pH value is within this range, and store DNA at –20°C as DNA may degrade in the absence of a buffering agent. The purified DNA can also be eluted in TE (10 mM Tris·Cl, 1 mM EDTA, pH 8.0), but the EDTA may inhibit subsequent enzymatic reactions.'

Safety

The safety implication of the procedure.