Team:Wageningen UR/Project/DevicesSetup
From 2011.igem.org
RubenvanHeck (Talk | contribs) m (→Custom fluidic device designed by Team Wageningen UR to measure oscillations) |
(→Custom fluidic device designed by Team Wageningen UR to measure oscillations) |
||
(12 intermediate revisions not shown) | |||
Line 24: | Line 24: | ||
=== Choosing the ideal bacterial growing platform === | === Choosing the ideal bacterial growing platform === | ||
- | In order to physically constrain the bacteria, Hasty used a trapping chamber as depicted in Figure 1. The chamber he used was 100 by 100 by 1 micron. This caused the cells to grow in a monolayer. AHL and excess cells were flushed away through the main channel | + | In order to physically constrain the bacteria, Hasty used a trapping chamber as depicted in Figure 1. The chamber he used was 100 by 100 by 1 micron. This caused the cells to grow in a monolayer. AHL and excess cells were flushed away through the main channel [1]. |
[[File:Hasty_device_WUR.png|200px|center]] | [[File:Hasty_device_WUR.png|200px|center]] | ||
- | + | [[File:Legend_device_WUR.png|140px|center]] | |
'''Fig.1''' The micro-sieve seemed promising for creating a monolayer of cells. The cells could be drawn toward the sieve by applying an under pressure (for example with a syringe). Since the Top10 ''E.coli'' strain used for our transformations does not form biofilms, additional cells would be flushed away once all the pores of the micro-sieve are blocked. However, the flow over this monolayer is in a different dimensional plane (compare figure 1 & 2). The direction of the flow over the micro-sieve can be seen in figure 2. | '''Fig.1''' The micro-sieve seemed promising for creating a monolayer of cells. The cells could be drawn toward the sieve by applying an under pressure (for example with a syringe). Since the Top10 ''E.coli'' strain used for our transformations does not form biofilms, additional cells would be flushed away once all the pores of the micro-sieve are blocked. However, the flow over this monolayer is in a different dimensional plane (compare figure 1 & 2). The direction of the flow over the micro-sieve can be seen in figure 2. | ||
Line 34: | Line 34: | ||
'''Fig.2:''' This setup imposes the problem that the diffusion of AHL is much slower than the flow rate over the sieve. Therefore, the AHL produced will always be flushed away before a uniform concentration can be established over the whole cell culture, thus preventing any synchronized behavior to arise. The use of a microsieve in the course of our iGEM project was therefore discarded. | '''Fig.2:''' This setup imposes the problem that the diffusion of AHL is much slower than the flow rate over the sieve. Therefore, the AHL produced will always be flushed away before a uniform concentration can be established over the whole cell culture, thus preventing any synchronized behavior to arise. The use of a microsieve in the course of our iGEM project was therefore discarded. | ||
- | The problem described above does not arise when using the microdish. In the 40 micron deep wells the cells can be trapped and AHL will have a better chance to establish a uniform concentration throughout the well. This will create a higher chance of synchronized oscillatory behavior of the cells growing in a well. Special care has to be taken with the velocities of the fluid flowing over the wells: | + | The problem described above does not arise when using the microdish. In the 40 micron deep wells the cells can be trapped and AHL will have a better chance to establish a uniform concentration throughout the well. This will create a higher chance of synchronized oscillatory behavior of the cells growing in a well. Special care has to be taken with the velocities of the fluid flowing over the wells: if the flow rate is too high, the cells will be spilled out of the wells. This behavior was observed under the microscope. |
[[File:Micro-dish1_device_WUR.png|290px]] [[File:Flushingoutofwells_WUR.gif|300px|right]] | [[File:Micro-dish1_device_WUR.png|290px]] [[File:Flushingoutofwells_WUR.gif|300px|right]] | ||
- | '''Fig.3''' | + | '''Fig.3 (Top)''' |
+ | |||
+ | '''Fig.4 (Right)''' | ||
Line 45: | Line 47: | ||
- | Because it is not necessary for our system to have a flow going over the wells we eventually only used bottom flow, as depicted in figure 5 | + | Because it is not necessary for our system to have a flow going over the wells we eventually only used bottom flow, as depicted in figure 5. Our resulting setup enabled us to bottom feed our bacteria, this is depicted in figure 6. This allowed the measurements to be taken continuously for various hours, as nutrients could diffuse through the bottom of the wells. Measurements were taken with the use of our LEGO robot (see [https://2011.igem.org/Team:Wageningen_UR/Project/DevicesFunFacts fun facts]). |
- | + | ||
- | + | ||
- | + | ||
- | + | ||
- | + | ||
- | + | ||
- | + | ||
- | + | ||
+ | [[File:Micro-dish2_device_WUR.png|270px]] [[File:Bottom_feed_WUR.png|470px|right]] | ||
+ | '''Fig.5 (Top)''' ''Using microdish with bottom flow'' | ||
+ | '''Fig.6 (Right)''' ''Applying bottom feeding to keep the cells in the wells alive'' | ||
Line 78: | Line 75: | ||
- | [[Team:Wageningen_UR/Project/DevicesSetup# | + | [[Team:Wageningen_UR/Project/DevicesSetup#Custom fluidic device designed by Team Wageningen UR to measure oscillations| back to top]] |
Line 84: | Line 81: | ||
- | During our plate reader experiments we observed oscillatory behavior of transformed ''E.coli'' containing the [[Team:Wageningen_UR/Project/CompleteProject1Description# | + | During our plate reader experiments we observed oscillatory behavior of transformed ''E.coli'' containing the [[Team:Wageningen_UR/Project/CompleteProject1Description#3._Designs| streamlined construct]]. This suggested oscillations could occur even without applying any flow over the wells. Letting the [[Team:Wageningen_UR/Project/ModelingProj1#Writing_a_modeling_tool_in_Matlab| modeling tool]] iterate over a range of cell densities while keeping the flow rate constant at 0 confirmed that [[Team:Wageningen_UR/Project/ModelingProj1#Preliminary_conclusions_for_our_system| oscillations could occur]] at high cell densities. Therefore the measurements were taken without applying any flow. |
[[File:Measuring_GFP_WUR.jpg|500px|center]] | [[File:Measuring_GFP_WUR.jpg|500px|center]] | ||
- | + | ||
For the experiments, an overnight culture of the cells containing our construct was spun down and resuspended in PBS. The resuspended culture was inoculated in the device and left in the chamber to settle down for a while. Since the bacteria were bottom fed with LB as seen in the setup section in [[Team:Wageningen_UR/Project/DevicesSetup#Controlling_cell_growth| figure 6]], only the bacteria which settled down in the wells survived, while the bacteria in PBS starved to death. This is shown in the short video below. The pictures were taken every ten minutes. | For the experiments, an overnight culture of the cells containing our construct was spun down and resuspended in PBS. The resuspended culture was inoculated in the device and left in the chamber to settle down for a while. Since the bacteria were bottom fed with LB as seen in the setup section in [[Team:Wageningen_UR/Project/DevicesSetup#Controlling_cell_growth| figure 6]], only the bacteria which settled down in the wells survived, while the bacteria in PBS starved to death. This is shown in the short video below. The pictures were taken every ten minutes. | ||
Line 99: | Line 96: | ||
[[File:ptetGFP_PBS.jpg|350px]] [[File:ptetGFP_PBSremoved.jpg|350px|right]] | [[File:ptetGFP_PBS.jpg|350px]] [[File:ptetGFP_PBSremoved.jpg|350px|right]] | ||
- | |||
- | |||
- | |||
+ | '''Fig.9''' ''Microdish with ptetGFP inoculum in PBS (left) and cells in wells after removal of the PBS (right)'' | ||
+ | |||
+ | |||
+ | For the experiment depicted above, the PBS was removed before all the cells died. The procedure varied depending on how well the bacteria settled down in the wells. They were left to grow in the device for an additional night and the measurements were then taken in a 10 minute interval during the next day. This was done for two reasons: for one the chamber had to be completely dried out before measurements could be taken, otherwise the remaining liquid would condense through the heat of the light and blur the pictures. The second reason was that - as mentioned before - [[Team:Wageningen_UR/Project/ModelingProj1#Preliminary_conclusions_for_our_system| our modeling]] suggested that - when applying no flow - the oscillations would only occur when starting with a high cell density. | ||
+ | |||
+ | |||
+ | |||
+ | [[Team:Wageningen_UR/Project/DevicesSetup#Custom fluidic device designed by Team Wageningen UR to measure oscillations| back to top]] | ||
+ | |||
+ | |||
+ | '''Links and references:''' | ||
- | [[ | + | [1][http://www.nature.com/nature/journal/v463/n7279/abs/nature08753.html Danino et al. 2010] |
}} | }} |
Latest revision as of 02:15, 22 September 2011