Team:Tokyo Tech/Projects/making-rain/GC-Assay

From 2011.igem.org

Revision as of 10:55, 4 October 2011 by Sisterbao (Talk | contribs)

Tokyo Tech 2011

Rain details

Method

In order to assay the amount of isoprene produced by our E.coli, we use the Gas chromatography-mass spectrometry (GC-MS, QP-2010, SHIMADZU, Japan) for measurement. The MS uses an electron ionization method and quadrupole. Analytes were separated using a nonpolar column (Rtx-1MS: Length 30m, ID 0.25mm film thickness 0.5µm, USA) working in a constant flow mode (2.99ml min-1). The temperature program was chosen as follows: 40℃ for 7 min, increase to 280℃ at rate of 10℃ min-1, 280℃ for 5 min. The mass spectrometer worked in SIM mode, m/z 67. The retention time of isoprene is very short (about 1.06-1.10 min). But thanks to MS, isoprene could be identified.


<Quantitative Analysis>

Method

We made dilution series (deluted 102,103,104,105,106,107 times) of liquid isoprene (Wako Pure Chemical Industries, Ltd, Japan) diluted in chloroform. The undiluted isoprene solution 1[µl] is 0.654[mg]. We injected diluted isoprene into GC-MS. We tried to draw a calibration curve (Fig.1).

We firstly made dilution series (diluted 102,103,104,105,106,107 times) of liquid isoprene (Wako Pure Chemical Industries, Ltd, Japan) diluted in chloroform. The undiluted isoprene solution 1[µl] is 0.654[mg]. We injected diluted isoprene into GC-MS, and draw a calibration curve (Fig.1)


Fig.1 - Calibration Data
Fig.1 Dilution series of liquid isoprene diluted in chloroform were injected into GC-MS. Let area be the vertical axis, and amount of isoprene itself ([mg]) the horizontal axis.
Table.1 various experiments: We sampled headspace gas of solvent including isoprene or LB media with E.coli or none.
number container solvent isoprene[mg] sampling[ml] Condition from dripping isoprene to sampling
1 15ml centrifuge tube None 6.54 15 room temperature, 20minutes
2 500ml flask Water 100ml 13.1 50 room temperature, 20minutes
3 500ml flask Water 100ml 13.1 50 37℃, 20minutes
4 500ml flask LB medium 100ml 13.1 50 37℃, 20minutes
5 500ml flask LB medium 100ml 0 50 37℃, culture, 6hours
6 500ml flask LB medium 100ml 0 50 37℃, 6hours + E.coli(LT-21)

Table.1 Different conditions that used in samples` headspace gas of solvent including isoprene or LB media with E.coli or none. The condition is from dripping to sampling.


As a result the peak area was about one thousandth of expectable area by calibration data at experiment No.1-4, drip isoprene. The peak area’s retention time was same as that of isoprene at experiment No.5 (no isoprene, LB medium only), though the area was much less than those of No.1-4.


Fig.3

Fig.3 Peak Area

We wondered whether the adsorbing material was saturated with isoprene at experiment No.1-4 and isoprene still existed in silicon tube at experiment No.5. So we considered that firstly the tube needed to be used only once and then thrown away. Secondly, Headspace gas of dilution series of liquid isoprene diluted in chloroform in water needed to be sampled