Team:ETH Zurich/Process/Microfluidics/Proof

From 2011.igem.org

(Difference between revisions)
(Results)
(Results)
Line 30: Line 30:
-
We quantified the fluorescence signal using a moving average of 80×80 pixel, which moved along the symmetry axis of the tube (see Figure 7), in red you can see the corresponding reaction diffusion model.  
+
We quantified the fluorescence signal using a moving average of 80×80 pixel, which moved along the symmetry axis of the tube (see Figure 5), in red you can see the corresponding reaction diffusion model.  

Revision as of 01:59, 29 October 2011

Can you feel the smoke tonight?
 

Contents

Proof of Concept

In this section we describe the proof of principle we performed to validate our system. The experiment was performed to see whether the diffusion-only design with agarose-immobilized cells in a channel (without flow) would work for the SmoColi system.

Experimental setup

Figure 1: Experimental setup for SmoColi, a tube with no flow, diffusion only

The model predicted that SmoColi would work in a system which is based on diffusion (without any flow). As experimental validation of the model predictions, we first performed GFP expression tests in a 2 mm diameter tube. For proof of concept, we engineered E. coli strain JM101 to express GFP upon IPTG induction. The cells then were immobilized in agarose and the suspension was added to the tube (see Figure 1). One end of the tube was connected to a resevoir (1.5 ml) containing 10 mM IPTG solution. After incubation at 37 °C overnight, an IPTG-inducible GFP gradient could be observed (Figure 4 and 5). The experiment confirmed the modeling results. Our cells survived and we concluded that we do not need constant supply of nutrients.

Because there is no flow needed in the setup, the whole design is rather simple compared to the ones where flow is included (Microfluidic Channel Design). Here, the whole channel can simply be filled with cell-agarose suspension. Upon solidification to a gel, the channel can be connected to a reservoir containing the inducer molecule on one side. Likewise we do not need recycling because AHL can diffuse through the whole channel and does not have to diffuse against a flow. Moreover, having a tube instead of a microfluidic device would save us some time that we would need otherwise for the channel construction.


Modeling the system thus had a profound effect on the process design, leading to an extensive reduction of complexity and error-proneness. Additionally, the AHL induced alarm system would be much easier to establish in a channel without flow.

Figure 2: Photo of the channel in action. The channel (the long thin tube at the right, 2 mm diameter, 7 cm length) is physically attached to a reservoir filled with the sample medium containing the toxic molecule, or in our test system with IPTG (the Eppendorf tube at the lower left). In the case of acetaldehyde, the whole setup would be packed in an impermeable plastic bag to significantly reduce the vaporization of acetaldehyde (not shown).
Figure 3: After the experiment, the agarose gel containing the cells is removed from the tubing. The bald interior of the channel is placed on a petri dish (see picture) and analyzed under a fluorescence microscope.


Results

Fluorescence pictures of the tube showed a clear gradient of the fluorescence signal over approximately 5 cm of the tube. After 5 cm, the signal strength dropped under the background noise.


Figure 4: GFP gradient in tube: E. coli strain JM101 with IPTG-inducible GFP was incubated in the tube. GFP expression was assessed under the fluorescent microscope after overnight incubation, with a excitation wavelength of 480 nm and a emission wavelength of 510 nm. The 15 microscope photos were reassembled into one using the Microsoft Research Image Composite Editor.


We quantified the fluorescence signal using a moving average of 80×80 pixel, which moved along the symmetry axis of the tube (see Figure 5), in red you can see the corresponding reaction diffusion model.


Figure 5: Quantification of the gradient in Figure 2: The light intensity of the IPTG-induced GFP signal was quantified by a 80×80 pixel moving average. The peak at around 1.2cm is due to an air bubble in the channel.


The fluorescence distribution of this experiment has a similar shape as the distributions predicted by the model (see modeling section). The difference in the experimental results compared to the simulations can be explained mainly due to the different diffusing molecules: the simulations were obtained for acetaldehyde, whereas the experiments were carried out with IPTG. We expect the different values of the diffusion as well as of the degradation constants of the two molecules to be the main reason for the differences.

Back to iGEM Our Sponsors
ETHZ-BASF.png ETH Zurich Logo.png ETHZ-Lonza.png ETHZ-Merck Serono.png
ETHZ-Novartis.png ETHZ-Roche.png ETHZ-Syngenta.png DSM MasterLogo.png