Team:Debrecen Hungary/Arsenic

From 2011.igem.org

Revision as of 21:49, 21 September 2011 by Lillu (Talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

Testing of arsenic biosensor

Background

Arsenic is a serious groundwater contaminant of major public health significance. During the 1970s, due to a high incidence of waterborne disease, millions of tube wells were drilled in Bangladesh to provide drinking water. Unfortunately, years later, many instances of ill health were found to be associated with consumption of this water, and it became apparent that many of the wells had inadvertently been drilled through arsenic bearing sediments and that the water was contaminated with arsenic in the form of arsenate and arsenite anions. Arsenic is a serious poison, and chronic consumption leads to arsenicosis, with symptoms such as skin lesions and cancers. The WHO limit for arsenic in drinking water is 10 ppb, though a more relaxed limit of 50 ppb is still in operation in many countries. Many wells exceed these limits. Similar contaminated groundwater has also been found to occur in many other countries, and one estimate suggests that 100 million people worldwide may be at risk. There is therefore a need for methods for testing and monitoring arsenic levels. Various highly accurate laboratory methods are available, but for large scale use in less developed regions, it would be preferable to have simple and cheap test kits which can be used in the field.

In 2006, Team Edinburgh have developed a genetically engineered machine which was able to detect arsenite/arsenate ions in water samples. They particitaped first time and won first prize in the Best Real World Application category.To see the part (BBa_33203) visit the Registry of Standard Biological Parts here: [1].

As the South-East of Hungary is highly affected by the arsenic problem (there are wells in which the level of arsenic exceeds the allowed limit), we had the possibility to use real-world samples for testing. The current situation of the arseinc problem in the drinking water of the south east region of Hungary can be found here: [2]

As the Edinburgh team tested the system only on distilled water samples spiked with sodium-arsenate, we contacted the team and offered our help to test the machine on real-world samples to prove that it works not only on artificial but on natural samples as well (with many different compounds that may interfere with the part's action). We also sent them twenty sterilized samples collected by a Local Public Health Organisation from different wells - this organisation has also provided data on arsenic concentrations gained from flame atomic absorption spectrometry measurements.