==Gel Extraction of DNA (Spin Column Extraction)==
==Gel Extraction of DNA (Spin Column Extraction)==
Line 6: Line 5:
===Theory===
===Theory===
-
Gel extraction or gel isolation is a technique used to isolate a desired fragment of intact DNA from an agarose gel following agarose gel electrophoresis. After extraction, fragments of interest can be mixed, precipitated, and enzymatically ligated together in several simple steps. This process is the basis for rudimentary genetic engineering.
+
Gel extraction or gel isolation is a technique used to isolate a desired fragment of intact DNA from an agarose gel following agarose gel electrophoresis. After extraction, fragments of interest can be mixed, precipitated, and enzymatically ligated together in several simple steps. This process forms the basis for rudimentary genetic engineering.
 +
===Practice===
 +
We used the QIAgen quick gel extraction kit, the protocol is adapted from the [http://openwetware.org/images/5/5e/QIAquick_Gel_Extraction_Kit_Protocol.pdf QIAquick Gel Extraction Kit Protocol].
-
After DNA samples are run on an agarose gel, extraction involves four basic steps:
+
*'''''Extraction From Gel'''''
-
<center>
+
:# The gel is exposed to blue-light to illuminate the DNA fragments(stained by SYBR safe dye).  
-
:#identifying the fragments of interest
+
:# The desired DNA band is identified and physically removed with a rectangular tipped pipette. The removed slice of gel contains the desired DNA.
-
:#isolating the corresponding bands
+
-
:#isolating the DNA from those bands
+
-
:#removing the accompanying salts and stain.
+
-
</center>
+
-
 
+
-
 
+
-
To begin, blue-light illumination is shone on the gel in order to illuminate all the DNA fragments(stained by SYBR safe dye). The desired band is identified and physically removed with pipette with a special rectangular pipette tip. The removed slice of gel should contain the desired DNA inside.
+
-
 
+
-
===Practice===
+
-
Used QIAgen quick gel extraction kit, the protocol is adapted from the QIAgen gel extraction protocol
+
-
[http://openwetware.org/images/5/5e/QIAquick_Gel_Extraction_Kit_Protocol.pdf QIAquick Gel Extraction Kit Protocol].
+
-
;Step 1
+
*'''''DNA Purification'''''
-
:Add 3 volumes of buffer QG to 1 volume of gel. E.g.add 300 µl of Buffer QG to each slice of gel (volume of the slice is 100 µl, and weight of the slice is approximately 100 mg).
+
:#Add 3 volumes of buffer QG to 1 volume of gel. E.g.add 300 &mu;l of Buffer QG to each slice of gel (volume of the slice is 100 &mu;l, and weighs approximately 100 mg).
-
;Step 2
+
:# Incubate at 50°C for 10 min (or until fully dissolved). To aid solvation, mix by vortexing the tube every 2–3 min during the incubation.  
-
: Incubate at 50°C for 10 min (or until the gel slice has completely dissolved). To help
+
:# After the gel slice has dissolved fully, check that the colour of the mixture is yellow (similar to Buffer QG without dissolved agarose).  
-
dissolve gel, mix by vortexing the tube every 2–3 min during the incubation.  
+
:# Add 1 gel volume of isopropanol to the sample and mix.  
-
;Step 3
+
:# Place a QIAquick spin column in a provided 2 ml collection tube.  
-
:After the gel slice has dissolved completely, check that the color of the mixture is
+
:# Apply each sample of DNA fragment to a QIAquick column, and centrifuge for 1 min at 13000 rpm.  
-
yellow (similar to Buffer QG without dissolved agarose).  
+
:# Discard flow-through and place QIAquick column back in the same collection tube. (Optional)
-
;Step 4
+
:# ('''Optional''') Add 0.5 ml of Buffer QG to QIAquick column and centrifuge for 1 min.
-
:Add 1 gel volume of isopropanol to the sample and mix.
+
:#*'''This step will remove all traces of agarose. It is only required when the DNA will subsequently be used for direct sequencing, in vitro transcription or microinjection.'''
-
;Step 5
+
:# To wash, add 0.75 ml of Buffer PE to QIAquick column and centrifuge for 1 min.
-
:Place a QIAquick spin column in a provided 2 ml collection tube.
+
:#* '''If this step is omitted, follow [[Team:Cambridge/Protocols/DNA Precipitation |Rescue Precipitation of DNA]]'''
-
;Step 6
+
:# Discard the flow-through and centrifuge the QIAquick column for an additional 1 min at ≥ 10,000 x g (~13,000 rpm).
-
:apply each sample of DNA fragment to a QIAquick column, and centrifuge for 1 min at 13000 rpm.
+
:#* '''IMPORTANT:''' '''Residual ethanol from Buffer PE will not be completely removed unless the flow-through is discarded before this additional centrifugation.'''
-
;Step 7
+
:# Place QIAquick column into a clean 1.5 ml microcentrifuge tube.  
-
:Discard flow-through and place QIAquick column back in the same collection tube.
+
:# To elute DNA, add 50 &mu;l of Buffer EB (10 mM Tris·Cl, pH 8.5) or H<sub>2</sub>O to the center of the QIAquick membrane and centrifuge the column for 1 min at 13000rpm. Alternatively, for increased DNA concentration, add 30 &mu;l elution buffer to the center of the QIAquick membrane, let the column stand for 1 min, and then centrifuge for 1 min.  
-
;Step 8
+
:#*'''IMPORTANT:''' '''Ensure that the elution buffer is dispensed directly onto the QIAquick membrane for complete elution of bound DNA.  
-
:(Optional): Add 0.5 ml of Buffer QG to QIAquick column and centrifuge for 1 min.
+
:#* '''The average eluate volume is 48 &mu;l from 50 &mu;l elution buffer volume, and 28 &mu;l from 30 &mu;l. Elution efficiency is dependent on pH. The maximum elution efficiency is achieved between pH 7.0 and 8.5. When using water, make sure that the pH value is within this range, and store DNA at –20°C as DNA may degrade in the absence of a buffering agent.'''
-
This step will remove all traces of agarose. It is only required when the DNA will
+
:#*'''The purified DNA can also be eluted in TE (10 mM Tris·Cl, 1 mM EDTA, pH 8.0), but the EDTA may inhibit subsequent enzymatic reactions.'''
-
subsequently be used for direct sequencing, in vitro transcription or microinjection.
+
-
;Step 9
+
-
:To wash, add 0.75 ml of Buffer PE to QIAquick column and centrifuge for 1 min.
+
-
;Step 10
+
-
:Discard the flow-through and centrifuge the QIAquick column for an additional 1 min
+
-
at ≥10,000 x g (~13,000 rpm).
+
-
IMPORTANT: Residual ethanol from Buffer PE will not be completely removed unless
+
-
the flow-through is discarded before this additional centrifugation.
+
-
;Step 11
+
-
:Place QIAquick column into a clean 1.5 ml microcentrifuge tube.
+
-
;Step 12
+
-
: To elute DNA, add 50 µl of Buffer EB (10 mM Tris·Cl, pH 8.5) or H2O to the center of the QIAquick membrane and centrifuge the column for 1 min at 13000rpm. Alternatively, for increased DNA concentration, add 30 µl elution buffer to the center of the QIAquick membrane, let the column stand for 1 min, and then centrifuge for 1 min.
+
-
'''''IMPORTANT:''''' Ensure that the elution buffer is dispensed directly onto the QIAquick membrane for complete elution of bound DNA. The average eluate volume is 48 µl from 50 µl elution buffer volume, and 28 µl from 30 µl. Elution efficiency is dependent on pH. The maximum elution efficiency is achieved between pH 7.0 and 8.5. When using water, make sure that the pH value is within this range, and store DNA at –20°C as DNA may degrade in the absence of a buffering agent. The purified DNA can also be eluted in TE (10 mM Tris·Cl, 1 mM EDTA, pH 8.0), but the EDTA may inhibit subsequent enzymatic reactions.
+
===Safety===
===Safety===
-
The safety implication of the procedure.
+
Since the agarose gel has been dyed with SYBR Safe, everything that could have come into contact with it needs to be treated as [https://2011.igem.org/Team:Cambridge/Safety#Waste_Disposal liquid hazardous waste], including gloves (which must be worn at all times during the whole procedure).  
-
{{Template:Team:Cambridge/CAM_2011_TEMPLATE_FOOT}}
+
{{Template:Team:Cambridge/CAM_2011_PROTOCOL_FOOT}}

Latest revision as of 20:20, 21 September 2011

Loading...
OVERVIEW
home
Back to Protocols

Contents

Gel Extraction of DNA (Spin Column Extraction)

A technique used to isolate a desired fragment of intact DNA from an agarose gel following agarose gel electrophoresis

Theory

Gel extraction or gel isolation is a technique used to isolate a desired fragment of intact DNA from an agarose gel following agarose gel electrophoresis. After extraction, fragments of interest can be mixed, precipitated, and enzymatically ligated together in several simple steps. This process forms the basis for rudimentary genetic engineering.

Practice

We used the QIAgen quick gel extraction kit, the protocol is adapted from the [http://openwetware.org/images/5/5e/QIAquick_Gel_Extraction_Kit_Protocol.pdf QIAquick Gel Extraction Kit Protocol].

  • Extraction From Gel
  1. The gel is exposed to blue-light to illuminate the DNA fragments(stained by SYBR safe dye).
  2. The desired DNA band is identified and physically removed with a rectangular tipped pipette. The removed slice of gel contains the desired DNA.
  • DNA Purification
  1. Add 3 volumes of buffer QG to 1 volume of gel. E.g.add 300 μl of Buffer QG to each slice of gel (volume of the slice is 100 μl, and weighs approximately 100 mg).
  2. Incubate at 50°C for 10 min (or until fully dissolved). To aid solvation, mix by vortexing the tube every 2–3 min during the incubation.
  3. After the gel slice has dissolved fully, check that the colour of the mixture is yellow (similar to Buffer QG without dissolved agarose).
  4. Add 1 gel volume of isopropanol to the sample and mix.
  5. Place a QIAquick spin column in a provided 2 ml collection tube.
  6. Apply each sample of DNA fragment to a QIAquick column, and centrifuge for 1 min at 13000 rpm.
  7. Discard flow-through and place QIAquick column back in the same collection tube. (Optional)
  8. (Optional) Add 0.5 ml of Buffer QG to QIAquick column and centrifuge for 1 min.
    • This step will remove all traces of agarose. It is only required when the DNA will subsequently be used for direct sequencing, in vitro transcription or microinjection.
  9. To wash, add 0.75 ml of Buffer PE to QIAquick column and centrifuge for 1 min.
  10. Discard the flow-through and centrifuge the QIAquick column for an additional 1 min at ≥ 10,000 x g (~13,000 rpm).
    • IMPORTANT: Residual ethanol from Buffer PE will not be completely removed unless the flow-through is discarded before this additional centrifugation.
  11. Place QIAquick column into a clean 1.5 ml microcentrifuge tube.
  12. To elute DNA, add 50 μl of Buffer EB (10 mM Tris·Cl, pH 8.5) or H2O to the center of the QIAquick membrane and centrifuge the column for 1 min at 13000rpm. Alternatively, for increased DNA concentration, add 30 μl elution buffer to the center of the QIAquick membrane, let the column stand for 1 min, and then centrifuge for 1 min.
    • IMPORTANT: Ensure that the elution buffer is dispensed directly onto the QIAquick membrane for complete elution of bound DNA.
    • The average eluate volume is 48 μl from 50 μl elution buffer volume, and 28 μl from 30 μl. Elution efficiency is dependent on pH. The maximum elution efficiency is achieved between pH 7.0 and 8.5. When using water, make sure that the pH value is within this range, and store DNA at –20°C as DNA may degrade in the absence of a buffering agent.
    • The purified DNA can also be eluted in TE (10 mM Tris·Cl, 1 mM EDTA, pH 8.0), but the EDTA may inhibit subsequent enzymatic reactions.

Safety

Since the agarose gel has been dyed with SYBR Safe, everything that could have come into contact with it needs to be treated as liquid hazardous waste, including gloves (which must be worn at all times during the whole procedure).

Back to Protocols